FUJI developed the first infrared gas analyzer in Japan to use mass-flow sensors. Since then, we have supplied customers with various types of gas analyzers to support environmental preservation and control efforts. These efforts include measurements of atmospheric pollution and detection of low density of SOx and NOx, generated by incinerating facilities and boilers. FUJI's gas analyzers are widely used to monitor the atmosphere to help maintain a cleaner natural environment.
Diesel vehicle exhaust gas analyzer (can also be used in gasoline vehicle), belong to customized products, non standard. Increase the reverse blowing system and filtering, purifying device. Can be used for the detection and analysis of diesel oil as fuel of vehicle exhaust emissions group points. ã??Main technical parametersã?? exhaust gas analyzer measuring range COï¼?0ï½?10.0 10-2(%) CO2ï¼?0ï½?20.0 10-2(%) HCï¼?0ï½?9999 10-6(ppm) O2ï¼?0ï½?25.0 10-2(%) NOï¼?0ï½?5000 10-6(ppm) oil temperatureï¼?18ï½?150 speedï¼?100ï½?20000rpm resolving power COï¼?0.01% CO2ï¼?0.1% HCï¼?1ppmO2ï¼?0.01% NOï¼?1ppm oil temperatureï¼?0.1 speedï¼?1rpm Repetitive error â?¤±2% Zero drift COï¼?±0.06 10-2(%)/4h CO2ï¼?±0.5 10-2(%)/4h HCï¼?±30 10-6(ppm)/4h O2ï¼?±0.5 10-2(%)/4h NOï¼?±30 10-6(ppm)/4h Distance drift No more than shown value error allowed (4 hours) Indication error COï¼?±5%ï¼?absolute errorï¼?±0.03 10-2 ï¼? CO2ï¼?±5%ï¼?absolute errorï¼?±0.5 10-2ï¼? HCï¼?±5%ï¼?absolute errorï¼?±10 10-6 ï¼?±5%ï¼?absolute errorï¼?4001ï½?10000ppmï¼? O2ï¼?±5%ï¼?absolute errorï¼?±0.1 10-2ï¼? NOï¼?±4%ï¼?absolute errorï¼?±25 10-6ï¼? environment condition oil temperatureï¼?±2ï¼?relative errorï¼? speedï¼?±1.0%ï¼?relative errorï¼? temperatureï¼?0ï½?40 humidityï¼?â?¤80% atmospheric pressureï¼?60ï½?105KPa Power Supplyï¼?AC 220V±10%ï¼?50Hz±1Hz(Automobile power supply inverter) Preheating time 10min Weight Measurement unitï¼?10Kg vice machineï¼?3Kg Volume Measurement unitï¼?610 * 500 * 330mm Auxiliary machine:500 * 350 * 330mm Sampling method Exhaust gas: direct sampling, sampling tube length 5m, sampling probe length 900mm; Temperature: the temperature measuring head into the engine lubrication oil scale hole, insert the oil rod and the length of the same length, rubber stopper blocked, to prevent oil jet and wire length: 5m; Speed: the tachometer speed clip in high pressure flexible gasoline engine, can determine the speed of a gasoline engine. Display mode LCD large screen liquid crystal display major function 1)Meet GB18285-2005 national standard requirements, measurement of motor vehicle gasoline engine emissions of HC, CO, CO2, O2 and NO concentrations,Of HC, Co, CO2, the advanced NDIR regardless of light and infrared analysis technology (imported from movement detection equipment to meet the requirements of national standard OIMLR99 0 level precision, high precision, strong stability) and of O2 and no by the new electrochemical analysis technology for detection. 2)With idle speed, double idle test function; 3)Auto calculation shows that the excess air coefficient isï¼? 4)Equipped with RS-232C digital serial communication interface, convenient networkingï¼? 5)Matching speed and temperature measurement functionï¼?
