Application
Measuring the volume of cold potable water passing through the pipeline.
Features
Removable element for facilitating installation and maintenance, copper sealed register, long term clear reading, inter-exchangeable parts, magnetic transmission, low driving resistance. Reliable sensitive action, small pressure loss, long working life.
Application
Measuring the volume of cold potable water passing through the pipeline.
Features
Removable element for facilitating installation and maintenance, copper sealed register, long term clear reading, inter-exchangeable parts, magnetic transmission, low driving resistance. Reliable sensitive action, small pressure loss, long working life.
Low maintenance cost and easy installation
Long lasting performance: No maintenance and repair for 6 years
â?¢ Intelligent information can be output by providing advanced statistical data and
diagnostic programs
â?¢ Maximum tolerance of Class 1 meter: 1% in convection area ( Q2 â?¤ Q â?¤ Q4) 3 % in small
area (Q1 â?¤ Q â?¤ Q2)
[ SPECIFICATIONS ]
* Measuring caliber 25 mm ~ 1,200 mm
* Domestic Approval : 50 mm, 65 mm, 80 mm, 100 mm, 125 mm, 150 mm, 200 mm, 250 mm, 300 mm, 350 mm
* Composition : Detection unit: Electronic sensor / Conversion unit: input unit, operation unit, output unit, indicator
* Accuracy Full Scale: 0.2% (65 mm ~ 250 mm: 1st grade / 50 mm, 300 mm, 350 mm: 2nd grade)
* Max. Measureable Flow Rate : 10 m/s
* Display unit and contents : Accumulated flow (m3): 9 digit x 1 (forward, reverse, modification available) Instantaneous flow rate (m3 / h): 4 digits, date, time, alarm (battery life and empty pipe) and data logger
* Measurement function : Low flow cut off: 0 ~ 9 of maximum flow
* Measurement frequency : Battery Type : 1/5 Hz / AC Type : 6.25 Hz
* Max working pressure : 1.0 MPa ~ 1.6 MPa
* Input : 4 ~ 20 mA pressure gauge signal (Loop Powered Terminal): AC Type
* Output : 1 Instantaneous flow rate (4 to 20 mA) 1 - AC Type
2 accumulated flow (O.C Pulse) - Pulse Load 5 ~ 35 V DC / 50 mA
(Common for AC & Battery Type)
* Liner : Hard Rubber
* Electrode Hastelloy C
* Housing/Flange : Carbon Steel
* Communication and internal memory : RS 485 MODBUS: AC Type / Internal memory: Date, time, instantaneous flow rate, accumulated flow rate, and pressure Memory interval: 5 seconds ~ 24 hours (1 year storage upon 1 minute interval storage)
* Power Battery Type : 3.6 V DC (Life span 7 years) / AC Type : 110 ~ 220 V AC
* Temperature : Ambient temperature: 20 ~ 60 / Storage temperature: 30 ~ 70 (humidity up to 95%)
* Protection class : Detection unit (IP 68) / Converter (IP 65)
[ APPLICATIONS ]
Water industry / Wastewater treatment industry
For more details on quality Korean flowmeters, please feel free to visit http://www.hnl-global.com/flowmeter and contact us.
