1.Sharp stereo erect image over a wide field of view. 2.45 inclined and 360 rotational binocular head with locked-in eyepiece.The left ocular-tube with diopter adjustment +5dp,The interpupillary distance is between 55-75mm 3.Zoom objective 1x-4x 4.ZTX-E series supplied with pillar style stand, ZTX-E-W series supplied with arm curved style stand.ZTX-3E series trinocular head. 5.Electric apparatus has CE approval 6.Power supply 110V/60Hz or 220V/50Hz 7.Each set packed in styorfoam and in an inner box.Three sets in one carton 8.A wide range of optional accessories. Optional accessories: 1.Eyepiece WH5x(+22mm),WF10x(+23mm)WF15x(+13mm),WF20x(+10mm) 2.Auxiliary objective 0.5x,0.75x,1.5x,2x 3.Figure eyepiece:VD-TV,VD-PC 4.Darkfield stage,+95mm 5.White/black working plate,+95mm 6.Fluorescent bulb 5W 7.Halogen bulb 12V/10W/LED 8.Ring fluorescent lighting 8W & 10W 9.Wooden cabinet with lock and key /Aluminium case Each set packed in styorfoam and in an inner box.Three sets in one carton
Laboratory glassware Laboratory glassware manufacturing a 3.3 borosilicate glass Packind in hard cartoon box
Pathological and diagnostic solutions .
Specialty Adhesives, Digital Moisture Meter..
General lab equipments, laboratory medical consumables.
Lab furniture and equipment.
IVD products, rapid test, elisa kit, laboratory plastic consumables.
Antibodies, viral antigens, innovative diagnostic components, and critical assay reagents .
Laboratory glasswares and chemicals.
The ASTM E595 test is mainly derived from NASA and is a gas release test conducted in a vacuum environment. Under vacuum conditions, material venting and structural venting are common phenomena that have a significant impact on the normal and stable operation of high-tech equipment and aviation components. We have rich experience in these materials, including: thermal conductive silica gel, thermal conductive silicone rubber, copper clad laminate, fluororubber dust plug FKM, electromagnetic shielding film, EPDM protective plug, dust plug, adhesive, optical adhesive, hot melt adhesive, thermal conductive gel, SMC grid plate, TPU fire proof and anti-static elastomer, plastic, PP, PC, paint baking steel plate, PCD, etc ASTM E595-15 Outgassing test - Test Standard ASTM E595 Standard Test Method for Total Mass Loss and Collected Volatile Condensable Materials from Outgassing in a Vacuum Environment ASTM E595-15 Outgassing test - Test Requirement CVCM ï¼?collected volatile condensable materialsï¼?â?¤0.1% TML ï¼?total mass lossï¼?â?¤1% WVR ï¼?the amount of water vapor regainedï¼? Outgassing test ASTM E595 - Test Conditions Pre Condition: 73 F/ 50% RH (24Hours) ; Post Condition: 73 F/ 50% RH (24Hours) This test method describes the test apparatus and related operating procedures for evaluating the mass loss of materials being subjected to 125�°C at less than 7*10â??3 Pa for 24 h. The overall mass loss can be classified into noncondensables and condensables. The latter are characterized herein as being capable of condensing on a collector at a temperature of 25�°C. More about Outgassing test ASTM E595,please contact us :
These includes all types of glass containers used in a laboratory, from beakers and flasks to pipettes and test tubes.
Material is borosilicate glass and PP,the normal color is clear and amber.Suitable for HPLC and GC.Has wide application area,it's including food,consumer goods,pharmaceutical,environmental,medical,chemical materials,packing and etc testing. It's economic and convenient suitable for use in Shimadzu VP series, rack 16,Borosilicate glass,olyethylene,Starburst top feature for easy needle penetration,Cap to be packed separately from vials
Material is borosilicate glass and PP,the normal color is clear and amber.Suitable for HPLC and GC.Has wide application area,it's including food,consumer goods,pharmaceutical,environmental,medical,chemical materials,packing and etc testing. It's economic and convenient suitable for use in Shimadzu VP series, rack 16,Borosilicate glass,olyethylene,Starburst top feature for easy needle penetration,Cap to be packed separately from vials
Material is borosilicate glass and PP,the normal color is clear and amber.Suitable for HPLC and GC.Has wide application area,it's including food,consumer goods,pharmaceutical,environmental,medical,chemical materials,packing and etc testing. It's economic and convenient suitable for use in Shimadzu VP series, rack 16,Borosilicate glass,olyethylene,Starburst top feature for easy needle penetration,Cap to be packed separately from vials
The ZRS-3H Glow-wire Test Apparatus is according to IEC60695-2-1, IEC60695-2-10, IEC60695-2-11, IEC60695-2-12, IEC60695-2-13 (GB/T5169.10, GBT5169.11, GBT5169.12, GB/T5169.13) < Basic testing methods of Glow wire, basic testing methods of Glow wire device>, UL 746A, IEC829, DIN695 and VDE0471.What is glow wire test? The Glow wire tester ZRS-3H/ZRS-3HS is suitable for resistance to abnormal heat and fire test on lighting lamps, electronic products and household appliances. It uses high-temperature coating spraying on steel structure and imported instrument display, with easy operation and stable performance. The glow wire testing equipment is applicable to flame resistance test of all levels of QC departments and corresponding enterprises.Specifications: â?¢ Heating temperature: adjustable continuously within the range of 25~1100�°C, the accuracy of temperature is 1�°C, the resolution of temperature is �±3�°C â?¢ Glow-wire time: 0.1-999.9sï¼?�±0.1s(time range is adjustable) â?¢ Ignition time: 0.1-999.9s, auto record, manual pause â?¢ Flame-out time: 0.1-999.9s (auto record and manual pause) â?¢ Glow wire pressure on test specimen: 1�±0.2N. Limiting pressure depth is 7mm â?¢ Glow wire: �?4 nickel (80ï¼?) and chromium (20ï¼?) Made in specific dimensions. â?¢ Thermocouple: �?0.5 armored nickel & chromium/nickel-chromium wire, K Type. â?¢ Automatic departure: While reaching specified glowing time, test specimen will depart from glow wire automatically.To save the delivery cost for the oversea market, LISUN designed a compact version glow-wire tester weighing less than 50kg. (Customer need to prepare additional ventilation system for ZRS-3HS) What is glow wire capable? The glow wire tester uses simulation technology to evaluate the fire hazard caused by thermal stress caused by heat sources such as hot components or overload resistors in a short period of time. It is one of the series of electrical and electronic components fire hazard test instruments. It is suitable for evaluating the flammability test and light-off temperature test of electrical equipment and its components and parts, as well as solid electrical insulating materials or other solid flammable materials.
