- Includes soft catheter, rigid tubing and 2 bottles. - OEM/ODM request are welcome.
Made of stainless steel .
With handle steel.
Self adhesive with absorbent pad
Silicone gel breast implant Any size, high profile, textured
GK(F) series is the vertical centrifuge funning continuously but discharging intermittently. PLC system is adopted in the centrifuge so stepless speed regulation and electric braking can be realized in braking system by frequency-conversion speed regulation. Automatic cycle operation can be finished in whole process by material level detection, revolving speed inspection and vibration monitoring (including the process such as: feeding, separation and dehydration, washing discharging and net washing etc.). Manual control and operation can also as adopted. In addition to medium and fine grains. GK(F) Series Automatic Horizontal Scraper Centrifuge can also be applied in the solid-liquid separation such as: fine grains, low filter velocity material, poisonous, harmful, flammable and explosive materials. Therefore, it is widely used for solid-liquid separation of pharmacy., food, chemical industry and national defense Model GK(F)-800 GK(F)-1050 GK(F)-1250 GK(F)-1250A GK(F)-1600 Drum diameter (mm) 800 1050 1250 1250 1600 Drum height (mm) 400 500 500 630 650 Drum volumn (L) 90 210 250 300 600 Loading capacity(KG ) 120 230 300 400 750 Drum speed (r/min) 1500/1600 1400 1200 1200 950 Maximum separating factor 1007/1145 1150 1006 1006 808 Motor power (kw) 30 37 55 55 90 Motor speed (r/min ) 1450 1450 1450 1450 1450 Size (mm ) 2043í-1625í-1394 3100í-1700í-1500 3640í-1800í-1980 2940í-2000í-2170 2476í-2235í-2116 2476í-2235í-2116 2624í-2800í-2516 Weight (kg) 3200 3400 6800 7600 9600
Model GK(F)-800 GK(F)-1050 GK(F)-1250 GK(F)-1250A GK(F)-1600 The diameter of drumú¿mmú¬ 800 1050 1250 1250 1600 The height of drum ú¿mmú¬ 400 500 500 630 650 the capacity of drum ú¿Lú¬ 90 210 250 300 600 loading (KG) 120 230 300 400 750 revolving speed of drumú¿r/minú¬ 1500/1600 1400 1200 1200 950 the maximum seperating factor 1007/1145 1150 1006 1006 808 motor powerú¿Kwú¬ 30 37 55 55 90 revolving speed of motorú¿r/minú¬ 1450 1450 1450 1450 1450 Overall dimensionú¿mmú¬ 2043í-1625í-1394 3100í-1700í-1500 3640í-1800í-1980 2940í-2000í-2170 2476í-2235í-2116 2476í-2235í-2116 2624í-2800í-2516 Weightú¿Kgú 3200 3400 6800 7600 9600
Sdq electrolysis equipment Product characteristic Technical specification Product diagram After-gas process equipment Hydrogen purifier Specific power generator hydrogen deliquefaction Atmospheric pressure hydrogen recycling purifier Atmospheric pressure chloro alcali waste Steel facility hydrogen recycling purifier Compress-type electrolysis equipment
Product Description: SANLI blood collection needle for single use Product Specification/Models: blood collection set Size: 18G,20G,21G,22G,23G,24G,25G Color: pink, yellow, green, black, blue, orange Holder for Multi-sample needle 20mm*55mm Holder for butterfly needle 19mm*53mm Other Information: We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples. Certificate: CE Payment: L/C, T/T, Cash Delivery: DHL , TNT ,EMS Origin: HUNAN LIUYANG Minimum Order: 100000 Packaging: 6000/BOX Samples: Free Sample Price: US$0 Remarks: We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples. 100pcs/tray 4000pcs/carton
