Fiber patch cord Fiber optic accessories.
Bulk fiber cables Panels and connectivity Assemblies and patch cables.
Model: gztgl-12 Fiber diameter: 10.0mm Fiber material: pmma Cable diameter: 12.0mm Cable material: transparent pvc Solid core side glow cable is produced by jacketing with transparent pvc cover for uv protection. 100m/spool
Fiber optic patch cord Applications 1. CATV 2. Metro 3. Test equipment 4. Active device termination 5. Local area networks (lans) 6. Premise installations 7. Telecommunication networks 8. Data processing networks 9. Wide area networks (wans) Features 1. Low insertion loss and high reflection loss 2. Good durability 3. Compliant standard: IEC & ROHS 4. Good exchangeability 5. High temperature stability 6. Customization, I. E.: print company name on the connector and adapter. 200 piece per carton, 0.0587 cbm per carton 12kg per carton.
Features: 1. FTTH project usable 2. Field installable 3. Fast, easy, accurate 4. Cost effective 5. Portable 6. Installation less than 2 minutes 7. Reliable and superior optical performance 8. Cable Tensile test complies with Telcordia GR-326-CORE Application: 1. Distribution frames 2. Maintenance or emergency restoration of fiber networks 3. Patch panels 4. FTTH Outlets 5. Field word.
Features: Uitra-end insertion loss and associated loss of polarization Goodspectral uniformity Wide wavelength bandwidth A wide range of working environment High reliability Small size Applications: Can be widely used for FTTX Passive Optical Network (OPN) Cable TV Network (CATV) Other optical signal splitter system Standard compliance: Telcordia GR-1209-CORE Telcordia GR-1221-CORE YD/T1117-2001 Performance Index Type Unit 1 X 2 1 X 4 1 X 8 1 X 16 1 X 32 1 X 64 Optical Fiber diameter um 9/125 um¡¨º¡¡ìsmf-28¡¨º© wavelength nm 1260~1620 Insertion Loss dB ¡¨º¼3.8 ¡¨º¼7.3 ¡¨º¼10.6 ¡¨º¼13.7 ¡¨º¼16.9 ¡¨º¼21 Uniformity dB ¡¨º¼0.6 ¡¨º¼0.8 ¡¨º¼1.0 ¡¨º¼1.4 ¡¨º¼1.6 ¡¨º¼1.9 PDL Loss dB ¡¨º¼0.20 ¡¨º¼0.20 ¡¨º¼0.30 ¡¨º¼0.30 ¡¨º¼0.30 ¡¨º¼0.35 Directivity dB ¡¨º¾55 Return Loss dB ¡¨º¾50 Operation Temperature ¡æ -40~ +85 Storage Temperature ¡æ -40 ~ +85 Type Unit 2X 2 2 X 4 2 X 8 2X 16 2 X 32 2 X 64. ABS box.
BV electirc cable (60227 IEC 05) 1) Conductor: Copper (70¡ã C single core solid) 2) Insulation: PVC 3) Sheathed: Non 4) Rated voltage (U0/U): 300/500V 5) Standard: IEC60227-2003 or as per the customers' requests 6) Purpose: For internal wiring 7) The max continuous operating temperature of the conductor: 70¡ã C 8) The ambient temperature for the cable installation: 0¡ã C 9) The bending radius of the cable: (D=cable outer diameter, R=bending radius) A. D 25mm, R 4D B. D>25mm, R 6D" 10) Specifications & Technical Data : Nominal cross- section Con- ductor Type Insulation Thickness Average Overall Diameter Approx Weight Max Conductor Resistance ¦¸ /km Min Insulation Resistance mm 2 mm mm kg/km without coat metal coat M¦¸ /km 0.5 1 0.6 2.4 8.08 36 36.7 0.015 0.75 1 0.6 2.6 10.55 24.5 24.8 0.012 1 1 0.6 2.8 13.28 18.1 18.2 0.011 HS Code: 8544492100 Productivity: 600km/Month Unit Price: Negotiable Shipment Terms: FOB Payment Terms: L/C,T/T,negotiation Minimum Order: 1000 Meter Price Valid Time: From Jan 09,2012 To Jan 09,2013 Insulation Material: PVC Conductor Type: Stranded Conductor Material: Copper Application: Inner House Wiring Type: Insulated Export Markets: North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe. 100m/roll 3roll/bags.
