Applications
1. CATV
2. Metro
3. Test equipment
4. Active device termination
5. Local area networks (lans)
6. Premise installations
7. Telecommunication networks
8. Data processing networks
9. Wide area networks (wans)
Features
1. Low insertion loss and high reflection loss
2. Good durability
3. Compliant standard: IEC & ROHS
4. Good exchangeability
5. High temperature stability
6. Customization, I. E.: print company name on the connector and adapter.
200 piece per carton,
0.0587 cbm per carton
12kg per carton.
Features:
1. FTTH project usable
2. Field installable
3. Fast, easy, accurate
4. Cost effective
5. Portable
6. Installation less than 2 minutes
7. Reliable and superior optical performance
8. Cable Tensile test complies with Telcordia GR-326-CORE
Application:
1. Distribution frames
2. Maintenance or emergency restoration of fiber networks
3. Patch panels
4. FTTH Outlets
5. Field word.
Features:
Uitra-end insertion loss and associated loss of polarization
Goodspectral uniformity
Wide wavelength bandwidth
A wide range of working environment
High reliability
Small size
Applications:
Can be widely used for FTTX
Passive Optical Network (OPN)
Cable TV Network (CATV)
Other optical signal splitter system
Standard compliance:
Telcordia GR-1209-CORE
Telcordia GR-1221-CORE
YD/T1117-2001
BV electirc cable (60227 IEC 05)
1) Conductor: Copper (70¡ã C single core solid)
2) Insulation: PVC
3) Sheathed: Non
4) Rated voltage (U0/U): 300/500V
5) Standard: IEC60227-2003 or as per the customers' requests
6) Purpose: For internal wiring
7) The max continuous operating temperature of the conductor: 70¡ã C
8) The ambient temperature for the cable installation: 0¡ã C
9) The bending radius of the cable: (D=cable outer diameter, R=bending radius)
A. D 25mm, R 4D
B. D>25mm, R 6D"
10) Specifications & Technical Data :
Nominal
cross-
section Con-
ductor
Type Insulation
Thickness Average
Overall
Diameter Approx
Weight Max
Conductor
Resistance
¦¸ /km Min
Insulation
Resistance
mm 2 mm mm kg/km without
coat metal
coat M¦¸ /km
0.5 1 0.6 2.4 8.08 36 36.7 0.015
0.75 1 0.6 2.6 10.55 24.5 24.8 0.012
1 1 0.6 2.8 13.28 18.1 18.2 0.011
HS Code: 8544492100
Productivity: 600km/Month
Unit Price: Negotiable
Shipment Terms: FOB
Payment Terms: L/C,T/T,negotiation
Minimum Order: 1000 Meter
Price Valid Time: From Jan 09,2012 To Jan 09,2013
Insulation Material: PVC
Conductor Type: Stranded
Conductor Material: Copper
Application: Inner House Wiring
Type: Insulated
Export Markets: North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe.
100m/roll 3roll/bags.
2087 Optical Fiber Cables Suppliers
Short on time? Let Optical Fiber Cables sellers contact you.
Control :by technician
Needed air :10.5 bar 12 m³/min.(duct 40 hdp)
Air engine : double effective, 740 watt (2 pieces)
Needed air for engines : 6 bar-1.6m³/min.
Cable installing velocity : 0, 30, 50m/min.
Lay down power :80~85 kg.
Dimensions (width x lenght x height) : 365mm x 330mm x 540mm
Weight of machine :46kg.
3. Jacket:
Material: PVC
Thickness: average:0.50mm Min. at any point:0.40mm
Diameter: 6.3,0.3mm
Color: to your option
Elongation rate: Min.125%
Tensile strength: Min.1.41kg/mm2
4. Rip cord& meter mark: optional
5. Standards: CE, CB,CE,ROHS, ISO 9001:2000,IEC
Application:
1) Data transmission cable for structure laying electric wires
2) For figure, voice, data and video signal transmission
3) Suitable for all of D-level lines and Cat6 application
4) ISDN, 10M Ethernet, 100M speed Ethernet, KM Ethernet, 4/16Mbit/s Token-Ring,
TP-PMD/TP-DDI 125Mbit/s, ATM 155Mbit/s.
3. Jacket
Material: PVC
Thickness: average:0.50mm Min. at any point:0.40mm
Diameter: 6.30.3mm
Color: to your option
Elongation rate: Min.125%
Tensile strength: Min.1.41kg/mm2
4. Rip cord& meter mark: optional
5. Standards: CE, CB,CE,ROHS, ISO 9001:2000,IEC
Application:
1) Data transmission cable for structure laying electric wires
2) For figure, voice, data and video signal transmission
3) Suitable for all of D-level lines and Cat6 application
4) ISDN, 10M Ethernet, 100M speed Ethernet, KM Ethernet, 4/16Mbit/s Token-Ring,
TP-PMD/TP-DDI 125Mbit/s, ATM 155Mbit/s.
