Iron Black painted set of five including hanger
A 500 gms x 5 2.5 kg
B 1000 gms x 5 5.0 kg
For general laboratory use for various experiments. Made of polished brass, each mass has a standard keyhole slot to retain on hanger. Each mass and hanger is stamped with its own value
Supplier: All kinds of scientific goods and laboratory products like slotted weights, oven, incubators, rheostat, potentiometer
Services: Manufacturer
Supplier: Organ bath, rotating drum, suppository molds, pensky martin flash point apparatus, soxhlet apparatus, tablet hardness tester, tablet coating pan, tablet disintegration unit, chemistry lab equipment : burners, retort stand, thermometer, porcelain ware, slotted weight, wire gauge, physics lab equipment : compass, meters, spectrometer, lens mirror prism, micrometers screw gauge, vernier calliper, biology lab equipment : dissecting set, microscope slides, microtome, magnifier, microslide cabinet, spatula, automatic polarimeter
Supplier: Slotted, analytical, physical - weight box, burners and gas taps, pendulum bobs: (set of six metals), retort stand, clamps & all type of mechanics apparatus , fly wheel, torson pendulum
Spring Constant App.Provided with half meter scale, spring with pointer and slotted weights, fitted on nicely painted iron base
For verifying the relation between forces acting at a point, provided with two clamp type pulleys for mounting at any position, 45cmx30cm board wall type, complete with 3 sets of 50gmx5 iron slotted weights
39- liters laboratory flotation machine is applied in ore dressing by the method of laboratory floating. It is concatenation floatation machine with several sets of machines. And the number of chutes is even from 1 to 10. It is left-type or right-type according to user's demand. Structure and features: Laboratory flotation machine with 39 liters is impeller mechanical flotation machine. It is composed by the following main parts: (1). Tank The tank 1 is welded with steel plate, using the impeller to stir, simultaneously inflating the air into pulp. In order to adjust the thickness of slurry surface in tank and foam layer scraped, the intermediate tank 15 is made up of two slot panels, in which is the pulp surface regulator 5 installed, orifice 17 is installed on the tank cover 14, which is used to prevent the chaotic movement of pulp affects on the bubble zone, the gangue is entrained mechanically to the concentrate. Basin liner 6 is equipped in the tank to prevent the tank bottom worn, basin liner can be replaced. Discharging port 8 is placed outside the tank bottom, which is used to storage water when cleaning. The pulp flows into the intermediate tank 15 and the end tank 3 from the overflow port on the panel, the catheters of the intermediate tank bottom and the cover 14 on the groove wall bottom are put into the next tank, which will flow continuously through all the tanks of flotation machine. The pulp is fed from the feed chute 3, is discharged from the discharging port 8 of the tailing 1, the feed port 16 is equipped in front and at the back of tank bottom, which is easy to change the technological process. (2)Impeller system Impeller system is installed in the center of the flotation tank, the vertical arrangement coiled impeller 9 which leaves are up is fixed at the bottom of the impeller shaft 10 and around the vertical shaft tube 12. The tube top is located over the pulp stone and foam layer, the tube bottom is bearing the cover 14. When the impeller rotates, the quantities of air can be absorbed along the vertical tube 12. The protective plate 4 is fixed under the cover 14, the gap between the protective plate and impeller is related to the aeration rate, its maximum gap is less than 3mm, if the gap is too large, it is necessary to replace the protective plate or be adjusted appropriately. The hole of vertical tube 12 is used to cycle pulp, and make the pulp and air mix well. The upper of the impeller shaft rotates in the rolling shaft 11 installed in the bearing shell, the bearing shell is installed on the beam 7. The pulley fixed at the top of the shaft makes the motor 18 rotating through the triangle belt, of which the tension can be adjusted by the nut 19. (3). Shaving foam device Foam is scraped using the rotary scraper along the flotation machine, scraper 20 is installed out of the discharging port. The pulley is installed at the end of the scraper shaft, which rotates through the driving of the worm reducer 21 and V-belt. Technical parameters (1)Tank size: L¡ÁW¡ÁH 315¡Á315mm¡Á527mm (2)The effective volume: 39 liters (3)The flow of the pulp is calculated according to the production capacity (4)Aeration rate: 35-45 liters / min (5)Impeller diameter:200mm (6)Impeller speed: 809m/s (7)Impeller circumferential speed:8.14m/s (8)Scraper rpm: big wheel/small wheel 21r/min /13r/min (9)Motor: Model y900l-4 voltage :220/380V. Power:1.5KW rpm: 1400 r / min (10)Assembly method: Left-style (11)The outline size of machine: H: 930mm, W: 762mm, L (including 2 slots)1081mm (12)Total weight:(including 2 slot motors).
