Pt100 Elements -
.Thermocouple -
Differential Pressure Sensor -
.Differential Pressure Transmitter -
.pH Transmitter -
GP Systems has developed flow sensing and indicating system suitable for flow measurement of gases (corrosive or non corrosive), air, and liquids . We use reputed american sensors to ensure most accurate sensing of flow. The system is made in such a way to ensure long life and ease of use. It can measure the flow even a t low pressures and even if there is moisture in the gas/ air. Features: ï?· Most accurate system of flow measurement ï?· Selectable units like lpm, m 3 /min etc ï?· Optional relay output ï?· Optional retransmission function ï?· No effect of moisture or dust in pipeline System Specifications: Measurement Principle: Differential pressure Indicates: Flow Rate and Total Volume Working gas temperature: -25 to 125C Display: LCD/LED 4 digit flow rate, 10 digit total volume Line Pressure: 50mmWC to 300bar Orifice specifications: As per drawing Recording of parameters: Optional Accuracy of system: Better the 1% Communication interface: RS232/ RS485 (Optional) Line Size: From 4mm to 40 inches Power Supply: 220 V AC -
.Bio Gas And Producer Gas Flow Meter -
Key Features: 1.Very low pressure measurable without long-term drift 2.Rugged design 3.Maintenance free 4.Over-pressure protected Key Specifications: 1.Measuring range: 0 ~ 25 Pa to 0 ~ 1000 Pa 2.Maximum static operating pressure: 1.0 bar 3.Maximum safe pressure: 1.7 bar 4.Straight line error (max.): 1.0 % Full scale 5.Pressure connection: screw clamp connectors (aluminum) for 6/4 mm or 8/6 tube 6.Repeatability: 0.1 % full scale 7.Operating ambient & media temperature: -10° C to +70° C 8.Protection class: IP65 per DIN EN 60529 9.Linearity: < 2% Full scale 10.Electrical output: 4-20mA linear, 2 â?? wire 11.Power supply: 24 V DC 12.Material, housing: Polyamide PA 6,6 13.Materials, media contact: Silicon, PVC, aluminum, brass Application areas: 1.Filter status / condition monitoring 2.Precision air duct measurement 3.Clean room pressure balance monitoring 4.Burner air feed low pressure detection 5.Oven air feed control Industrial areas: 1.Air conditioning and ventilation systems 2.Auditorium, office, conference rooms 3.HVAC and ventilation application 4.Environment monitoring 5.Clean room and laboratory rooms
Key Features: 1.Measurement range 0 ?? 1 bar 2.Static operating pressure 25 bar 3.Diaphragm and sealing of Viton 4.Operating voltage 24 V DC/AC 5.Output signal 4-20 mA square rooted 6. 3 ½-digit LED display 7.ECCN: N AL: N 8.Robust design with high repeatability 9.Over pressure protection 10.Wear free non-contact LVDT sensing element, thus no maintenance 11.Signal output with possibility of various characteristic curve 12.Characteristic conversion of output via3?¦.30 entries table 13.Complete set-up of all parameters and print out by using optional PC programming interface EU03 Applications areas: 1.Volume flow monitoring of lubricants oil, mill oil 2.Gearbox lubricant flow monitoring 3.Flow measurement ?? lubricants, oil, hydrocarbons, water, gases Industrial areas: 1.Cement plants 2.Nuclear plants, coal or gas fired power plants 3.hydro power plants 4.Manufacturing and chemical plants