In order to guarantee gas dispenser quality, our company has established an experiment center for testing and detection of overall performance of gas dispensers. This center can comprehensively simulate actual operation of gas stations and completely detect over ten functions like gas tightness, pressure protection, quantifiable gas filling, gas filling in order, segmental measurement correction for gas filling, break-away protection, solenoid valve reliability, mass flow meter accuracy, repeatability, and zero correction. Place of origin :sichuan, china (mainland) Brand name :hantu Model number :jqj-c-ii Condition: new After-sales service provided: engineers available to service machinery overseas
Orotech¡¯s product is very durable in h/w, moreover outstanding accuracy and stability in the measurement, And also nox measurement upgradable and temporary pause to measurement(hold function) too. Size : 0.40 x0.53 x 0.35 Weight : 12.0 kg/box Dimensions : 0.074 cbm/box
Kq500 fixed gas detector is a kind of wall-mounted type detector that can be used continuously in operation environment to detect the concentration of combustion gas, oxygen, and toxic gas. The detector detects gas concentration in natural diffusion way. Kq500 intelligent gas detector transforms the gas density in the operating site into standard electric current signal(4-20ma). Main features: L it can detect more kinds of gas. High precision L fixed explosion-proof shell; it¡¯s safe and reliable L standard 4-20ma electric current output, compatible with existing alarm control unit or dsc (distributed control system). L imported sensor, high sensitivity, rapid response, stable and reliable Operation is simple; easy installation and maintenance Box
Kq500d intelligent gas detector is a kind of wall-mounted type detector that can be used continuously in operation environment to detect the concentration of combustion gas, oxygen, and toxic gas. The detector detects gas concentration in natural diffusion way. Kq500d intelligent gas detector transforms the gas density in the operating site into standard electric current signal(4-20ma). With led display, detector's sensor can be changed and reused as soon as it is connected to electricity. Main features: standard 4-20ma electric current output, compatible with existing alarm control unit or dsc (distributed control system). led site display that is suitable for factory (optional lcd display) L standard three buttons: so an individual can operate the detector in site. L automatic identify and display the sensor failures, and output the corresponded current signal at the same time. L the key operation needs to input password to prevent wrong operation. L simple calibration function; reducing measuring error L two levels' light alarm, relay output (connected with audible and visual alarm outside or start the exhaust system) Box
Available in both portable and fix type for all type gases, eg oxygen/lpg/organic vapour/explosive/toxic gases. -gives alarm -indicate measured gas value in digital display - multichannel gas detector with compact datalogger. Product dependent
Gw series wireless transcription intelligent gas meter is high-tech integrative product. This series meter uses advanced wireless transmission technology. Through microelectronic control circuits, it converts the pulse signals of traditional mechanical meter into electrical signals. Then the metering data is transmitted to background platform through gprs network automatically, or it can be collected by a hand-held wireless unit from outside of the houses and after that downloaded to a computer through USB port.
GW series wireless transcription intelligent gas meter is high-tech integrative product. This series meter uses advanced wireless transmission technology. Through microelectronic control circuits, it converts the pulse signals of traditional mechanical meter into electrical signals. Then the metering data is transmitted to background platform through GPRS network automatically, or it can be collected by a hand-held wireless unit from outside of the houses and after that downloaded to a computer through USB port.
