Dot/tc approved Tped pi approved 25 pcs in one carton
Model Jay-5 Flow rate0-5l/min Purity93,3% Outlet pressure (mpa)0.04-0.07 Sound level 50db PowerAc220v,10%, 50/60,1hz; ac110v,10%, 50/60,1hz Power consumption 480w Lcd displaySwitch times, operating temperature, operating time/timing, accumulating time AlarmPower failure alarm, high&low pressure alarm Net weight26kgs Size (mm)365¡á375¡á600mm Optional: *nebulizer function *low purity alarm: when oxygen purity is above 82%, it will give green light; when the purity is blow 82%( 82% not included), it will give red light *maintenance alarm: alarm for maintenance after 3000 hours operation *alarm for high temperature inside systems above 50 degree. *pulse oximeter: fingertip pulse oximeter is available for monitoring patient oxygen saturation on site. *dual flows Carton:43.5x43.5x64cm
PB companion 31A liquid oxygen base reservoir.
Liquid oxygen resevoirs.
Puritan bennett companion 41a.
Puritan bennett companio 1000. Shipping details vary by location, and by order quantity and variety.
Puritan bennett helios 300. Shipping details vary by location, order quantity, and customer requirements.
Input pressure:15mpa Output pressyre:0.2-0.3 mpa Safety device:0.35+0.05 mpa Flow:0-15LPM Connection thread:G5/8,CGA540....or you decide Outlet thread:G5/8....or you decide, and you can contact ethanvuv(skype) (medical oxygen regulators, medical oxygen pressure regulators, oxygen inhalers/inhalators, oxygen absorbers, oxygen reducers, oxygen flowmeters,oxygen flow meters with regulators, oxygen therapy regulator, breathing apparatus, medical devices) Oxygen Therapy regulators are at work in hospital, clinics, home care worldwide emergency units & etc. For true reading flow meter must always be vertical *Fully chromed *Easy to read dual scale gauge with screw-on polycarbonate lens for durability *Precision engineered pressure compensated design flow meter for precise flow *Flow meter with easy to read tube and virtually unbreakable transparent polycarbonate outer cover for strength and 3600 visibility *Sintered bronze inlet filter. *This design is simple and accurate The flow meter with humidifier is used in reducing gas pressure and adjusting the gas volume, which rescue patient and treat as oxygen therapy by hospital. Also may make using of other gas reduced pressure and the control flow. Product main feature: The product has artistic outlook, and flow control comfortable and stable. The reductor is adjustable; The structure is unique, and the performance is reliable. The stainless steel floater and the orange substrate flow meter have a especially visual effect; The international standard connect way, is suitable for all kinds of gas bottle installation. CTNS.
Voltage: 100-240V 50/60Hz Flow Rate: 0.5 to 10 lpm Oxygen Concentration: 93%¡À2% 0~7L 90%¡À2% 8L 80%¡À2% 10L Oxygen Outlet Pressure: 8.5 psig ¡À 5 psi Power Consumption: 500 W (average) Sound Level: 50 dBA Start-up test; Power failure alarm Accumulative time display LCD display Circuit breaker. Dimensions: 356 (W)* 305 (D)* 610(H) mm Weight: 20 kg. Packed in cartons,9sets/pallet.
These ultimate machines allow to produce 93% purity of Oxygen in only 3 minutes 24/7 without a pause to meet customers' demand. All the self-contained oil-free air compressor by compact modular designed models require no regular maintenance with more efficient performance.
Medical ozone generator mog-080 Controlled by high clear colored touching lcd screen and produce highly concentrated medical ozone gas precisely. Make use of medical oxygen to produce ozone gas with high-purity in the medical treatment rank. Controlled by the programmed microcomputer, instructed and operated by high accuracy colored touching lcd screen [made in japan]. German ultraviolet photometer and control device, to measure and adjust ozone concentration in real time. Monitor the entire treatment process under the safety control system. 111
1. Designed specifically to meet the ERC's 2006 tidal volume guidelines. 2. Textured bag provides positive grip, even when wet. 3. 360 degrees swivel for ease of use with facemask or endotracheal tube. 4. Child and infant bags complete with 40cm H2O safety pressure release valve, minimizes the risk of over inflating the lungs. 5. Excellent recoil recovery following bag compression. 6. Single use product prevents cross infection. 7. Clear non-rebreath valve 8. Transparent material allows internal visibility 9. Latex free, toxic free
1. Designed specifically to meet the ERC's 2006 tidal volume guidelines. 2. Textured bag provides positive grip, even when wet. 3. 360 degrees swivel for ease of use with facemask or endotracheal tube. 4. Child and infant bags complete with 40cm H2O safety pressure release valve, minimizes the risk of over inflating the lungs. 5. Excellent recoil recovery following bag compression. 6. Single use product prevents cross infection. 7. Made out of silicone for reusable with autoclaving temperature over 134 degrees Celsius. 8. Clear non-rebreath valve 9. Transparent material allows internal visibility 10. Latex free, toxic free 11. No MOQ 12. OEM available
We can offer gas vaporisers for all your cryogenic gases including LNG.