Key Features: 1.Configurable pressure display units 2. 2 independent limit switches with many configuration options 3.Analog signal output with possibility of characteristic curve spread, curve reversal and offset setting 4.Characteristic curve implementation via table with max. 30 measuring points 5.Complete configurable parameters and measuring point protocol possible through optional transmitter PC interface Key Specifications: 1.Relative pressure Measuring range: 0 ~ + 1.6 bar to 0 ~ +60 bar Overpressure: 4 bar ~ 200 bar Burst pressure: 7 bar ~ 250 bar Characteristics curve deviation: 0.5% FS or 1.0% FS 2.Vacuum and ± measuring ranges: Measuring range: 0 ~ (-) 1.0 bar to (-) 1 ~ +24 bar Overpressure: 4 bar ~ 100 bar Burst pressure: 7 bar ~ 150 bar Characteristics curve deviation: 1.0% Full scale 3.Permissible ambient temperature: -10° C ~ +70° C 4.Permissible media temperature: -10° C ~ + 70° C 5.Protection class: IP65 per DIN EN 60529 6.Non-linearity: < 1.0% full scale 7.Hysteresis: < 0.5% full scale 8.Power supply: 24 V AC/DC 9.Analog output signal: (0) 4-20mA / 0-10V 10.Output contacts: 2 potential free relay contact (32V AC/DC , 2A) or semiconductor switches (3~32 V AC/DC, 0.25A), configurable 11.EMC: EN 61326-1:2013, EN 61326-2:2013 12.Material (housing): stainless steel 1.4301 13.Process connection (media contact): stainless steel 1.4404 14.Measuring diaphragm: ceramic 15.Display: 4..6 digit LCD, full graphic, color changing 16.Configurable: attenuation, switching output, measuring range unit, output signal, zero point stability, implementation of characteristic curve, password Application areas: 1.Pump Control system 2.pump and compressors monitoring 3.Filling level measuring Industrial areas: 1.Process engineering 2.Environment engineering 3.Renewable energy eg. biogas etc 4.Waste Water Engineering 5.Effluent treatment 6.Breweries, alcohol industry
Key features: 1.Catalytic bead based pellistor sensor cell with low flash energy 2. 10-bit microprocessor control unit 3.Non-intrusive one man calibration via hall effect switches 4.Atex certified explosion proof / flameproof, suitable for zone 1, 2 gas explosion installation 5.Linear, proportional analog industry standard current output 6.Continuous system self-diagnosis with watch dog 7.Flashback arrestor with sintered filter 8.Auto zero point tracking to zero point compensation 9.Sil 2 hw tuv certified 10.Rs485 serial interface with modbus rtu communication (optional) 11. 1 or 3 relay output module (optional) 12.System and alarm led indicators (optional) 13.Modbus rtu communication over rs485 serial interface Technical specifications: Measuring parameters: hydrogen gas flammability or leakage Sensor technology: catalytic bead based pellistor sensor cell Measuring range: 0 ~ 100 % lel ( 0 ~ 4% v/v @ stp) Response time (t90): < 30 sec Control unit: 10 bit microprocessor based Warm up time: < 5 mins Auto zero point tracking for drift compensation Power supply: 24 vdc Ingress protection: ip65 Enclosure: stainless steel (for sensor cell), anti-static epoxy coated metal alloy (for transmitter) Output: linear, proportional 4-20ma Mounting: wall, duct, pipeline Safety integrity level: sil 2 Atex marking: ce 722 ex ii 2g eex d iic t6, ce 722 ex ii 3g eex na iic t6 Optional: lcd display, alarm leds, potential free relay contacts Hazardous area: zone 1, 2 Application: 1.Oil & gas, petrochemical, refinery 2.Battery rooms, ups facility 3.Mobile switching center (msc) of cellular / telecom site 4.Cracking plants 5.Hydrogenation plants 6.Chemicals 7.Cold stores 8.Pharmaceuticals, medicinal formulation
Key Features: 1.Robust design with high repeatability of switching contacts 2.Over pressure protection 3.Short circuit protection 4.Maintenance free due to inductive circuit movement Key Specifications: 1.Measurement range: 0-400 mbar to 0-6 bar 2.Operating temperature: Ambient: 0°C to +70°C 3.Protection class: IP54 per DIN EN 60529 4.Static operating pressure: 16 bar 5.Diaphragm: NBR or Viton 6.Measuring linearity: < 2.0% Full scale 7.Measuring hysteresis: < 1% Full scale 8.Operating voltage: 24 V DC/AC 9.Output signal: (0) 4-20 mA or 0-10 V, linear, proportional 10.Zero adjustment with the dial 11. 1 or 2 adjustable microswitches 12.Pressure chamber: Brass 13.Pressure connection: G 1/8, female thread Applications areas: 1.Water pumps, lube pump monitoring 2.Pump control 3.Pipe water / liquid flow monitoring 4.Air ducts monitoring Industrial areas: 1.HVAC & MEP applications 2.Cement plants 3.Hydro power plants 4.Manufacturing and chemical plants