Introduction: Equipped with our companys code controller, base meters are bought abroad to realize the prepaid and control functions, thus to achieve the automatic control of different functions of this new type of gas meter. Range of application: This product can be applied to the measurement of gas, natural gas, liquefied petroleum gas and other non-corrosive gases in the city. Main features: Automatic prepaid function: charging before using of it, water meter residual capacity= the original gas + newly purchased gas auto-control function: switching the gas path automatically according to the payments and gas situation. Real time computation function: measuring on the real time and display the stock value, closing gas source automatically when the purchased gas is used up. Power-down memory function: solid state recorder is internally installed and the data will be permanently preserved. Status display function: displaying the amount of newly charged gas, the remaining stock and cumulative use, as well as low-voltage state etc. Prompting function: warning when the remaining gas is used to the set value or other functions are out of work. Overdrawing function: able to set a certain overdraft gas according to the user needs Automatic alarm function: when the voltage is lower than certain point, alarm system will be operated and the battery must be replaced within 72 hours, otherwise, it will automatically shut down the gas resources. Anti-gas-larceny function: shut down the gas supply automatically when there are theft of gas or illegal operations Technical parameter: Base meter operation criteria¦gb/t6869 q/ofd.001-2007 jjg577-2005 Current working voltage¦3.00v Cuiescent current¦=8 years Life span of valve¦switching frequency more than 5000 times Accuracy degree¦level b Four anti-function¦anti-attack, waterproof, anti-smoke, anti-knocking
Gas analyser Analysers for stack and ambient air pollution monitoring Also used for petrol and diesel vehicles
Hydrogen Purity Analyzer: Vasthi Portable Hydrogen Purity Gas Analyzers Model VHP- 200 is a light weight, easy to handle, battery-powered analyzer, used to verify measurements and for spot-checking when other methods provide questionable results.
Hydrogen Purity Analyzer: Vasthi Portable Hydrogen Purity Gas Analyzers Model VHP- 200 is a light weight, easy to handle, battery-powered analyzer, used to verify measurements and for spot-checking when other methods provide questionable results.
Vasthis handheld Flue gas analyzer,Model-VE5400 offers the efficiency of complete combustion optimisation all the way to comprehensive measurement and customer data management.Our Portable flue gas analyzers cover the entire measurement and documentation requirement in process and flue gas testing with instant reading. Vasthiâ??s VEA800 series is an ideal analyzer that measures 5 gases with 4 sensors. User friendly gases selection is implemented in this analyzer. This Portable Flue Gas Analyzer consists unique features.It has in-built crystal-clear touch display which enables user to view concentration values of flue gases and Bluetooth/Wi-Fi connectivity facilities.Using these facilities,Users can download the stored data as well as print it with any printer using Bluetooth / Wi-Fi User can compare daily data with charts & graphs to optimize and increase the combustion efficiency. Measuring Gases SO2,NO,CO2,NO2,Flue Gas Temperature & Temperature combustion air VASTHI will give the gases as per customer required..
Product Introduction Chromatographic analysis technology is a kind of separation and analysis technology of multi-component mixture. It mainly makes use of the difference of boiling point polarity and absorption add coefficient of each component in the sample in the chromatographic column so that each component can be separated in the chromatographic column and detect the separated components by detection apparatus so as to conduct qualitative and quantitative analysis of multi-component mixture. Because this method has a high separation efficiency fast analysis less sample consumption etc therefore has been widely used in petrochemical biochemical medicine and health food of the health and quarantine inspection of environmental protection industry in the medical clinical departments by gas chromatography in the field of solve the industrial production of intermediates and pollution detection of industrial products quality inspection scientific research production control and other issues. Chromatographic instrumentIt is a kind of high cost performance multi-function economical and practical precision instrument which adopts three-column and three-gas circuit operating system. The basic type is equipped with hydrogen flame ionization detection (FID) and thermal conductivity detection deviceï¼?TCDï¼?. Chromatographic instrumentUsing microcomputer and integrated circuit control English and Chinese interface high degree of self-motion and good reliability operating parameters keyboard setting instrument with power failure protection file storage and call function instrumentLarge screen liquid crystal displayï¼?The detection apparatus and its control assembly unit adopt plug and play control modesimplicity of operator for the instrument to conduct constant temperature and program temperature rise operation column room is equipped with flexible rear door self-motiontemperature control system the column box has excellent performance high precision temperature control quick rise and drop speed and flexible air temperature operation process Reliable easy to expand suitable for a variety of detection and sample combinations. The detector adopts the unitized combination design which is easy to install and maintain. The chromatograph can be configured with a variety of detectors (TCD FID ECD FPD and NPD). According to the user's analysis needs the chromatograph can be configured with up to four detectors at the same time. The chromatograph's injection system can be equipped with a variety of injection devices such as filling column head injection glass lining rapid injection and capillary column divided/undivided injection with diaphragm cleaning function.