1. Oxyfree label (oxyfreesticker) is self-adhesive and can stick in the inner Wall of food package. 2. Oxyfree roller type of sachets (in strip) can be applied with pouch Dispenser machines. Standard lot size
Feature It is a ventilation device for infant with novel structure and good performance, and chooses opening ventilation mode with high frequency and little tidle volume, so the airway pressure is low.If you want to know more. A. The tidal air can letout with constant pressure, constant current or accurately adjustable flow. B. Opening ventilation, opening intubation makes it not need casing bag, little resistance as expiration is suited for the ventilation management of infant. C. Evident effectiveness of treating ards can be shown with inserting small tube and jetting oxygen through nasal vestibule, which is secure and doesn't cause pressure wound easily. D. Peep and humidifier volume can be adjusted accurately. E. Alarm system with sound and light when no oxygen, poor of electric quantity or low airway positive pressure. F. Heated humidifier can be used for good effectiveness of humidifying. G. Accumulator jar, it can be used while being charged and can last for more than four hours. Specifications Frequency10+150 breaths/min I/e ratio1:1, 1:1.5+ 1:3 and inverse ratio Pressure atomizer rate>=6ml/h Process ventilationt=10min, Proi:f(150):f(35)=7:3 Proii:f(35):f(150)=7:3 Storage battery4ah, automatic charge when 12v Sigh:3breaths/min Alarm:alarm when battery voltage is lower than 11v, alarm lasts 6 seconds if no oxygen, alarm with audible signals and flashing light when the airway pressure is over 0.8kpa Cpap0+0.5kpa Peep0+0.20kpa Oxygen concentration adjustable:21%-90% Jetting volume rangeo+600ml/time Ventilation mode:hfjv(high frequency jet ventilation);cpap(continuous positive airway pressure);hfjv+peep(positive end-expiratory pressure), hfjv+sigh(sigh), process ventilation i and process ventilation ii. Standard packaging.
Feature It is widely used for clinical salvaging and revival also is a dedicated device used for respiration salvaging on emergency ambulance. A. An opening system is designed to avoid leakage of airway, when ventilating, the intubations may have no casing bag. Little tube may be used for ventilation when resistance of expiration is small, so that mucose won't be hurt easily. B. Airway is open during ventilation, suction and ventilation can be done synchronously, so good effectiveness of oxygen combination can be shown without inspiration and expiration synchronizing. C. Lower airway pressure is good to increase blood discharge and decrease encephal pressure. D. Suction device, its driving negative pressure is adjustable. E. Accumulator jar, it can be used continuously for not less than four hours after being charged. F. The system disposes completely with laryngoscope, inlet intubation, catheter of tracheotomy, nasal prongs tube, and air tube etc. Specifications Frequency: 10 150 breaths/min I/e ratio1:1, 1:1.51:3 and inverse ratio Sigh:6breaths/min, Cpapf1.5kpaff Suction negative pressure:-0.050mpa Driving pressure 00.15mpa Constant volume ventilation: t=10min, i/e=1:1.5 Adults:f(100):f(20)=7:3, tidal volume=550ml/time, driving pressure=0.06mpa Children:f(100):f(20)=7:3, tidal volume=350ml/time, driving pressure=0.04mpa Storage battery:4ah, automatic charge when 12v Most jetting volume:f1400ml/time Oxygen concentration adjustable:40%-90% Alarm: alarm when battery pressure is lower than 11v; alarm when the oxygen pressure is lower than 0.01mpa; alarm with sound and light when no gas Ventilation mode:hfjv(high frequency jet ventilation);cpap(continuous positive airway pressure), hfjv+sigh;constant volume ventilation. Standard packing.
