250KW Wind turbines.
Servo stabilizer.
Technical Specification Chart: Parameter 1 - Phase 2 - Phase 3 - Phase Unbalanced Air Cooled 3 - Phase Balanced Oil Cooled 3 - Phase Unbalanced Oil Cooled Energy Conserved Lighting Load Centralized Stabilizer for offices & residence Rating (KVA) 1 - 20 0.5 - 20 3 - 100 3 - 200 3 - 250 3 - 500 3 - 500 I/P Voltage range (V) 170 - 270 195 - 265 340 - 480 240 - 480 340 - 480 360 - 460 310 - 480 340 - 460 360 - 460 340 - 480 360 - 460 310 - 480 340 - 480 360 - 460 310 - 480 340 - 480 360 - 460 O/P Voltage (normal) 230 V 415 V 415 V 415 V 415 V 208 V LN 220 V / 230 V LN Alternate O/P setting 220 V / 240 V 380 V / 400 LL 220 V LN 220 V / 230 V LN O/P V regulation ± 1% of nominal output voltage O/P V Indications Digital voltmeter, accuracy 1% of FS ± 1 digit LED Indications Front panel LED Indicators, Input ON, output ON, Input high / Low, output High / Low trip Under over voltage trip Electronic cutoff circuit with graded time delay set @ + 5% / -10% of nominal voltage Over Load cut off Electronic cutoff circuit with graded time delay set @ 110% of rated full load current Short circuit protection HRC fuse / MCB at input Single phasing prevention Not applicable Provide Individual phase cutoff only Service bypass Not provided Provide upto 100 Kva. 3 phase Individual phase bypass provided up to 50 kVA 3-ph Resetting mode Automatic restart with time delay mode of 15 sec. (optional).
TECHNICAL SPECIFICATION OF ONLINE UPS / INVERTER DESCRIPTION (SINGLE PHASE)/MODEL 3-PHASE(3IN-1OUT) 3-PHASE(3IN-3OUT) MAINS MODE 1KVA 2KVA 3KVA 5KVA 7.5KVA 10KVA 7.5KVA 10KVA 15KVA 20KVA 10KVA 15KVA 20KVA --- 100KVA INVERTER MODE Output Wave Form Sine wave Nominal Battery Voltage 24V DC 48VDC 180 VDC 192 VDC 360 VDC Output Power Factor 0.8 MAX. NO LOAD BATT. CURRENT 1.1 ± 0.2A Total Harmonic Distortion < 3% NO LOAD O/P VOLTAGE(L-N) 220 ±1% 230 VAC ±1% NO LOAD O/P VOLTAGE (L-L) N/A N/A N/A 410 ±1% O/P FREQUENCY 50 ± 0.5Hz FULL LOAD O/P VOLTAGE (N-L) 220 VAC ±1% 230 VAC ±1% 410 ±1% FULL LOAD O/P VOLTAGE (L-L) N/A N/A 410 ±1% LOW BATTERY INDICATION 10.4 ± 0.2 VDC per Battery ( 12 VDC Battery) LOW BATTERY CUT OFF 10.6 ± 0.2 VDC per Battery ( 12 VDC Battery) MAINS MODE INPUT VOLTAGE RANGE (N-L) 140V-280V 170 to 270 ± 5 VAC INPUT VOLTAGE RANGE (L-L) N/A 290V to 480 ± 5 VAC INPUT FREQUENCY RANGE 40Hz to 55Hz INPUT POWER FACTOR 0.9 0.9 N/A CHARGING CURRENT 5A to 10A 1.5 to 8A ± 1A BOOST CHARGING VOLTAGE 13.9 ± 0.2 VDC per Battery ( 12 VDC Battery) PROTECTIONS PROTECTIONS OUTPUT NOT OK, BATTERY VOLTAGE LOW , OVER LOAD BATTERY OVER CHARGE, OVER TEMPERATURE, SHORT CIRCUIT, MAINS MCB TRIPS DISPLAYS DISPLAYS WELCOME MESSEGE, CAPACITY, OUTPUT VOLTAGE, OUTPUT FREQUENCY. LOAD PERCENTAGE INPUT VOLTAGE and FREQUENCY, LOAD PERCENTAGE, BATTERY CHARGING,BATTERY VOLTAGE, ALL PROTECTIONS Environmental Parameters Operating Temperature 0 Deg – 45 Deg Acoustic Noise at 1 Mtr. < 45 DB Relative Humidity Max 95% non - Condensing Thermal management Forced FAN Cooling WEIGHT AND DIMENSIONS With Packaging LXWXH in mm 400x420x135 480x420x135 600x500x730 600x500x730 700x500x770 700x500x770 700x500x770 700x500x770 710x500x770 710x500x770 860x630x950 860x630x950 860x630x950 With Out packaging LXWXH in mm 350x320x90 400x320x90 400x350x600 400x350x600 550x350x670 550x350x670 550x350x670 550x350x670 550x350x670 550x350x670 700x460x830 700x460x830 700x460x830 Net Weight 6.5Kg 8.5Kg 54 67 92 107 92 107 106 115 172 115 115 Gross Weight 7.1Kg 9.1Kg 67 73 108 122 108 122 118 122 189 122 122