EPGT tube stands on EDTAK2 with Gel Tube. It is coated with lithium heparin and inside the tube a barrier Gel presented at the bottom. Product Feature they are normally made of glass and plastic. In addition, the plastic tube includes PET, PP and PS. Product Specification/Models 1ml 13í-75mm VP10041S 2ml VP20031S 3ml VP30031S 4ml 13í-100mm VP40042S 5ml VP50032S 6ml VP60032S 8ml 16í-100mm VP80043S 9ml VP90043S Application. Through centrifugation, the separation gel can form a barrier between plasma and blood cell and totally separate them. Clinical specimen obtained is suitable for analysis of virus capacity and molecular diagnostics of undiluted plasms. Other Information We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples. 100pcs/tray 1200pcs/carton
Product feature They are normally made of glass and plastic. In addition, the plastic tube includes pet , pp and ps. Product specification/models 3ml 13íß75mm vp30011s 4ml vp40011s 5ml vp50011s 3ml 13íß100mmvp30012s 4ml vp40012s 5ml vp50012s 6ml vp60012s 8ml 16íß100mmvp80013s 9ml vp90013s Application It is used for collecting blood specimen for biochemistry and immunology tests, especially fast in blood coagulation. Other information We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples. 100pcs/tray 1200pcs/carton
Ssgt tube stands on clot activator with gel tube. It is coated with clot activator and inside the tube a barrier gel presented at the bottom. Product feature They are normally made of glass and plastic. In addition, the plastic tube includes pet, pp and ps. Product specification/models 3ml 13íß75mm vp30021s 3.5ml vp35021s 3ml 13íß100mm vp30022s 4ml vp40022s 5ml vp50022s 7ml 16íß100mm vp70023s 8ml vp80023s Application It is used for clinical biochemistry and immunology. The obvious characteristic of ssgt tube is used to obtain high-quality plasma specimen for medical laboratories. Other information We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples. 100pcs/tray 1200pcs/carton
Product specification/models Infant blood collection tube: 8*45mm Color: red, yellow, lavender, green, black, gray, blue. Application It's used for children's blood collection Other information We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples. 100pcs/tray 1200pcs/carton
Diagnostic set Standard packing: Each set packed in wooden box
S350 Zeiss type Slit Lamps(3 or 5 magnifictaions) With CE and ISO13485 marks MICROSCOPE Type: Galilean optical system Configuration: Zeiss type Eyepiece: 12.5x Angle between eyepieces: 13 degree binocular tube with converging optics Magnification change: 3 or 5 steps by revolving drum Total magnification and field of view (mm): 10X (22), 16X (13.5), 25X (8.5) / 6X (34.7), 40 X (5.5) Pupilary adjustment: 55mm~78.5mm Diopter adjustment: -6d~+6d Slit illumination Slit width: Continuous from 14mm to 0mm(at 14mm, slit becomes a circle) Slit length: Continuous from 14mm to 1mm(at 14mm, slit becomes a circle) Slit angle: 0 to 180 degree(continuously adjustable both vertical and horizontal) Aperture diameters: 14mm, 8mm, 3.5mm, 0.5mm Filter:Thermal safety, Cobalt Blue, Red-free Lamp: German imported 6v, 20w halogen lamp(OSRAM) or LED lamp. Accessories: Applanation Tonometer, Beam Splitter, DC Adaptor, DC, Video Camera Adaptor, Video Camera, Teaching Tube, etc... Yellow Filter, Amber Filter and Measuring Eyepiece are available. TRIPLE WALL CORRUGATED FIBREBOARD BOXES Gross Weight:22KGS Net Weight:20KGS Dimension:740mm X 450mm X 500mm
