Compressor wash fluid for diesel/gas turbine engines.
TI UNITS Reciprocating Water Chillers are available in two types of air cooled and water cooled in capacity range of 5 to 240 tons of refrigeration and compressor configurations of one to four. Evaporators and condensers are high efficiency shell and tube heat exchangers designed based on TEMA (Tubular Exchanger Manufacturers Association) standards. Safety controls installed on all units include high and low pressure cut-outs, compressor oil pressure safety cut-out, water anti freeze thermostat, water flow switch and evaporator entering water thermostat. Whatever mentioned above, are all chosen from the most recognized controls manufacturers in the air conditioning industry. Compressors are by DWM COPELAND and BITZER which happens to be one of the best and the most reliable brands. Raw materials such as copper tubes, fittings and valves are supplied by well respected manufactures. Electrical safety measures such as three phase controller and circuit breakers are available on all units. A fault detection system for the whole unit is available upon request. Microprocessor based PLC controller is also available as needed.
TI UNIT screw chillers are manufactured in two types of air cooled and water cooled in capacities from 50 to 560 T.R. in one to four circuited configurations. Evaporators and condenser Chillers with plate type heat exchangers are available upon request. For further related technical information, please send your inquiries to TI UNIT mfg. group. TI UNIT screw chillers can be designed to operate with R-22 and R-134a refrigerants. Bitzer screw compressors suitable for use with R-134a refrigerant are available in two versions (m.vr.1 & m.vr.2) which can be used in the chillers as required. Safety controls installed on all units include high and low pressure cut-outs, compressor oil level control safety cut-out, water anti freeze thermostat, water flow switch and evaporator entering water thermostat and compressor operation time logger. The above mentioned are all chosen from the most recognized controls manufactures in the air conditioning industry. Compressors are by Bitzer which happens to be one of the best and most reliable brands. Raw materials such as copper tubes, fittings and valves are supplied by well-respected manufactures. Electrical safety measures such as three phase controller and circuit breakers, are available on all units. A fault detection system for the whole unit is available upon request. Microprocessor based PLC controller is also available as needed. TI UNIT screw chillers are also available upon request for industrial applications in both Air Cooled and Water Cooled types; Suitable accessories make the chillers operable in all seasons according to the application requirements without any problems.
Supplier of new and used construction equipments and road machinery, material handling equipments, port equipments, access platforms, manlifts, generators, towerlights, compressors, cranes, stationary and mobile crushers, spare parts of heavy machinery, spare ac parts of commercial vehicles and machinery, spare parts of crusher and batching plants, engine parts, rock breaker chisles and pistons.Export documentation , shipping and clearing assistance
Beef and goat meat from Somalia (chilled/frozen) Shipping to all countries of the world Refrigerated meat can be shipped via air within 36-48 hours (the minimum order quantity in cargo is 10 tons)
Base Oil & Lubricants) Group I - SN 150 / SN 500: Group I base oils are classified as less than 90 percent saturates, greater than 0.03 percent sulfur and with a viscosity-index range of 80 to 120. The temperature range for these oils is from 32 to 150 degrees F. Group I base oils are solvent-refined, which is a simpler refining process. This is why they are the cheapest base oils on the market. Group II base oils are defined as being more than 90 percent saturates, less than 0.03 percent sulfur and with a viscosity index of 80 to 120. They are often manufactured by hydrocracking, which is a more complex process than what is used for Group I base oils. Since all the hydrocarbon molecules of these oils are saturated, Group II base oils have better antioxidation properties. They also have a clearer color and cost more in comparison to Group I base oils. Still, Group II base oils are becoming very common on the market today and are priced very close to Group I oils. Group III base oils are greater than 90 percent saturates, less than 0.03 percent sulfur and have a viscosity index above 120. These oils are refined even more than Group II base oils and generally are severely hydrocracked (higher pressure and heat). This longer process is designed to achieve a purer base oil. Although made from crude oil, Group III base oils are sometimes described as synthesized hydrocarbons. Like Group II base oils, these oils are also becoming more prevalent. Group IV base oils are polyalphaolefins (PAOs). These synthetic base oils are made through a process called synthesizing. They have a much broader temperature range and are great for use in extreme cold conditions and high heat applications. Group V base oils are classified as all other base oils, including silicone, phosphate ester, polyalkylene glycol (PAG), polyolester, biolubes, etc. These base oils are at times mixed with other base stocks to enhance the oil’s properties. An example would be a PAO-based compressor oil that is mixed with a polyolester. Esters are common Group V base oils used in different lubricant formulations to improve the properties of the existing base oil. Ester oils can take more abuse at higher temperatures and will provide superior detergency compared to a PAO synthetic base oil, which in turn increases the hours of use.