1) Servo Stabilizers (1ø and 3ø) 1KVA – 1000KVA 2) Online UPS & Domestic Invertors 1KVA – 100 KVA 3) Micro Controller based Stabilizers 1KVA - 1000KVA 4) Isolation Transformers.
International specifications
Model MPS-01,02,04,05 i/p power-415v,+/-10%,2 phase Frequency-50/60hz o/p power: Voltage-95VDC Current-6 Adc(max) 80*90*30mm, 650gms(moulded)
The air vent turbine ventilator operates by utilizing the velocity energy of the wind to induce airflow by centrifugal action. The centrifugal force caused by the spinning vanes creates a region of low-pressure area, which draws air out through the air vent turbine ventilator. Air drawn out by the ATCO air vent turbine ventilator is continuously replaces by fresh air from the outside. The slightest breeze will cause the ATCO air vent turbine ventilator to spin and even after the breeze has stopped, the flywheel effect of the rotor cage will use its stored energy to continuously remove air giving rise to ventilation. Suction is maintained even at low wind velocities.
Technical Specification Chart Parameter 1 - Phase 2 - Phase 3 - Phase Unbalanced Air Cooled 3 - Phase Balanced Oil Cooled 3 - Phase Unbalanced Oil Cooled Energy Conserved Lighting Load Centralized Stabilizer for offices & residence Rating (KVA) 1 - 20 0.5 - 20 3 - 100 3 - 200 3 - 250 3 - 500 3 - 500 I/P Voltage range (V) 170 - 270 195 - 265 340 - 480 240 - 480 340 - 480 360 - 460 310 - 480 340 - 460 360 - 460 340 - 480 360 - 460 310 - 480 340 - 480 360 - 460 310 - 480 340 - 480 360 - 460 O/P Voltage(normal) 230 V 415 V 415 V 415 V 415 V 208 V LN 220 V / 230 V LN Alternate O/P setting 220 V / 240 V 380 V / 400 LL 220 V LN 220 V / 230 V LN O/P V regulation ¦ 1% of nominal output voltage O/P V Indications Digital voltmeter, accuracy 1% of FS ¦ 1 digit LED Indications Front panel LED Indicators, Input ON, output ON, Input high / Low, output High / Low trip Under over voltage trip Electronic cutoff circuit with graded time delay set @ + 5% / -10% of nominal voltage Over Load cut off Electronic cutoff circuit with graded time delay set @ 110% of rated full load current Short circuit protection HRC fuse / MCB at input Single phasing prevention Not applicable Provide Individual phase cut off only Service bypass Not provided Provide upto 100 Kva. 3 phase Individual phase bypass provided upto 50 kVA 3-ph Resetting mode Automatic restart with time delay mode of 15 sec. (optional)
Power : 400w , minimum wind speed : 3m/s , battery:12v, 150ah , inverter : 1kva
State of the art technology for pure sine wave output with constant voltage and frequency Dsp technology Smps charger with flc Long back up hours with high performace Short circuit protection Led display (mains on, inverter on , mains fuse blown , battery low , over load , short circuit ) Over load protection High/low voltage protection
Pure sine wave output with constant voltage and frequency Digital signal controller based pwm technology using mosfet Longer battery life by intelligent multi stage battery charging save electricity by efficient charging Normal/ups selection to run computer . Led display (mains on, inverter on , mains fuse blown , battery low , over load , short circuit ) Over load protection High/low voltage protection