S350 haag-streit type slit lamps (3 or 5 magnifictaions) With ce and iso13485 marks Microscope Type: galilean optic system Configuration: haag-streit type Eyepiece: 12.5x Angle between eyepieces: 13 degree binocular tube with converging optics Magnification change: 3 or 5 steps by revolving drum Total magnification and field of view (mm): 10x (22), 16x (13.5), 25x (8.5) / 6x (34.7), 40 x (5.5) Pupilary adjustment: 55mm~78.5mm Diopter adjustment: -6d~+6d Slit illumination Slit width: continuous from 14mm to 0mm (at 14mm, slit becomes a circle) Slit length: continuous from 14mm to 1mm (at 14mm, slit becomes a circle) Slit angle: 0 to 180 degree(continuously adjustable both vertical and horizontal) Aperture diameters: 14mm, 10mm, 5mm, 3mm, 2mm, 1mm, 0.2mm Filter: thermal safety, uv, cobalt blue, red-free Slit inclination 4 steps: 5 degree, 10 degree, 15 degree, 20 degree Lamp: german imported 6v, 20w halogen lamp (osram) or led lamp. Accessories: applanation tonometer, beam splitter, dc adaptor, dc, video camera adaptor, video camera, teaching tube, etc... Yellow filter, amber filter and measuring eyepiece are available. Triple wall corrugated fibreboard boxes Gross weight:25kgs Net weight:24kgs Dimension:740mm x 450mm x 500mm
Features: Small & lightweight design ( total 28g without batteries ) Digital LEDs display Display SpO2,PR,Pulse bar Low power consumption Automatically power off Battery-low indicator 2 AAA alkaline or rechargeable batteries Accommodates widest range of finger sizes from pediatric to adult Standard Accessory 2 AAA Alkaline batteries Operating manual Hang string
Technical Parameters Display Mode : double Color OLED display SPO2 measuring range: 35-100% Pulse Ratio:30-240 BPM Pulse Waveform display: bargraph display Battery indication: OLED display Power Requirements: 1.5V(A A A size )Alkali Batteriesí-2 Adaptable range:2.6V-3.6V Working current:í_20mA Resolution: SPO2 : 1% Pulse Rate: 1bpm Accuracy: SPO2 :70% to 100% í+2digits,below 70% unspecified Pulse rate:í+2bpm or í+ 2%(select larger) Measurement at Low Perfusion: The values of SPO2 and pulse rate can be displayed properly when pulse saturation is at 0.4%. Accuracy of SPO2:í+4% Accuracy of Pulse Ratio.í+2BPM or í+2% (Select Larger) Resistance to surrounding light: Deviation is smaller than í+1% between value of Oxyhemoglobin measured in natural lighting indoor condition and present lighting sources and that measured in dark room. Automatic shutdown function: The device will power off automatically within 5 seconds when there is no finger in the device. When working, the display direction can be changed by pressing the button shortly. There are six modes of direction. In working term, long press can change the lighteness of the screen.
Technical Parameter: Display Format: LCD SPO2:35-99% Pulse Ratio:30-255 BPM Pulse Wave: LCD Numeric Display Battery Voltage Low Indication: LCD Bar Graph. Power Requirements: Two AAA size 1.5V Alkaline Batteries Power Consumption: less than 15 mA. Resolution: 1% for SPO2 and 1 BPM for Pulse Rate. Measurement Accuracy: í+2% in stage of 70%-99% for SPO2 Unspecified in stage of 35-69% for SPO2 í+2BPM or í+2%(Select Larger)for Pulse Rate. Measurement Performance in Low Perfusion: SPO2 and pulse & rate can be shown correctly when pulse-perfusion ratio is 0.4% Interference Resistance Capacity against Ambient Light : Deviation is smaller than í+1% It is equipped with a function switch, through which the Oximeter can be automatically powered off when no finger is in the Oximeter more than 4 seconds
LCD display with backlight, can be used in any illumination conditions. DSP technology is employed to assure accuracy and reliability of FHR detection. High sensitivity probe with 1 MHz in pulse (Option: 2.0MHz in continuous wave). Ergonomic design, portable and convenient. Built_in speaker and Sound frequency output port. Automatically power off; Multi_displaying of FHR: number, battery status indicator, voice intensity indicator; Three working modes:Real_time FHR display, Mean FHR display and Manual counting display.(Option:2.0MHz)