[ CHARACTERISTICS ]
Low maintenance cost and easy installation
Long lasting performance: No maintenance and repair for 6 years
Intelligent information can be output by providing advanced statistical data and diagnostic programs
Maximum tolerance of Class 1 meter: 1% in convection area ( Q2 â?¤ Q â?¤ Q4) 3 % in small area (Q1 â?¤ Q â?¤ Q2)
[ SPECIFICATIONS ]
* Measuring caliber 25 mm ~ 1,200 mm
* Domestic Approval : 50 mm, 65 mm, 80 mm, 100 mm, 125 mm, 150 mm, 200 mm, 250 mm, 300 mm, 350 mm
* Composition : Detection unit: Electronic sensor / Conversion unit: input unit, operation unit, output unit, indicator
* Accuracy Full Scale: 0.2% (65 mm ~ 250 mm: 1st grade / 50 mm, 300 mm, 350 mm: 2nd grade)
* Max. Measureable Flow Rate : 10 m/s
* Display unit and contents : Accumulated flow (m3): 9 digit x 1 (forward, reverse, modification available) Instantaneous flow rate (m3 / h): 4 digits, date, time, alarm (battery life and empty pipe) and data logger
* Measurement function : Low flow cut off: 0 ~ 9 of maximum flow
* Measurement frequency : Battery Type : 1/5 Hz / AC Type : 6.25 Hz
* Max working pressure : 1.0 MPa ~ 1.6 MPa
* Input : 4 ~ 20 mA pressure gauge signal (Loop Powered Terminal): AC Type
* Output : 1 Instantaneous flow rate (4 to 20 mA) 1 - AC Type
2 accumulated flow (O.C Pulse) - Pulse Load 5 ~ 35 V DC / 50 mA
(Common for AC & Battery Type)
* Liner : Hard Rubber
* Electrode Hastelloy C
* Housing/Flange : Carbon Steel
* Communication and internal memory : RS 485 MODBUS: AC Type / Internal memory: Date, time, instantaneous flow rate, accumulated flow rate, and pressure
Memory interval: 5 seconds ~ 24 hours (1 year storage upon 1 minute interval storage)
* Power Battery Type : 3.6 V DC (Life span 7 years) / AC Type : 110 ~ 220 V AC
* Temperature : Ambient temperature: 20 ~ 60 / Storage temperature: 30 ~ 70 (humidity up to 95%)
* Protection class : Detection unit (IP 68) / Converter (IP 65)
[ APPLICATIONS ]
Water industry / Wastewater treatment industry
Superior Hydraulic Design, Without Installation Requirements Of Straight Pipe
Wide Turndown Ratio, R is Up To 1000Suitable For Big Volume Flow And Tiny flow Measurement.
Suitable For Mass Flow And Tiny Flow Measurement
The Design Of Integrated Flow, Pressure, Wireless Reading Meets Monitoring Pipeline Requirement
IP68 Protection Class, Whole Meter Sealed Completely Ensures Long Term Underwater Working
Double D Size Batteries Can Continuously Work For 15 Years
Bi-directional Measuring Forward And Reverse Flow
Data Logger Function Can Save 10 Years Data Including Day, Month And Year
LCD Display Volume, Flow Rate, Flow Direction, Alarm, Leak Detection At The Same Time
Standard RS485 (Modbus-RTU), A Variety Of Options, NB-IOT, OCT, GPRS etc.
Electric Components According To ROHS, OSP Processed Circuit Board
Stainless Steel Body (SS304) is Integrated Stretching Patent Right Product
International Standard Flange Connection, Simple Installation
According To Sanitary Standard For Drinking Water
Superior Hydraulic Design, Without Installation Requirements Of Straight Pipe
Wide Turndown Ratio, R is Up To 1000Suitable For Big Volume Flow And Tiny flow Measurement.
Suitable For Mass Flow And Tiny Flow Measurement
The Design Of Integrated Flow, Pressure, Wireless Reading Meets Monitoring Pipeline Requirement
IP68 Protection Class, Whole Meter Sealed Completely Ensures Long Term Underwater Working
Double D Size Batteries Can Continuously Work For 15 Years
Bi-directional Measuring Forward And Reverse Flow
Data Logger Function Can Save 10 Yearsâ??Data Including Day, Month And Year
LCD Display Volume, Flow Rate, Flow Direction, Alarm, Leak Detection At The Same Time
Standard RS485 (Modbus-RTU), A Variety Of Options, NB-IOT, OCT, GPRS etc.
Electric Components According To ROHS, OSP Processed Circuit Board
Stainless Steel Body (SS304) is Integrated Stretching Patent Right Product
International Standard Flange Connection, Simple Installation
According To Sanitary Standard For Drinking Water
Manual Water Meter : Watflux is the best in industry for manufacturing and supply of Residential Water Meters. We can provide all kinds and all sizes of water meters. Watflux has variants such as Manual Water Meter, Digital Water Meter and Ultrasonic Water Meter.
Features:
The meter is a positive displacement water meter with bottom load facility
Non-lead bronze meter body
Technical data conforms to awwa c708 standard
Magnetic drive with lower transmission resistance
Easy to read and installation.