Original Hydro Flask Bottles available to order. Entire range
Salt Spray Test Chamber | Salt Fog Test | ASTM B117 Salt Spray ChamberSalt Spray Test Chamber is applicable to the salt spray corrosive test for the protection layer of components, parts, electronic and electrical parts and metal materials and industrial products. The salt fog test chamber meets the following standards: IEC60068-2-11 (GB/T2423.17), GB/T10125, GB/T1771, ISO9227, ASTM-B117, GB/T2423-18, QBT3826, QBT3827, IEC 60068-2-52, ASTM-B368, MIL-STD-202, EIA-364-26, GJB150, DIN50021-75, ISO3768, 3769, 3770; CNS 3627, 3885, 4159, 7669 etc. Specifications: A waterproof structure is adopted between the chamber cover and chamber body, thus there is no salt spray overflow. Adopts the tower spraying system and equipped with the salt solution filter system and non-crystal nozzle so as to realize even salt spray distribution and freely adjustable settlement. The Salt Spray Chamber Working room temperature range:RT+5C~50C (The setting value cannot be lower than the current ambient temperature); Saturated barrel temperature: +40C~+63C;
Product Description Our organization FITZER has gained recognition as the affluent manufacturer and supplier of a qualitative range of U Tube Absolute Pressure Mercury Filled Manometer. The offered manometer is designed by our adroit professionals using the best quality components and sophisticated technology in sync with industry standards. We guarantee our clients that this manometer is tested on varied parameters in order to ensure its flawlessness. Clients can avail this manometer from us at nominal prices. Features: Flawless finish Easy to operate Sturdy construction Specifications: Model: FITZER / UAPI / 76 Ranges:50-0-50 & 500-0-500 mm of Hg Resolution: 1 mm Of Hg Catalogue
Glass Tube Rotameter is a Variable Area Flow Meter. A rotameter consists of a tapered tube, typically made of glass, with a 'float' made of SS or PTFE. The differential pressure across the annulus area is constant. The float moves through the tapered tube up and down with respect to fluid flow. The vertical position of the float as indicated by scale is the measure of the instantaneous flow rate. Specifications : Material of Construction : CS / SS 304 / 316 / PTFE Float : SS 316 / SS 304 / PTFE Tube : Glass Borosilicate Packing : PTFE / VITON / Silicon / Neoprene Enclosure : SS Buffed / MS Powder Coated / FRP Line Size from 15 NB to 80NB Ranges between 2.0 LPH to 2SQ00LPH ace-To-Face Distance : 500mm Accuracy : +/- 2% of Full Scale Measuring Span : 1:10 Scale : Acrylic / Aluminum / SS Various Features : Heavy Duty Design with Maximum Visibility Two Tone Powder Coated Excellent Finish No Threads in Body, Avoids Corrosion Easy to Maintain and Replace Suitable for on Line Installation Single Piece (Joint-less) PTFE/ PFA/ PP cladded end connections
Metal tube Rotameters are variable area flowmeters for measuring volumetric flow rates of liquids and Gases. The construction includes a tapered stainless-steel tube. A float with a magnet embedded in it, moves inside a tapered tube. The float is magnetically coupled with an indicating pointer assembly. The float position inside the tube is result of balancing of buoyancy and gravitational force. As flow tube is tapered from inside, gap is created between inside wall of tapered tube and the outer diameter of float and fluid flow passes through it. As the float moves vertically up and down inside the tube, the magnetic coupling moves the indicating pointer assembly which is indicates the flow rate. An analog electrical output of 4-20 mA which is proportional to fluid flow rate can be offered in Metal tube Rotameter. A Hall effect sensor senses the position of pair of magnets mounted on shaft assembly. As the analog pointer rotates the output of the Hall effect sensor varies. This output is processed by an electronic circuit to give current output proportional to flow rate. Electrical Transmitter version is available in various versions suitable for applications in safe and hazardous areas. Two wire Loop powered 24 DC supply Output: 4-20 mA HART communication output (Optional) CE / ATEX certifications IP 65 construction as standard