Key Features: 1.High sensitivity 2.Robust Design, over pressure protected 3.Wear resistant sensor 4.High resistance to corrosion 5.Low hysteresis 6.Large LED Display Key Specifications: 1.Measuring range: 0 ~ 6 mbar to 0 ~ 60 mbar, max static pressure: 32 bar 0 ~ 32 mbar to 0 ~ 320 mbar, max static pressure: 140 bar 0 ~ 130 mbar to 0 ~ 1300 mbar, max static pressure: 140 bar 0 ~ 500 mbar to 0 ~ 5000 mbar, max static pressure: 140 bar 0 ~ 2 bar to 0 ~ 20 bar, max static pressure: 140 bar 2.Linearity: < 0.1 % 3.Hysteresis: < 0.1 % 4.Temperature coefficient: < 0.5 % / 10° C 5.Operating ambient temperature: -10° C to +70° C 6.Operating media temperature: 0° C to +80° C 7.Protection class: IP67 8.Electrical output: 4-20mA 9.Power supply: 24 V DC 10.Pressure connection: 2 x 1/4� NPT 11.Display: analog display with 0 ~ 100% scale. digital display (only with communication module option -K installed) 12.Electrical connections: internal terminal block 13.Material (media contact): Stainless steel 316 L (1.4404) 14.Electronic housing: Aluminum, surface coated 15.Marking / approval: CE mark, complies with EMV specifications EN 50082-1 and EN 50082-2 Application areas: 1.Filter technique 2.Precision measurements in air conditioning conduits 3.Clean room pressure compensation 4.Burner vacuum measurement 5.Circulating air controlling in furnaces Industrial areas: 1.Air conditioning and ventilation systems 2.HVAC and ventilation application 3.Environment monitoring 4.Clean room and laboratory rooms
Key Features: 1.High sensitivity 2.High repeatability of switching points 3.Long service life 4.Robust Design, over pressure protected Key Specifications: 1.Application: flow switch / control â?? Thermal oil DIN 32 727 or hot water Flow 100 2.Measuring range: 0 ~ 250 mbar to 0 ~ 6 bar 3.Nominal pressure: 25 bar 4.Max. static operating pressure: 6 ~ 16 bar 5.Max. pressure load: one sided overpressure protected up to nominal pressure on (+) and (-) side of diaphragm, partial vacuum protected 6.Accuracy: ± 2.5% of full scale 7.Operating ambient temperature: -10° C to +70° C 8.Operating media temperature: +70° C 9.Protection class: IP54 acc. to DIN EN 60529 10.Mounting: Vertical 11.Zero adjustment: located on dial 12.Contact output: 1 or 2 microswitches, 1-channel change-over contacts 13.Pressure connection: Thread G 1/4 female, cutting ring connection for 6,8,10,12 mm diameter tube of brass, zinced steel or chrome nickel steel 14.Measuring system: diaphragm, of reinforced Viton Application areas: 1.Thermal oil flow monitor and control 2.Hot water flow monitoring and control Industrial areas: 1.Building heating system 2.Power plants, boiler application 3.Clean room and laboratory rooms
Key Features: 1.Catalytic bead based Pellistor sensor cell with low flash energy 2. 10-bit microprocessor control unit 3.Non-intrusive one man calibration via hall effect switches 4.ATEX certified explosion proof / flameproof, suitable for Zone 1, 2 gas explosion installation 5.Linear, proportional analog industry standard current output 6.Continuous system self-diagnosis with watch dog 7.Flashback arrestor with sintered filter 8.Auto Zero point tracking to zero point compensation 9.SIL 2 HW TUV certified 10.RS485 serial interface with Modbus RTU communication (optional) 11. 1 or 3 relay output module (optional) 12.System and alarm LED indicators (optional) 13.Modbus RTU communication over RS485 serial interface
