Teflon centrifuge tubes have tube caps to prevent sample leakage, especially for radioactive and highly corrosive sample experiments. It can also prevent the centrifuge tube from deforming. #centrifugetube #samplepreparation #labware
1.Application: Heating water bath, oil bath, etc. 2. Operating temperature: -200â??~+260â??. 3. Features: The inner wall is smooth, corrosion-resistant, and the metal element blank value is low. 4. Main use: Reactor between liquid and solid or liquid. #labware #digestionvessel #labware #flask #teflon
1. Suitable for semiconductor analysis, trace analysis, isotope analysis and other analytical laboratories that have strict requirements on the use of utensils. 2. Good sealing, no leakage, can be stored for a long time, and has a high reuse rate. 3. The metal element blank value is low, the content of lead, uranium, etc. is
Multiple specifications available: 5/10/25/30...1000/2000ml; 1. Corrosion-resistant, especially resistant to hydrofluoric acid. 2. Low background, no dissolution or precipitation. 3. Anti-fall and durable. #cylinder #labware #teflon #electronicgrade
Can be externally connected to a gas washing bottle absorption device to form a reaction device; the bottle cap and bottle body are made of high-purity PFA material, without other impurities; resistant to strong acids and alkali, and high temperature: -200~+260â??; multiple specifications available custom made.
Use acid steam to clean the utensils in countercurrent to clean more thoroughly and avoid cross-contamination.Can be placed on a hotplate to clean the PFA vials and labware by heated soaking in soap solution or acids.All wetted parts are molded from high purity PFA. #teflon #acidcleaningsystem #labware #pfavials #geochemistry
Composed of multiple PFA tubes, PFA valves, PFAVials and two isotope ion exchange columns. Use with digestion instrument for heating. Support customization of various PFA tube combinations.
Available in 30-5000ml, the bottle body and cap are made of high-purity PFA material, resistant to strong corrosion and high temperature: -200~+260. Can store standard chemicals for a long time without leaking. #reagentbottle #teflon #labware #samplingvials
It can be used with separation funnels, stirring plugs, condenser tubes and other vessels to form a distillation and condensation reaction device for the purification of substances. Available in 250ml-3000ml, the number of necks can be customized. Undertake various PFA welding, mold opening and other services. #teflon #flask #Roundbottomedflask #labware #semiconductor #newenergy
25/55/75/100/110ml can be customized, and PFA or TFM materials are optional. Independently produced, the price is more favorable. It can be used with all types of CEM instruments without conflict. #digestiontube
The cover and body are made of high-purity imported PFA material and do not contain other impurities. Resistant to strong acids and alkalis, the utensils can be put into a cleaning tank and soaked in acid for cleaning. #acidcleaning #teflon #labware #icpms
PP, PFA, glass, PTFE, etc. support customization, optional specifications . PTFE digestion tubes are available with a variety of reflux covers, and most other materials are threaded sealing covers.
Multiple specifications available: 10, 25, 50, 100, 250, 500, 1000ml. Compared with glass, it is more resistant to falling and less likely to break, and has a longer service life. The inner wall is smooth and non-stick.
Teflon multi-neck flask, condenser tubeï¼?connected by PFA tube. Can be used for distillation and purification of fluoride. Supports custom fittings and valves.
ppt level sampling bottle, which can be used for pin-type sampling, has excellent air tightness, is made of Telfon (PFA) material, can store standard substances for a long time, and is resistant to strong corrosion. #Wetelectronicchemicals #semiconductor #Electronicgradebottle #Highpurityreagents #PFAvials #labware #geochemistry
microsyringe 1. Thickened glass material, high transparency, accurate scale; 2. Stainless steel metal push rod, sturdy and durable, comfortable feel; 3. Metal inner screw head, tight link, safe and stable;
Plastic Tips for 10 ul, 200 ul, 1000 ul etc.. Optional with sterile, filter, length etc..
NG500 lab use nitrogen generator Product Description NG500 Nitrogen Generators Lab nitrogen gas Working Principle Nitrogen generator uses the electrocatalysis method to separate air gas Stable and pure air enters electrolysis cell and oxygen in the air is separated then left nitrogen gas is outputted Application Carrier gas for various brands of GC and GCMS Make up gas for GC Supplementary gas 3Gas for Gel Permeation Chromatograph 4LCMSLiquid ChromatographMass Spectroscopy and Thermal Analyzer 5Other field that ask pure N2 Features 1 Program control Nitrogen gas could be adjusted automatically according to usage flow under stable pressure and flow 2 Advanced technology It uses noble metal as catalyst high catalytic efficiency and large nitrogen production 3 Twolevel catalysis Oxygen content in nitrogen is less than 3ppm 4 Lower moisture in nitrogen gas Technical Parameters Model NG300 NG500 Output Flow mlmin 0 300 0 500 Output Pressure 042 Nitrogen Purity 99999 compared with O2 Input Air Pressure 04 Power Voltage V 22015Â 50 60Hz Input Power W 110 200 Weight kg
1. Tetrafluoro flasks have single-neck, three-neck and four-neck, 17, 19 and 24 standard ports, and each standard port is equipped with a stopper. 2. It can be disassembled and cleaned, and the inner wall is smooth; 3. Operating temperature: -200+250 4. PTFE round bottom flasks can be processed according to your requirements; 5. The cover and the body, as well as the necks and the cover are connected by threads, which is convenient for disassembly and cleaning
The inner surface is smooth, high transparent and straight with high accuracy. Both normal and low-retention are available for customer to choose. 10 UI Medical grade