24Watt 12V-2Amp Power Supply
36Watt 12V-3Amp Power Supply
60Watt 12V-5Amp Power Supply
60Watt 12V-5Amp With Battery Backup Power Supply
84Watt 12V-7Amp Power Supply
3 Digit , 7 Segment LED Display Voltage input
4 Digit , 7 Segment LED Display Input 1Ã?? 2 Wire, Voltage and Current input Primary CT Selection up to 50 Amps
Voltage and Current input CT Selectable up to 4000/5 1 Relay for Set KW
2 in 1 meters measure average values of DC Voltage or DC Current. Any two different parameters can be measured in one case with this meter. It is housed in UL 94 V-0 approved polycarbonate case and can be mounted in Mosaic mounting (cascading).
2in1 meters measure two different ranges of frequencies in the range of 45 to 450Hz. For maximum accuracy, the essential measuring range is obtained by suppressing unwanted frequency span. The meter is housed in UL94V-0 approved polycarbonate case and can be mounted in Mosaic mounting.
Analog Meters measure AC/DC Voltage or Current and frequency. These meters are installed on 35mm Din rail, the mounting width is 45mm and it is housed in UL 94 V-0 approved polycarbonate case and can be mounted in Mosaic mounting (cascading).
ML14xx is Multiload Monitor with 12 single phase load or 4 three phase load option. It measures important electrical parameters of multiple loads simultaneously in a single unit, eliminating the need and cost of multiple panel meters. It provides quick, easy and error free current connections with plug and play connectors. It measures real time electrical parameters like Active / Reactive / Apparent energy and power, current, THD, demand, max demand for each load. The instrument has 4 configurable relay outputs, which can be used for Limit / Pulse / Residual Current / 3Phase Load Health Monitoring / Tariff / RTC / Timer tripping or alarms. This instrument communicates with either MODBUS or Ethernet connection
Input Voltage240 V: 415 V Input Phase: 3 No Input Frequency: 60 Hz Output Open Circuit Voltage: 89 V Welding Current Range: 20- 500Amp
Product: DD28 MECHANICAL kWH METER Specifications: Model Number: DD28 Accuracy: Class 2.0 Rated Voltage: 220 Volt Rated Current: 10(30-40)Amp Starting Current: 0.5%Ib Rated Frequency: 50 Hz Constant: 600 rev/kWH Power Loss( Under no current): 2W Meter Base: Black Clock Steel Meter Main Cover: Non Transparent( Black Cover) Meter Terminal: Short or Extended Meter Terminal Material: Copper Voltage Coil Material: Copper Current Coil Material: Copper Wire Protection: The Voltage and current coil connecting wire must be insulated with a cover on it Magnet: Big Size Magnet suitable for 30 A to balance the rotation of the wheel. Size and Dia. of Voltage and Current Coil: As per IEC design to bear 30 Amp continuous current Meter Terminal Size: As per IEC norms with continuous current bearing capacity of 30 Ampere Meter Register: 5 Digits ( 4 Integer , 1 Decimal) Meter Bearing: Jewell Quality: Excellent Serial Number: Each DD 28 must have serial number on its name plate Design Standard: GB/T15283-2008 & IEC 521
Accumax offers water metering solutions based on proven technology of Electromagnetic and represent the next generation of smart metering.Accumax delivers solutions in all shapes and sizes. From individual meters and remote reading systems to fully automated service solutions.The meter is true volume measuring meter.
Model EMF-50-PFA-SS316L-MS-150-NO-1-0-0-1-220V Accumax offers water metering solutions based on proven technology of Electromagnetic and represent the next generation of smart metering.Accumax delivers solutions in all shapes and sizes. From individual meters and remote reading systems to fully automated service solutions.The meter is true volume measuring meter. The measurement is independent of viscosity, Density, Dissolved/Undissolved solids, pressure or temperature of the flowing liquid as long as it maintains certain minimum conductivity. Various types of Liner & Electrode are used as per application requirements. Empty pipe detection is also provided.Accumax has in-house R&D centre & calibration setup as per industries standards.Principal of Operation:The Accumax Electromagnetic Flow-meter work on FARADAYs LAW OF ELECTROMAGNETIC INDUCTION. Hence the meter detects flow based on velocity of conductive liquid. Thus the meter are Calibrated in terms of volumetric flow rate from it.Advantages: â?¢ Rugged, Robust, Construction withstanding to IP67.â?¢ No pressure Drop due to full bore constructionâ?¢ Maintenance free construction because of no moving parts.â?¢ Long lasting PTFE/PFA lining maximize life of meter.â?¢ Customized designs are also available as per requirement. Applications:Accumax Electromagnetic Flow-meters are used to measure various types of liquids which can be found in various industrial processes like as Acidic chemical, west water,
Working Principle: This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field. Technical Detail: Nominal Dia (mm) : 25 to 300 NB Material of Construction : MS, SS 304, SS 316 & SS 316L Electrode Material : SS 316, SS 316L, Hastelloy c, & Tantalum Process Pressure : Max. 25 kg/cm2 Process Temperature : Max. 150C Flow Tube Material : SS 316 End Connection : Flange/Wafer Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum Accuracy : ± 1% FSD Optional: ±0.5% FSD. Repeatability : 0.3% Display : 2 Line Alfa Numeric LCD Display Version : Integral /Remote Display Unit : Standard Unit in M3, Litre Power Supply : 230 VAC, 110 VAC & 24 VDC Output : Std. 4 20 mA Protection Class for Sensor : IP 65Protection Class for Transmitter : IP 65 Cable Length for Remote : 10 meters
Gas Generators Common features are gas generator sets: Environment friendly Low noise level Greater load bearing capacity Proven reliability and durability Nation-wide service network Unmatched warranty: 2 years/5000 hours Single window after-sale support round the clock Extended oil change period (1000 hrs) Lower operating cost Application: Generators are used in IT & Telecommunication Companies, Industrial, Agricultural, Infrastructure, Electricity Board etc.
Servo voltage stabilizer (3 kva-1000 kva, 1 phase, 3phase), isolation transformer, neutral transformer, automatic phase corrector, variacs (variable auto transformer), power factor.
Transformers, CTS, PTS, servo voltage stabilizers, CT-pt combined units.