The ASTM E595 test is mainly derived from NASA and is a gas release test conducted in a vacuum environment. Under vacuum conditions, material venting and structural venting are common phenomena that have a significant impact on the normal and stable operation of high-tech equipment and aviation components.
We have rich experience in these materials, including: thermal conductive silica gel, thermal conductive silicone rubber, copper clad laminate, fluororubber dust plug FKM, electromagnetic shielding film, EPDM protective plug, dust plug, adhesive, optical adhesive, hot melt adhesive, thermal conductive gel, SMC grid plate, TPU fire proof and anti-static elastomer, plastic, PP, PC, paint baking steel plate, PCD, etc
ASTM E595-15 Outgassing test - Test Standard
ASTM E595 Standard Test Method for Total Mass Loss and Collected Volatile Condensable Materials from Outgassing in a Vacuum Environment
ASTM E595-15 Outgassing test - Test Requirement
CVCM ï¼?collected volatile condensable materialsï¼?â?¤0.1%
TML ï¼?total mass lossï¼?â?¤1%
WVR ï¼?the amount of water vapor regainedï¼?
Outgassing test ASTM E595 - Test Conditions
Pre Condition: 73 F/ 50% RH (24Hours) ; Post Condition: 73 F/ 50% RH (24Hours)
This test method describes the test apparatus and related operating procedures for evaluating the mass loss of materials being subjected to 125�°C at less than 7*10â??3 Pa for 24 h. The overall mass loss can be classified into noncondensables and condensables. The latter are characterized herein as being capable of condensing on a collector at a temperature of 25�°C.
More about Outgassing test ASTM E595,please contact us :
ASTM E595-15 Outgassing test - Test Standard ASTM E595 Standard Test Method for Total Mass Loss and Collected Volatile Condensable Materials from Outgassing in a Vacuum Environment ASTM E595-15 Outgassing test - Test Requirement CVCM collected volatile condensable materialsï 0.1% TML total mass loss WVR the amount of water vapor regained Outgassing test ASTM E595 - Test Conditions Pre Condition: 73 F/ 50% RH (24Hours) ; Post Condition: 73 F/ 50% RH (24Hours) This test method describes the test apparatus and related operating procedures for evaluating the mass loss of materials being subjected to 125 C at less than Pa for 24 h. The overall mass loss can be classified into noncondensables and condensables. The latter are characterized herein as being capable of condensing on a collector at a temperature of 25 C. ASTM E595-15 Outgassing test Brief Many types of organic, polymeric, and inorganic materials can be tested. These include polymer potting compounds,foams, elastomers, films, tapes, insulations, shrink tubings, adhesives, coatings, fabrics, tie cords, and lubricants. The materials may be tested in the condition or prepared for test by various curing specifications. More about Outgassing test ASTM E595
ASTM E595-15 Outgassing test - Test Standard ASTM E595 Standard Test Method for Total Mass Loss and Collected Volatile Condensable Materials from Outgassing in a Vacuum Environment ASTM E595-15 Outgassing test - Test Requirement CVCM collected volatile condensable materials 0.1% TML total mass loss 1% WVR the amount of water vapor regained Outgassing test ASTM E595 - Test Conditions Pre Condition: 73 F/ 50% RH (24Hours) ; Post Condition: 73 F/ 50% RH (24Hours) This test method describes the test apparatus and related operating procedures for evaluating the mass loss of materials being subjected to 125 C at less than 7*103 Pa for 24 h. The overall mass loss can be classified into noncondensables and condensables. The latter are characterized herein as being capable of condensing on a collector at a temperature of 25 C. ASTM E595-15 Outgassing test Brief Many types of organic, polymeric, and inorganic materials can be tested. These include polymer potting compounds,foams, elastomers, films, tapes, insulations, shrink tubings, adhesives, coatings, fabrics, tie cords, and lubricants. The materials may be tested in the as-received condition or prepared for test by various curing specifications. More about Outgassing test ASTM E595,please contact us :