Feature A. The device adopts impulse jet oxygen feeding technique with great flow rate of oxygen feeding in a shot while, when feeding oxygen, it adopts change mode major in reflux and many kinds of gas flow mechanism such as convection, laminar flow, sheet flow and so on concurrently, which is good to increase partial pressure of oxygen rapidly, at the same time fluctuation of thorax caused by increasing oxygen flow into airway is good to let out co2. B. Jet oxygen feeding is supported by pressure when inspiration and secure certain peep effect when feeding oxygen, so as to reach good effectiveness of oxygen feeding. C. Accumulator jar, it can be used while being charged and can last for four hours after having been charged. D. Alarm system with sound and light when lack of electric quantity or airway pressure. E. 300cg chooses digital display of import pressure sensor. F. 300cg has three kinds of airway limited pressure alarm for adult, child and infant. G. The device disposes pressure humidifier which has good humidigying effectiveness. Specifications Power supply:ac220v+22v 50hz+1hz I/e ratio1:1, 1:1.5+ 1:3 and 3:1 Driving pressure 0+0.15mpa Sigh:6breaths/min, i/e=1:4 Pressure regulator limit:0.30mpa Cpapnot less than 1kpa Oxygen concentration adjustable:40%-90% Process ventilationt=10min, infinite recursion Proi:f(150):f(35)=7:3 Proii:f(35):f(150)=7:3 Alarm:alarm with light and sound for no gas or no power or airway pressure is over Inner battery:4ah 12v Ventilation mode:hfjv(high frequency jet ventilation);cpap(continuous positive airway pressure), hfjv+sigh(sigh); process ventilation i and process ventilation ii, manual control mode. Standard packing
A. When the ventilation technique with open high frequency and low humidify volume is adopted, the airway pressure is low with little effect of oxygen compound is good and the oxygen partial pressure can be increased rapidly. While the one with regular frequency and great humidify volume is adopted, CO2 can be ejected easily. B. Convenient connecting, it can be connected through the nasal and endotracheal tube. C. The ventilation mode with high frequency and low humidify volume will not easily produce pressure hurt. D. The effect of oxygen dispersion is so good that the tested beastie can stand for a long time. E. Adjustable oxygen concentration, the ventilation mode with continuous oxygen stream and good humidifying effect can ensure beastie to respire independently. F. Be fit for manual ventilation test for monkey, rabbit, dog etc. G. Configured with multiform ventilation conduit for beastles or connected with gas source, in addition. Specifications·ª Frequency:8f+150 breaths/min I/E ratio·ª1:1f+1:3 and inverse ratio Driving Pressure ·ª0f+0.08MPa Gas source: High-pressure oxygen source or air compredsor. The input pressure is not more than 0.16MPa High-pressure gas source:0.16MPa Output Limit of reductor: not less than 0.16MPa Ventilation Mode:HFJV(High Frequency Jet Ventilation);CPAP(Continuous positive airway pressure),Manual Control Mode.
Medical gas terminal outlet Medikar q-click terminal units newly designed arised from the difficulties of repairing and replacing medical gas terminal units in working hospital areas, especially in intensive care units, sbcu, operation theatres, and emergency departments where highly crowded and continuous patient and staff movement exist. It is very difficult to shut off gas flow and perform maintenance on the usual terminal units. Medikar q-click terminal units allow the maintenance, repair and replacement of the terminal units so easy that it takes only a few seconds. Also medikar q-click terminal units allow changing 2nd fix and convert the unit from bs standard to din standard or to en standard and vice versa. Medikar q-click terminal units consist of three main parts : a) base block (1st fix), b) cartridge and c) main body (2nd fix). A) Base block (1st fix) : made of forged brass and has a maintenance valve inside. It is tested under 10 bar pressure and contains gas specific pins and patented q-click mechanism. Inlet can be supplied by either brazed copper tube or brazed nist connector depending on the installation place. B) Cartridge : made of machined brass ; contains check valve which is the same for all gas types but differs according to the standard applied. C) Main body (2nd fix) : this is the part which makes our difference from other gas outlets. It consists of a locking mechanism, an indexing part for gas and standard differentiation and identification plate.