TI UNIT compact roof top chiller units are manufactured in type of air cooled in capacities of 5 to 360T.R. in one to four circuited configurations. In all TI UNIT compact roof-top chiller units the frames and body are from galvanized steel & stainless steel (316l) (option) the chassis made steel channel in appropriate thicknesses and all of units are completely painted in the proper thickness. Evaporators are high efficiency shell and tube heat exchangers, designed based on TEMA. Condenser of compact rooftop chiller unit made of plated coil, designed based on TEMA. Chillers with plate type heat exchangers are available upon request. TI UNIT compact roof top chillers can be designed to operate with R-22, R-407C and R-134a refrigerants. Safety controls installed on all units include high, oil and low pressure cut-outs, compressor safety cut-out, water anti freeze thermostat, water flow switch and evaporator entering water thermostat and compressor operation time logger. The above mentioned are all chosen from the most recognized controls manufactures in the air conditioning industry. Automatic condensing temperature control: A controller, factory installed on each unit automatically stages the condenser fans allowing the unit to start. With this controller the condenser fans start stage by stage. Raw materials such as copper tubes, fittings and valves are supplied by well-respected manufacturers. Electrical safety measures such as three phase controller and circuit breakers are, available on all units. A fault detection system for the whole unit is available upon request. Microprocessor based PLC controller is also available as needed. Suitable accessories make the chillers operable in all seasons according to the application requirements without any problems.
In all TI UNIT air handling units the frames are from aluminum profiles while the chassis and body panels are made from galvanized steel sheets in appropriate thicknesses. All units are completely painted in the proper thickness. Blower(S): Double width-double inlet centrifugal fans with forward curved blades are normally used for low pressure drop requirements as opposed to fans with backward curved blades which are for high pressure drop applications. Fans and housings are made of galvanized steel each set off a plus other related components such as shafts are statically and dynamically balanced, shafts are selected from proper material and size. Other power transmission components such as pulleys and belts are also suit ably chosen depending on the required fan speed and electric motor power. Fan(s) and the corresponding electric motor(s) are installed on an independent chassis which is itself installed on the main chassis using vibration dampers in order to eliminate transfer of vibrations to the structure. To further reduce the effects of vibrations, fan outlet (s) are also connected to the structure via flexible material such as canvous. All 380V/3/50Hz electric motors are selected with insulation class of (f) and ingress protection of (IP- 54). Electric motors with ingress protection of (IP- 55) are also available upon request. Coil (S): Cooling and heating coils or either one of the two depending on the Requirement May be installed. Cooling coils are available in two, types of chilled water and direct expansion (D.X.) as per clients requirements. The chilled water coils are constructed of 5/8 O.D copper tubes plate finned (8, 10, 12 or 14 FPI) in aluminum or copper upon request. The D.X. Coils are constructed of 3/8 OD copper tubes also plate finned (10, 12 or 14 FPI) in aluminum or copper as required. The chilled water for cooling coils in to be supplied by a water chiller and in the D.X. coils cooling is provided through the use of refrigerant such as R-22, R-407c or R-134a. Chilled water coils may be requested in 4 or 6 rows and as to the D.X. coils, they are available in 4 or 6 row configurations. Heating coils are available in two types of hot water and steam. The hot water coil similar to chilled water coil is offered in 1 or 2 row configurations. Steam heating coils are constructed of 1/2 seamless steel pipe spiral finned in aluminum or copper. Coils in 1 & 2 -row configurations are available upon request. Mixing box: Fresh and return air streams are mixed in the mixing box .An independent air damper is included for each air stream. Air Dampers are manufactured from aluminum in opposed blade configuration and are air sealed through the use of rubber strip gasket. Damper actuators ma y be easily installed when required. Washable aluminum filter modules 2 inches in thickness are arranged in (V) type configuration inside these boxes. Housing for
Engine oils , grease, compressor oil, cutting oil.hydraulic oils , transmission oils.