10 kva to 3000 kva capacity, 3 - phase, 50 hz. For different industrial applications. Input voltage range : 300 to 500 volts or as per Customers requirement Output voltage : 380/ 400/415 + 1% Depen upon caapcity
From 1 kva to 800 kva 1 kva to 5 kva is single in and single out from 7.5 kva to 40 kva 3 in , single out and from 60 kva to 800kva it is 3 in , 3 out . The UPS will be packed with standards wooden pack so that it does not get damaged in transportation
600watts, 6-8 mile seconds transfer time,
Based up on the customer requirement based up on the application
Standard : Certified Company with IS-9815 & ISO 9001-2000 Frequency : 45Hz - 50 Hz AC Power Factor: Suitable for All Input: As Above Output : As Above Cooling : Air Cooled Type : Indoor Type Technology : Microcontroller and Buck & Boost;DimmerType Load: Unbalanced Construction: MS Sheet Body, Power Coated, Low Noisy Wave Form Distortion : Nil Correction Speed : 20-40V/sec Response Time : 10 m/sec Correction Method : Step less correction using Dimmer Control Circuit : Fully Microprocessor based circuit Efficiency : Better than 98% Duty Cycle : 100% Operation : Auto/Manual Load Loss : Less than 1 % Operating : -15 ¦C to 50 ¦C Servicing & Maintenance : Easley can be do by any technical known Person And from company side 24 hrs/ 7 Days Components Available : Easley available in market or in company .
Dinesh micro waves and electronics is one of the worldwide leading manufacturers of power conversion devices, including standard- and custom ac/dc power supplies as well as dc/dc converters ranging from 1, 5 to 1000 watts. Dinesh microwaves and electronics manages customer needs and monitors the latest trends regarding power for a multitude of applications in the areas of industrial machines & appliances, medical equipment, broadcast systems, military devices, laboratory appliances, test- and laboratory equipment, automotive industry, aviation systems, maritime equipment......And many more. A team of dedicated engineers in our headquarters designs power factor corrected switch-mode power supplies using the latest state-of-the-art components. This ensures the delivery of sophisticated, highly efficient and reliable switching power supplies -- open frame switchers, modular, open, and encapsulated dc/dc converters -- which all help to contribute to the very best performance and benefits for our worldwide base of satisfied customers. Products We offers more than 1500 different standard power conversion products like switch mode power supplies, switching power supplies, alternating current power supplies, power factor corrected ac/dc switchers, high reliability and efficiency power supplies, ac/dc power supplies, dc/dc convertors, dc/dc modules, open frame power supplies, din û rail mountable power supplies, custom design power supplies, single phase power supplies, three phase power supplies. 1. Ac to dc power supplies starts from 5 watts to 2500 watts and providing up to 20 channels. 2. Dc to dc convertors starts from 2 watts to 1000 watts and providing up to 20 channels.
12v 7 ah battery sealed maintenence free. 100 nos
Ups system ideal for computers, computer (edp)deptt. With bitcare avr (automatic voltage regulator)range from 1 kva to 100 kva. The best quality products. (specifications differ from product capacities & utility) 2pcs in one packaging for 1kva to 2.5 kva, Single pc packing from 3 kva onwards.