Conductor: Plain annealed flexible copper complying with BS6360, class 5
Insulation: PVC (polyvinyl chloride)
Outer sheath: PVC (polyvinyl chloride). Color: Grey
Voltage Range: 300/500 volts, Test 3000 volts
Core Identification: Black cores with white numbers with green/yellow core.
Operating temperature:- 20° C to + 70° C in fixed condition,
- 5° C to + 70° C in mobile condition.
Bending Radius:10 x Overall Diameter.
The type flexible control cable, sometimes referred to as PVC/PVC control cable is ideal in fixed and mobile conditions. For use as a measuring, control and signal cable for the machine tool industry, plant construction, heating and air conditioning.
Conductor: Bare stranded copper, IEC 60228, Class 5.
Insulation: PVC (polyvinyl chloride)
Outer sheath: PVC (polyvinyl chloride).
Screen: Polyester tape, TWCB (Tinned Wire Copper Braid)
Operating temperature: - 40° C to + 70° C in fixed condition, - 15° C to + 70° C in mobile condition.
Bending Radius:15 x Overall Diameter.
Flexible data transmission control cable with a Tinned Copper Wire Braid (TWCB). Used in electronic control systems, in voice frequency, signal and data transmission. LiYCY (CY) can be used as a connection cable in office machinery and measurement devices. Suitable for fixed and flexible applications with unrestricted mobility, without forced movement control and without exposure to tensile load. Because these cables have a copper screening they are ideally suitable for interference free transmissions.
Voltage rating: 300/500V
Application:For industrial and wiring installation in air or in cable management systems, embedded in masonry or cement. Not suitable for laying in ground.
Construction:Solid or stranded plain copper conductors to VDE0295. PVC insulation, PVC sheath.
Insulation colours: Three Core: Green/Yellow, Blue, Brown.
Sheath colour: Grey
Minimum bending radius: 4D
Maximum conductor temperature: 70C.
Application:
Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
Standards:
Generally to BS6500, VDE0250
Conductor: Class 5 flexible plain copper conductors
Insulation and sheath: PVC (Polyvinyl Chloride)
Sheath Colour: Grey
Voltage Rating: 300/500V
Temperature Rating:Fixed: -35C to + 70CFlexing: -5C to + 70C
Minimum Bending Radius:10 x overall diameter
Core Identification:
Black with White numbers. (3 cores and above to include Green/Yellow). Coloured cores available.
RoHS Compliant.
Technical Information
Voltage Working : 300 / 500V to BS7919 & BS6500
Temperature range : Flexing : -25oC to +60oC
Static : - 40oC to + 60oC
Bending radius Flexing : 15 x cable diameter
Static : 6 x cable diameter
Stranding of fine copper wires plain or tinned
Rubber insulation :Colored cores acc. to VDE 0293
More than 2 cores with one green / yellow earth conductor.
Conductor Identification:
Two Core - Brown and Blue
Three Core - Brown, Blue and Green / Yellow
Four Core - Brown, Grey, Black and Green / Yellow
Five Core - Brown, Blue, Grey, Black and Green / Yellow
Application of H05RR-F: For connection of electrical appliances when exposed to low mechanical strain in household, offices and for light utilities. Anywhere where there is minimal physical damage expected.
PVC Insulated & Sheathed Power Cables
Standards: IEC60502, GB/T12706-2008
Application: It is suitable to be installed in duct, tray or direct burial, with rated voltage of U0/U (0.6/1KV) for transmitting electricity.
Service Conditions:
1. Regular nominal cross-sectional areas: 1.5 mm2, 2.5 mm2, 4 mm2, 6 mm2, 10 mm2, 16 mm2, 25 mm2, 35 mm2, 50 mm2, 70 mm2, 95 mm2, 120 mm2, 150 mm2, 185 mm2, 240 mm2, 300 mm2, 400 mm2, 500 mm2, 630 mm2, 800 mm2, 1000 mm2, 1200 mm2
2. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will not be affected by eciencies in the installation.
1, Use:
Aluminum wire and ACSRs structures are simple. They are easy to set up and maintenance. The cost is low in building the lines. The transmission capacity is large. They are also convenient to cross special geographical conditions, such as rivers, valleys and so on. So the products are applied for various voltage levels of overhead transmission and distribution lines.
1.Standard:GB5023.6-2006 IEC60227-6:2001
2.Fire worked stranded bared copper wires or tinned coppr wires
3.PVC jacket and insulator
4.Passed national complusory.
1.Standard:GB5023.6-2006 IEC60227-6:2001
2.Fire worked stranded bared copper wires or tinned coppr wires
3.PVC jacket and insulator
4.Passed national complusory .
500metres /rool, in drum.
2087 Optical Fiber Cables Suppliers
Short on time? Let Optical Fiber Cables sellers contact you.