Profile
A certain amount of water as defined by meter body passing through makes piston move. The measuring structure records its movements. Movements times defined amount making total amount of water passed registered.
Features
1. Rotary piston structure. It registers total amount of water passed in the tube by calculating how many times the piston rotates.
2. Dry and wet type are both separated from water so as to keep the registering clear.
3. Registering is stable and high-graded measurement. Easy to install.
4. Long endurance with no rotating inclination and long work life.
5. Various types available to register pure water or to be installed in any position.
6. Remote transmission device can be added upon request.
7. Different structures and specifications with beautiful appearances are available.
8. Meter bodies can be of copper, SS or plastic.
9. All technical figures are conformed with GB/T778.1~3-1996 which is equivalent to IS04064 Standard Class C.
Working condition
L Water temperature≤ 45º C
L Water pressure≤ 1Mpa (≤ 0.6Mpa for LXH-8S).
Maximum permissible error
L From the minimum flow-rate (qmin ) inclusive to the lower zone of the transitional flow-rate (qt ) exclusive: ± 5%.
The water enters the meter from the inlet of the meter body and impacts the vane wheel at the tip of the vane blades to make it rotate. The water flows out from the outlet of the body. The rotation of the vane wheel (proportional to the velocity of water flow) is transmitted directly to the central gear in the vacuum-sealed register by the magnetic coupling. The sealed register totalizes and indicates the water volume passing through the meter.
Working condition
-Water temperature≤ 50º C (Hot water meter≤ 90º C)
-Water pressure≤ 1MPa (PN: 1.6MPa/16bar)
-Δ P≤ 0.1MPa
Accuracy
-From minimum flow-rate (qmin) inclusive, to transitional flow-rate (qt), exclusive: ± 5%
-From transitional flow-rate (qt) inclusive, to overload flow-rate (QS), exclusive: ± 2% (Hot water meter: ± 3%.
Features
1. Wet, dry, liquid sealed
2. For hot or cold water
3. Small, light
4. Brass body or plastic body, optional
5. Brass body can be painted or nickel coated
6. High accuracy
7. The meters conform to ISO4064 Standard Class B or Class C.
Multi-jet dry-dial meter for cold water
Nominal flow rate Qn 1.5 to 15 m3/h/ Q3 2.5 to 25 m3/h
EEC approval metrological class BH
MID-type examination certificate R160
Good readability even at extreme
operational conditions
Hermatically sealed counter
Antimagnetic shield (optional)
ELSTER conText inscription system
Features
It is dismountable and its movement can be pulled out easily for repair and exchange without taking the meter from pipe. (The recorder can be replaced on condition that water is available)
The recorder is sealed up so that readings are over clear.
Measuring devices are general purpose and can reduce alternate parts.
Its parts are connected magnetically and work numbly and reliably because of slight obstruction.
The pressure loss is small.
It is durable.
Working Conditions
Cold
Water Temperature: 50C
Water Pressure: 1MPa
P < 0.03 MPa
(APS Marines & Logistics)
Features
It is dismountable and its movement can be pulled out easily for repair and exchange without taking the meter from pipe. (The recorder can be replaced on condition that water is available)
The recorder is sealed up so that readings are over clear.
Measuring devices are general purpose and can reduce alternate parts.
Its parts are connected magnetically and work numbly and reliably because of slight obstruction.
The pressure loss is small.
It is durable.
Working Conditions
Hot
Water Temperature: 90 C
Water Pressure: 1MPa
P < 0.03MPa
Accuracy
From minimum flow-rate (Qmin) inclusive, to transitional flow-rate (Qt),exclusive:
+ 5%
From transitional flow-rate (Qt) inclusive, to overload flow-rate (Qs), exclusive:
+ 2%
Hot: Exclusive: + 3%
Application
Dismountable spiral hot water is for recording discharge, flowing through its pipe. It can not record the amount of polluted water end corrosive liquid
(APS Marines & Logistics)
GMF200-W ultrasonic water meter is designed for water metering settlement and production of a high performance products, with the remarkable features of low power consumption, wide measuring range ratio, stable and reliable measurement .Each component reaches IP68 protection class, to ensure long term operation though water in the inside meter.
120711 Water Meter Suppliers
Short on time? Let Water Meter sellers contact you.