Application: TKQC type SF6 gas recovery device is an integrated recovery device. The device is composed of a recovery system a vacuum pumping system a cleaning system a storage system and a condensing system. Features: Adopt advanced principles and technology advanced design complete function reasonable structure simple operation. Two-stage rotary vane vacuum pump the vacuum speed is fast and equiped with anti oil return device. Automatically confirm and adjust the three phase power supply for electrical system. Using the newest patented technology SF6 special instrument and valves more reliable than similar products. The device adopts air cooling movable type and can be used without external water source.
Chromatographic analysis technology is a kind of separation and analysis technology of multi-component mixture. It mainly makes use of the difference of boiling point polarity and absorption add coefficient of each component in the sample in the chromatographic column so that each component can be separated in the chromatographic column and detect the separated components by detection apparatus so as to conduct qualitative and quantitative analysis of multi-component mixture. Because this method has a high separation efficiency fast analysis less sample consumption etc therefore has been widely used in petrochemical biochemical medicine and health food of the health and quarantine inspection of environmental protection industry in the medical clinical departments by gas chromatography in the field of solve the industrial production of intermediates and pollution detection of industrial products quality inspection scientific research production control and other issues. Chromatographic instrumentIt is a kind of high cost performance multi-function economical and practical precision instrument which adopts three-column and three-gas circuit operating system. The basic type is equipped with hydrogen flame ionization detection (FID) and thermal conductivity detection device TCD. Chromatographic instrument using microcomputer and integrated circuit control English and Chinese interface high degree of self-motion and good reliability operating parameters keyboard setting instrument with power failure protection file storage and call function instrument large screen liquid crystal display. The detection apparatus and its control assembly unit adopt plug and play control model simplicity of operator for the instrument to conduct constant temperature and program temperature rise operation column room is equipped with flexible rear door self-motion temperature control system the column box has excellent performance high precision temperature control quick rise and drop speed and flexible air temperature operation process Reliable easy to expand suitable for a variety of detection and sample combinations. The detector adopts the unitized combination design which is easy to install and maintain. The chromatography can be configured with a variety of detectors (TCD FID ECD FPD and NPD). According to the user's analysis needs the chromatograph can be configured with up to four detectors at the same time. The chromatograph's injection system can be equipped with a variety of injection devices such as filling column head injection glass lining rapid injection and capillary column divided/undivided injection with diaphragm cleaning function. Product nickname hydrogen generator full-automatic hydrogen generator self-motionHydrogen generator chromatographic instrument
Its simple automatic operation, continuous measurement & digital display of purity concentration makes it a valuable aid for on-site instant analysis & follow up action. Its data logging & computer interface features can be used for further detailed analysis in the laboratory.The HNL Portable Model GA - 154 with digital read out and alarms is a direct reading compact Portable Gas Purity Analyzer, designed to serve the demanding field requirements of various gases Producing and using Industry. It is designed to replace the cumbersome and time consuming Or set apparatus and provide quick and accurate reading of gas Purity. It offers the user a distinct advantage in terms of economy, dependability maintenance and ease of operation. The instrument incorporate TCD / INFRARED as a transducer. It has adjustable visual and audible alarms with Automatic Zero Calibration Feature
Welcome to Relon. Rakshak Gas Guard Mini is a small device that can be installed easily by the customers themselves.
Portable Combustible Gas Detector TC-BO3-3 Combustible Gas Detector Detection of gas: Combustible gases, organic solvents, etc. TC-BO3-3 Combustible Gas Detector Technical Parameters * Detection of gas: Combustible gases, organic solvents, etc. * Detection Mode: Diffused * Detection principle: Semiconductor type * Measuring range: 0-20% LEL (combustible gases) * Accuracy: full scale ± 5% LEL * Response time: T90