Features: 3-part differentiation 23 parameters+3 color histograms Double channel counter Up to 60 samples per hour Volume measurement by time, more  stable  andreliable 8.4 inches high resolution TFT, Windows interface all testing parameter displayed simultaneously Advanced Volve  long lifetime Large storage capacity: up to 10,000 samples Rs232 interface, PC connecting Specification: Principle Impedance for cell counting Cyanide-free method for HGB Parameters WBC, Neu#, Lym#, Mid#, Neu%,Lym%, Mid%, RBC, HGB, HCT, MCV, MCH, MCHC,RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR Histograms WBC, RBC, PLT histogram
1&1/2 meter long consists of two rods on heavy cast iron feets with leveling screws with four heavy riders two sliders have liter motion with lens holder &two needless. (a) OPTICAL BENCH: Same as above but both rods of steel C.P. (b) OPTICAL BENCH: Same as above but both brass covered pipe inside steel rods. (c) OPTICAL BENCH: Same as above but both stainless steel rods.
Read by two opposite verniers reading to one minute of the arc. The objectives used in telescope and collimators are achromatic and provided with rack and pinion focusing arrangement. Telescope arm and prism table are provided with fine and coarse adjustment. The prism table is provided with three leveling screws and is engraved with concentric ring and lines. The scale and verniers are of stainless steel and are machine divided. Cover plate protects the scale from dust and carries two transparent windows for verniers. The instrument is finished in pleasing and smooth duco colour and other necessary parts are chromium plated. With prism clamping device and diffraction grating stand in polished wooden case: a) 5 dia circle reading one minute , b) 6 dia circle reading one minute, c) 6 dia circle reading 30 seconds, d) 7 dia circle reading 30 seconds, e) 9 die circle reading 30 seconds, f) 10 dia circle reading 30 seconds
DSY-004A is designed to determine the kinematic viscosity of liquid petroleum products with a Circular glass bath which accommodates Pinkevitch, Cannon Fenske, and Reverse Flow viscometers, etc (Equipped with Pinkevitch viscometers). DSY-004A has a built-in WinCE based MCU. It not only can control the accuracy of the bath temperature in 0.01 but also can automatically calculate viscosity results by pushing a start-stop input button (No optical sensor detection system). 120 kinds of viscometers constant can be stored and XML format data can be provided with LIMS. 10 inch touch color screen displays the batch temperature. Meanwhile, shows us two viscometers measuring times and its kinematic viscosities.
Brief introduction of jacketed glass reactor: The kettle body is designed by double glazing glass reactor, the inner layer into the reaction solution to do the reaction was stirred interlayer can pass into the type of the cold heat source circulating heating or cooling the reaction can also be used in high temperature, low temperature, or vacuum experiment reflux and distillation of the reaction solution. It is the ideal equipment for primary and secondary schools of modern chemistry experiments, biopharmaceutical and synthesis of new materials. Features about glass reactor: 1. A full set of glassware with GG3.3 borosilicate glass production with good chemical and physical properties 2. Limit temperature of 250C for high temperature experiments, and limit temperature of -60C for low temperature experiments. 3. Titanium ring, new titanium alloy mechanical seal, sealing 0.098Mpa. 4. The PT100 temperature, and is a liquid crystal display. More accurate temperature measurement and more convenient. 5. Frequency control, AC induction motor. Constant speed, brushless, no spark, security and stability, and continuous work. 6. Quality 304 stainless steel all-inclusive PTFE stirring rod and a three-bladed propeller structure. 7. The bottom flanged discharge port with a Teflon value, aluminum parts flange fixed container no dead ends.
Brief introduction of jacketed glass reactor: The kettle body is designed by double glazing glass reactor, the inner layer into the reaction solution to do the reaction was stirred interlayer can pass into the type of the cold heat source circulating heating or cooling the reaction can also be used in high temperature, low temperature, or vacuum experiment reflux and distillation of the reaction solution. It is the ideal equipment for primary and secondary schools of modern chemistry experiments, biopharmaceutical and synthesis of new materials. Features of jacketed glass reactor: 1. A full set of glassware with GG3.3 borosilicate glass production with good chemical and physical properties 2. Limit temperature of 250C for high temperature experiments, and limit temperature of -60C for low temperature experiments. 3. Titanium ring, new titanium alloy mechanical seal, sealing 0.098Mpa. 4. The PT100 temperature, and is a liquid crystal display. More accurate temperature measurement and more convenient. 5. Frequency control, AC induction motor. Constant speed, brushless, no spark, security and stability, and continuous work. 6. Quality 304 stainless steel all-inclusive PTFE stirring rod and a three-bladed propeller structure. 7. The bottom flanged discharge port with a Teflon value, aluminum parts flange fixed container no dead ends.
Brief about glass reactor: The kettle body is designed by double glazing glass reactor, the inner layer into the reaction solution to do the reaction was stirred interlayer can pass into the type of the cold heat source circulating heating or cooling the reaction can also be used in high temperature, low temperature, or vacuum experiment reflux and distillation of the reaction solution. It is the ideal equipment for primary and secondary schools of modern chemistry experiments, biopharmaceutical and synthesis of new materials. Features about glass reactor: 1. A full set of glassware with GG3.3 borosilicate glass production with good chemical and physical properties 2. Limit temperature of 250°C for high temperature experiments, and limit temperature of -60°C for low temperature experiments. 3. Titanium ring, new titanium alloy mechanical seal, sealing 0.098Mpa. 4. The PT100 temperature, and is a liquid crystal display. More accurate temperature measurement and more convenient. 5. Frequency control, AC induction motor. Constant speed, brushless, no spark, security and stability, and continuous work. 6. Quality 304 stainless steel all-inclusive PTFE stirring rod and a three-bladed propeller structure. 7. The bottom flanged discharge port with a Teflon value, aluminum parts flange fixed container no dead ends.
Laboratory Hot Plate With N ylon+GF Work Plate Material
Product Name : Eye Model Product Description : 3 Time enlarged, dissectable into 7 parts.
Vernier Callipers with Digital Read Product Description : Conversion button, on/off switch and zero setting switch. Metal knob for locking the device is provided at the top.
Micrometer with rachet stop, dull chromium plated brass body, accurately threaded M.S.. rod. Zero Correction screw is provided at one end of the body. Packed individually in beautiful printed duplex box. Pitch 1mm Avaialble : 10 / 15 / 20 / 25 mm
For taking direct readings. The micrometer is provided with mm/ inch conversion button, on/off switch and zero setting switch. Lever for locking the device is provided at upper part of the body. Battery compartment is at the back of the body.
Brass scale and disc, base fitted with threaded rod and legs,packed duplex box. L.C.1/100mm
Heavy and superior quality packed in printed duplex box. L.C.1/100mm
Tested, presented in seasoned cabinet polished velvet lined box packed in printed duplex box. Avaialble : 50 / 100 / 200 gms
Brass NP, cabinet polished wooden box, duly tested, packed in printed duplex box. Avaialble : 50 / 100 / 200 / 500 / 1000 gms
Iron Black painted set of five including hanger
Iron Black painted set of five including hanger A 500 gms x 5 2.5 kg B 1000 gms x 5 5.0 kg
Tubular body in card box. Avaialble : 50 / 100 / 200 / 500 gms
Smith type, fly back action, metal body with new machine. Stop Start Lever at right side. Left side has lever to bring the needle to zero after mechanism has stopped. Least Count = 1 sec.