ASTM E595-15 Outgassing test - Test Standard ASTM E595 Standard Test Method for Total Mass Loss and Collected Volatile Condensable Materials from Outgassing in a Vacuum Environment ASTM E595-15 Outgassing test - Test Requirement CVCM ï¼?collected volatile condensable materialsï¼?â?¤0.1% TML ï¼?total mass lossï¼?â?¤1% WVR ï¼?the amount of water vapor regainedï¼? Outgassing test ASTM E595 - Test Conditions Pre Condition: 73 F/ 50% RH (24Hours) ; Post Condition: 73 F/ 50% RH (24Hours) This test method describes the test apparatus and related operating procedures for evaluating the mass loss of materials being subjected to 125�°C at less than 7*10â??3 Pa for 24 h. The overall mass loss can be classified into noncondensables and condensables. The latter are characterized herein as being capable of condensing on a collector at a temperature of 25�°C. ASTM E595-15 Outgassing test â?? Brief Many types of organic, polymeric, and inorganic materials can be tested. These include polymer potting compounds,foams, elastomers, films, tapes, insulations, shrink tubings, adhesives, coatings, fabrics, tie cords, and lubricants. The materials may be tested in the â??as-receivedâ?? condition or prepared for test by various curing specifications. More about Outgassing test ASTM E595,please contact us : CASfire Technical Co.,Ltd 8F Building 4, Chinese Academy of Science, No.255 South Duiying Road,Jimei, Xiamen 361021, China Tel: (+86) 0592-3500085 MP: (+86) 18906059211 Email: info@casfire.cn Website: http://www.casfire.cn
1. Application Ultraviolet aging test chamber uses ultraviolet lamp as light source. By simulating the ultraviolet radiation and condensation in natural sunlight, accelerated weatherability test of materials is carried out to obtain the results of weatherability of materials. It can simulate the environmental conditions such as ultraviolet, rain, high temperature, high humidity, condensation and darkness in natural climate. By reproducing these conditions, it can merge into a cycle and let it automatically execute the number of cycles. 2. Standards Conforms with ASTM G 153, ASTM G 154, ASTM D 4329, ASTM D 4799, ASTM D 4587, SAE J2020, ISO 4892, all current UV aging test standards. GB/T14522-93 National Standard of the People's Republic of China--Accelerated Test Method for Plastics, Coatings and Rubber Materials for Machinery Industry Products-Artificial Climate GB/T16585-1996 National Standard of the People's Republic of China-Test Method for Artificial Climate Aging of Vulcanized Rubber (Fluorescent Ultraviolet Lamp) GB/T16422.3-1997 standard design and manufacture of plastic laboratory light source exposure test method. 3. Product Parameters Standard Configuration Editor For Test Box (1) Install 8 UV ultraviolet lamps on both sides of the studio. (2) Sample holder number: 20 pieces. (3) Sample holder size: 404 x 105 (mm) (4) The heating mode is inner tank water heating, fast heating and uniform temperature distribution. (5) The drainage system uses the return vortex type and U type sedimentation device to drain the water. (6) The distance between the surface of the sample and the ultraviolet lamp is 50 mm and parallel. (7) The actual workroom is made up of test samples and brackets. (8) Internal water level automatic replenishment. (9) The box cover is bidirectional flip type, easy to open and close. (10) The bottom of the test box adopts high quality and fixed PU wheel. 4. Power Supply Condition Editor Power requirements: AC380V ± 10% 50 ± 0.5Hz three-phase five wire system. Preinstalled power: total power +2.0KW Users are required to install air or power switches for the equipment at the installation site.