Control :by technician Needed air :10.5 bar 12 m³/min.(duct 40 hdp) Air engine : double effective, 740 watt (2 pieces) Needed air for engines : 6 bar-1.6m³/min. Cable installing velocity : 0, 30, 50m/min. Lay down power :80~85 kg. Dimensions (width x lenght x height) : 365mm x 330mm x 540mm Weight of machine :46kg. In chrome box.
Specifications: 1) UTP Cat5, Cat5e cable, utp Cat6 cables are available 2) CCC,CE,CB,RoHS approved 3) Sale in Asia,Europe,Africa etc Structure: 1. Conductor: Material: solid or stranded copper Diameter: 23AWG Construction 1/0.57,0.02mm 2. Insulation: Material: HDPE Thickness: 0.24,0.05mm Diameter: 1.04,0.06mm Color: optional Elongation rate: Min.300% Tensile strength: Min.1.22kg/mm2 3. Jacket: Material: PVC Thickness: average:0.50mm Min. at any point:0.40mm Diameter: 6.3,0.3mm Color: to your option Elongation rate: Min.125% Tensile strength: Min.1.41kg/mm2 4. Rip cord& meter mark: optional 5. Standards: CE, CB,CE,ROHS, ISO 9001:2000,IEC Application: 1) Data transmission cable for structure laying electric wires 2) For figure, voice, data and video signal transmission 3) Suitable for all of D-level lines and Cat6 application 4) ISDN, 10M Ethernet, 100M speed Ethernet, KM Ethernet, 4/16Mbit/s Token-Ring, TP-PMD/TP-DDI 125Mbit/s, ATM 155Mbit/s. Carton.
Specifications: 1) Utp Cat5, Cat5e cable, utp Cat6 cables are available. 2) CCC, CE, CB, RoHS approved. 3) Sale in Asia,Europe,Africa etc. Structure: 1. Conductor: Material: solid or stranded copper Diameter: 23AWG Construction 1/0.570.02mm 2. Insulation: Material: HDPE Thickness: 0.240.05mm Diameter: 1.040.06mm Color: optional Elongation rate: Min.300% Tensile strength: Min.1.22kg/mm2 3. Jacket Material: PVC Thickness: average:0.50mm Min. at any point:0.40mm Diameter: 6.30.3mm Color: to your option Elongation rate: Min.125% Tensile strength: Min.1.41kg/mm2 4. Rip cord& meter mark: optional 5. Standards: CE, CB,CE,ROHS, ISO 9001:2000,IEC Application: 1) Data transmission cable for structure laying electric wires 2) For figure, voice, data and video signal transmission 3) Suitable for all of D-level lines and Cat6 application 4) ISDN, 10M Ethernet, 100M speed Ethernet, KM Ethernet, 4/16Mbit/s Token-Ring, TP-PMD/TP-DDI 125Mbit/s, ATM 155Mbit/s. Standard Lot Size
Conductor: Plain annealed flexible copper complying with BS6360, class 5 Insulation: PVC (polyvinyl chloride) Outer sheath: PVC (polyvinyl chloride). Color: Grey Voltage Range: 300/500 volts, Test 3000 volts Core Identification: Black cores with white numbers with green/yellow core. Operating temperature:- 20° C to + 70° C in fixed condition, - 5° C to + 70° C in mobile condition. Bending Radius:10 x Overall Diameter. The type flexible control cable, sometimes referred to as PVC/PVC control cable is ideal in fixed and mobile conditions. For use as a measuring, control and signal cable for the machine tool industry, plant construction, heating and air conditioning. 100m/roll.
Conductor: Bare stranded copper, IEC 60228, Class 5. Insulation: PVC (polyvinyl chloride) Outer sheath: PVC (polyvinyl chloride). Screen: Polyester tape, TWCB (Tinned Wire Copper Braid) Operating temperature: - 40° C to + 70° C in fixed condition, - 15° C to + 70° C in mobile condition. Bending Radius:15 x Overall Diameter. Flexible data transmission control cable with a Tinned Copper Wire Braid (TWCB). Used in electronic control systems, in voice frequency, signal and data transmission. LiYCY (CY) can be used as a connection cable in office machinery and measurement devices. Suitable for fixed and flexible applications with unrestricted mobility, without forced movement control and without exposure to tensile load. Because these cables have a copper screening they are ideally suitable for interference free transmissions. 100m/roll.
Voltage rating: 300/500V Application:For industrial and wiring installation in air or in cable management systems, embedded in masonry or cement. Not suitable for laying in ground. Construction:Solid or stranded plain copper conductors to VDE0295. PVC insulation, PVC sheath. Insulation colours: Three Core: Green/Yellow, Blue, Brown. Sheath colour: Grey Minimum bending radius: 4D Maximum conductor temperature: 70C. 100m/roll, roll in carton.
Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors. Standards: Generally to BS6500, VDE0250 Conductor: Class 5 flexible plain copper conductors Insulation and sheath: PVC (Polyvinyl Chloride) Sheath Colour: Grey Voltage Rating: 300/500V Temperature Rating:Fixed: -35C to + 70CFlexing: -5C to + 70C Minimum Bending Radius:10 x overall diameter Core Identification: Black with White numbers. (3 cores and above to include Green/Yellow). Coloured cores available. RoHS Compliant. 100m/roll.
Technical Information Voltage Working : 300 / 500V to BS7919 & BS6500 Temperature range : Flexing : -25oC to +60oC Static : - 40oC to + 60oC Bending radius Flexing : 15 x cable diameter Static : 6 x cable diameter Stranding of fine copper wires plain or tinned Rubber insulation :Colored cores acc. to VDE 0293 More than 2 cores with one green / yellow earth conductor. Conductor Identification: Two Core - Brown and Blue Three Core - Brown, Blue and Green / Yellow Four Core - Brown, Grey, Black and Green / Yellow Five Core - Brown, Blue, Grey, Black and Green / Yellow Application of H05RR-F: For connection of electrical appliances when exposed to low mechanical strain in household, offices and for light utilities. Anywhere where there is minimal physical damage expected. 100m/roll.
XLPE Cable, PVC Cable, Copper Cable, ABC Cable, AAC and ACSR Conductors. Packed in various sizes/weight of wooden/steel drums.
Fiber optical cable. Tray 100 100 pcs 13.5*27*3 cm Inner box 20 tray/box 2000 pcs 29*29*22 cm Outer box 2 inner box/outer box 4000 pcs 60*31*25.8 cm.
PVC Insulated & Sheathed Power Cables Standards: IEC60502, GB/T12706-2008 Application: It is suitable to be installed in duct, tray or direct burial, with rated voltage of U0/U (0.6/1KV) for transmitting electricity. Service Conditions: 1. Regular nominal cross-sectional areas: 1.5 mm2, 2.5 mm2, 4 mm2, 6 mm2, 10 mm2, 16 mm2, 25 mm2, 35 mm2, 50 mm2, 70 mm2, 95 mm2, 120 mm2, 150 mm2, 185 mm2, 240 mm2, 300 mm2, 400 mm2, 500 mm2, 630 mm2, 800 mm2, 1000 mm2, 1200 mm2 2. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will not be affected by eciencies in the installation.
1, Use: Aluminum wire and ACSRs structures are simple. They are easy to set up and maintenance. The cost is low in building the lines. The transmission capacity is large. They are also convenient to cross special geographical conditions, such as rivers, valleys and so on. So the products are applied for various voltage levels of overhead transmission and distribution lines. 2, Model Model Name cross sectional area LJ aluminum wire 16-500 LGJ ACSR 10-240 GB/T1179-1999 "Round wire concentric lay, stranded conductors" standard is equivalent to IEC61089-1991 standard. According to user needs. Our company can produce the aluminum wire and ACSR on the basis of ASTM, DIN, BS and other standards. Note: the products model and code in GB1179-83 of the new and old standard still has a large number of users and market, it can be used as non-standard£¨or users special needs£© when ordering the products. 3, material standards: Aluminum wire and ASCR with a hard steel core execute GB/T17048 (identical with IEC60889 standard). ACSR with galvanized steel execute IEC60888 standards. According to users needs, we can produce the production on the basis of the user's material standards and requirements. 4, product performance: the electrical properties of aluminum wire and ACSR should be showed as the resistance at 20 ¡æ. Hard aluminum wire's resistance is not greater than the international standard value 0.028264¦¸.mm2 / m. ACSR has three intensity levels: general intensity level ACSR, high strength ACSR and extra high strength grade level ACSR. 5, product maintenance: the product should avoid squeezing and bumps during handling and transportation. Cables should not be laid flat during the transportation and storage. Product should take moisture measures during storage.
1. Fibre optic patch cord LC/UPC-SC/UPC Singlemode Duplex 2. Various kinds of connectors available, LC, SC.ST, FC, MTRJ, E-2000, MTP 3.Optional Outer Jacket, PVC,LSOH 4.APC Polish Available 5.Custom length, metres, feet accepted. depends on the lengh and quantity.