SPECIFICATIONS: Wavelength Range: 190-900nm Wavelength Accuracy: ±0.25nm Resolution: Two Spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30% Baseline Stability: Background correction: The D2 lamp background correction capability at 1A is better than 30 times. !0.004A/30min. Light Source: Lamp turrel: 6-lamp turret RIC-114/ RIC-113 4-lamp turret RIC-112 Auto-alignment, fully automated scan and peak-picking Lamp current adjustment: Automatic adjustment and display. Wide pulse current: 0~25mA Narrow pulse current: 0~10mA Lamp power supply mode: 400Hz square wave pulse 100Hz Narrow square wave pulse + 400HzWide Square wave pulse (RIC-114/ RIC-113) Optical System: Monochromator: Single beam, Czurney-turner design grating monochromator Grating: 1800l/mm Focal length: 277mm Blazed wavelength: 250nm Spectral bandwidth: 0.1nm, 0.2nm, 0.4nm, 1.2nm automatic change Flame Atomizer: Burner: 10cm single slot all-titanium burner Spray chamber: Corrosion resistant all-plastic spray chamber Nebulizer: High efficiency glass nebulizer with metal sleeve, sucking up rate:6-7mL/min Detection and Data Processing System: Detector: R928 photomultiplier with high sensitivity and wide spectral range Software:Windows Operating System Analytical method:Window curve auto-fitting; standard addition method; automatic sensitivity correction, automatic calculation of concentration and content. Repeat times: Maximum 20 times of repeat measurement, automatic calculation of mean value, standard deviation and relative standard deviation Multi-task function: Sequential measurement of multi-elements in one sample Condition reading:With model function Result printing: Measurement data and final analytical report printout, editing with excel. Standard RS-232 serial port communication Characteristic Concentration and Detection Limit: Normal Air-C H flame: Cu Characteristic concentration Rich oxygen Air-C H flame: Ba: Characteristic concentration Function Expansion: Hydride vapor generator can be connected for hydride analysis. Dimensions and weight: 1020 (L) X 490 (W) X 540 (H) mm (main unit), unpacked 80 Kg. Dimensions and weight: 1020 (L) X 490 (W) X 540 (H) mm (main unit), unpacked 80 Kg.
The demostration meter is used to demostrate the working principle of AC and DC Ammeter, Voltmeter and Galvanometer with the help of interchangeable plastic Scales. Amagnetically damped spring controlled moving coil movement is housed in a plasic case with glass front and rear panel. A pair of 4 mm socket terminals is give on the right side to apply voltage and current. A special locking arrangement and a centrl / side zero adjustment control is given on the left side with the help of two knobs. The interchageable scales are boldy marked on both sides enabling the class to view from the front and the demostrator from the rear. Each scale is fitted through a slot on the right side of the case and has a plug connector which also serves to locate and align the scale positively in position. Locking system is provided to lock the pointer to aovid damage is transist. Basic Movememt : 5mA - 100 m V F.S.D. Scale Lenght : 200 mm approx. Accuracy : ± 2.5 % F.S.D. Dimensions : 300 x 150 x 300 mm approx. Weight : 2 kgs. approx. Supplied with three standard scales.