1. Application Salt spray corrosion test box is designed for surface treatment of various materials, including metal plating, hardware, electronic components, chemical coatings, baking paint, automobiles, motorcycles, hardware sanitary ware, screws, springs, magnetic materials, organic and inorganic skin film, anodic treatment, rust-proof oil and other industries, testing the quality of its products and its corrosion resistance. 2. Standards Conforms to ASTM G85-02 and GB/T2423.17 test standards. 3. Performance parameters Laboratory volume: 108 L, studio size: 600 * 450 * 400 mm Laboratory temperature: 35 ~ 0 The temperature of the saturated air cylinder is 47 to 63. Maximum capacity of test fluid: 15 L External dimension: 1075 * 630 * 1185 mm Can be customized according to customer requirements.
Concrete Testing Equipment Products Aggregate Testing Bitumen Testing Cement Testing Concrete Testing Soil Testing Surveying Equipment Strength Of Material Testing POY Testing Instruments Carbonation chamberThermal conductivity test apparatus of AAC BlocksFreeze-Thaw Chamber (ASTM C666)Accelerated Curing Tank Air Enterainment MeterCompaction Factor ApparatusDigital Compression Testing MachineFully Automatic Concrete Cube Compression Testing MachineCompression testing machine - Channel TypeCompression Testing Machine - Hand Operated Pillar typeConcrete Mixer - Laboratory TypeConcrete PenetrometerConcrete Permeability ApparatusConcrete Test HammerConcrete ThermometerCube MouldCylindrical MoldsExtensometer Fill Box for SCC TestFlexural Testing MachineFlow TableHydraulic Jack J Ring ApparatusLateral ExtensometerLongitudinal CompressometerNeedle Vibrator O Funnel ApparatusPoint Load Index TesterSlump Test ApparatusTile Abrasion TesterTile Flexural Testing Machine U Box V Funnel ApparatusVee Bee ConsistometerVibrating TableVolume Change Apparatus
STANDARDS : EN 196-3,ASTM C187-C191,AASHTO T129-T131,BS 4550 Movements along X Y Z axes Up to 30 different test types may be programmed and over 1000 tests may be memorized. PC Port Initial and fi nal setting time (in 0.1 mm) Automatic cleaning of the needle Automatic stop and storage of measurements for up to 50 tests Plunger for initial consistency Thermostatic baths (optional) Display for data input and diagram/test report Printer for final test report and diagram RS 232 serial port for PC connection Moulds and further needles have to be ordered separately, according to the various standards Power supply: 220 V, 50 Hz, single phase Dimensions: 355 x 620 x 580 mm Weight: 40 kg. Dimensions: 355 x 620 x 580 mm Weight: 40 kg
Conforms to is: 10050-1981, & astm d 4644 This apparatus is used to assess the resistance offered by a rock sample to weakening and disintegration when Subjected to drying and wetting in a slaking fluid, usually water. The equipment meets the essential Requirements of is:10050 -1981 & astm d 4644 and comprises the following: A motor drive with reduction gear mounted on a base board and capable of rotating four drum assemblies at a Constant speed of 20 rev/min approximately. The motor drive is totally enclosed in a hinged cover for quick Accessibility. An operating switch is provided in the cover. Two / four test drums made of brass wire mesh, with one end closed and having a removable cover on the other End. They have suitable couplings for mounting in the perplex water troughs. The drums are 140 mm in diameter And have an unobstructed length of 100 mm. Two / four perplex water troughs, accommodate one test drum each. These drums carry quick couplings on either End which are in turn coupled with couplings of the motor drive. The troughs allow 40 mm unobstructed clearance Below the test drum. A water level mark is provided in each water trough 20 mm below the axis of rotation of the Drum. Suitable for operation on 220 volts, 50 hz, single phase ac supply. Order code Lisc-557a Lisc-557b No. Of test drums 2 4
Oscillating disc rheometer of ektron tek!|s is designed in accordance with astm d2084& iso 6502 standards. More than 30 items of data, such as ml, mh, ts, tc and cri etc. It could be taken from each test. Cure curve provides the processing, vulcanizing, and vulcanized physical properties of rubber cross-linking reaction.