Key Features: 1.Catalytic bead based Pellistor sensor cell with low flash energy 2. 10-bit microprocessor control unit 3.Non-intrusive one man calibration via hall effect switches 4.ATEX certified explosion proof / flameproof, suitable for Zone 1, 2 gas explosion installation 5.Linear, proportional analog industry standard current output 6.Continuous system self-diagnosis with watch dog 7.Flashback arrestor with sintered filter 8.Auto Zero point tracking to zero point compensation 9.SIL 2 HW TUV certified 10.RS485 serial interface with Modbus RTU communication (optional) 11. 1 or 3 relay output module (optional) 12.System and alarm LED indicators (optional) 13.Modbus RTU communication over RS485 serial interface Technical Specifications: 1.Measuring Parameters: LEL or flammable concentration of ammonia gas 2.Sensor Technology: Catalytic bead based pellistor sensor cell 3.Measuring range: 0 ~ 100 % LEL ( 0 ~ 15% v/v @ STP) 4.Response time (t90): < 30 sec 5.Control unit: 10 bit microprocessor based 6.Warm up time: < 5 mins 7.Auto zero point tracking for drift compensation 8.Power supply: 24 VDC 9.Ingress protection: IP65 10.Enclosure: Stainless steel (for sensor cell), anti-static epoxy coated metal alloy (for transmitter) 11.Output: linear, proportional 4-20mA 12.Mounting: wall, duct, pipeline 13.Safety integrity level: SIL 2 14.ATEX marking: 11.CE 722 Ex II 2G EEx d IIC T6 12.CE 722 Ex II 3G EEx nA IIC T6 13.Optional: LCD Display, alarm LEDs, potential free relay contacts 14.Hazardous area: Zone 1, 2
Key Features: 1.Explosion proof ATEX certification with CE Ex II 3 G c EEx nA IIC T4 for DE38###R and CE Ex II 3 D c IP65 T125 for DE38###S 2.Robust design with high repeatability 3.Over pressure protection 4.Wear free non-contact LVDT sensing element, thus no maintenance 5.Signal output with possibility of various characteristic curve 6.Characteristic conversion of output via 3?¦.30 entries table 7.Complete set-up of all parameters and print out by using optional PC programming interface EU03 8.Measuring range: 0-400 mbar to 0-1600 bar 9.Operating temperature: Ambient: -10°C to +70°C; Media:-10°C to +70°C 10.Protection class: IP65 per DIN EN 60529 11.Output: 0/4-20mA, 0-10 VDC 12.Display: 3 ½ digit LCD Applications areas: 1.Monitoring of compressors, filters and vacuum systems 2.Measurement of differential pressure between supply and return fuel lines in heating & 3.cooling systems (Chillers) 4.Flow measurement ?? lubricants, oil, hydrocarbons, water, gases 5.Control pressure ?? air, gases, oil, water, lubricants 6.Level measurement- tank, container of lubricants, oils, water, liquids etc Industrial areas: 1.Cement plants 2.Nuclear plants, coal or gas fired power plants 3.hydro power plants 4.Manufacturing and chemical plants
Solar Water Heater, Solar Lights, Solar Pump, RO Systems, LED Lights, Solar Power Plant, Table Top Scale, Platform Scale, Bench Top Scale, Heavy Platform Scale, Price Computing Scale, Home cum Personal Scale, Jewellery Scale, Digital and Electronic Weighing Scales, laboratory balances, industrial scales and Retail weighing machines.
GSM SCALE (Electronic Weighing Balance) Model No. :EK01 Capacity : 600gm Least Count : 0.01gm 10x10x8inch, weight:5kgs
VGOTECH CROCKMETER – MANUAL Its used to determine the Color Fastness against rubbing (Dry/Wet). Equipped with revolution counter Accessories: • Finger clip - 2pcs. • AATCC Crocking Square : 100pcs 2x.5x1ft, weight-14kgs