BRAND :L&T MCCB DU/DY With Thermal - Magnetic Release DU MCCB Range [8536] 3 Pole / 4 Pole MCCBs , 2 Pole / 3 Pole / 4 Pole MCCBs , DU250C/DU250/DU400N MCCBs DTH With Thermal - Magnetic Release
BRAND : SCHNEIDER MCB 6A - 32A Single Pole Schneider Miniature Circuit Breaker. Product Specification No.of poles 1-4 Pole Rated current 6 to 63 A Voltage 240-415 V Breaking Capacity 10 kA Frequency 50 Hz Curve Type B and C tripping curves Brand Schneider
ABB MCB System pro M compact S200M miniature circuit breakers are current limiting. Theyhave two different tripping mechanisms, the delayed thermal tripping mechanism foroverload protection and the electromechanic tripping mechanism for short circuitprotection. They are available in different characteristics (B,C,D,K,Z), configurations(1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 10 kA at 230/400 V AC) and ratedcurrents (up to 63A). All MCBs of the product range S200M comply with IEC/EN 60898-1 and IEC/EN 609 47-2, allowing the use for residential, commercial and industrialapplications. Bottom-fitting auxiliary contact can be mounted on S200M to save 50%
Product Description In order to keep pace with never ending demands of the customers, our company is instrumental in presenting an excellent quality assortment of Iron Clad Main Switch. Features: ICTP / ICDPSwitch Fuses are available from 16 Amp. to 63 Amp. All contacts are made from electrolytic Copper and Extruded Brass for high conductivity â??Fuse enclosures are made of best - graded Grey Cast Iron. Quick Make & Quick Brake Mechanism is provided for best performance Units are Weather Proof and Dust Protected. Provision of detachable rubber glands for Cable Entry/Exit Fully shrouded live part Cable termination suitable for accommodating aluminum & copper conductors.
INDICATING LAMP - SIEMENS , ABB , SCHNEIDER , JIGO , TEKNIC Product Specification : Usage/Application INDUSTRIAL Power 10A Lighting Color red,yellow,green,blue,white Body Material pvc Lighting Type LED Brand : ALL Protection Grade IP55 Service Life 50000Hrs Voltage Range 12/24/110/220/440V Minimum Order Quantity 10 Piece Product Description LED Indicating Lamp 16mm-24/110/220 AC/DC
CI Flanged Globe Valve WCB Flanged Globe Valve Forged Steel Globe Valve SS Flanged Globe Valve Stainless Steel Globe Valve Providing you the best range of CI Flanged Globe Valve, WCB Flanged Globe Valve, Forged Steel Globe Valve, SS Flanged Globe Valve, Stainless Steel Globe Valve and Globe Valves with effective & timely delivery.
DEIF GENSET CONTROLLER Automatic Genset Controller AGC-4 Mk II The automatic genset controller AGC-4 MK II can be used as a single genset controller. Also, several AGCs can be connected in a complete power management system for synchronising projects, islanded or paralleled to the mains. The generator controller is ideal for mission-critical applications such as hospitals and data centres, and it is capable of delivering backup power in only six seconds.
GE TRANSFORMER PROTECTION RELAY MODEL :- MUITILIN T60-N11-AKH-F8L-H6N-M8L-P6P U6P-W6;
'ALSTOM' Protection Relay MODEL NO:- P64392AE6M0060M;
Ge Motor Management Relay MODEL NO: 469 MOTOR MANAGEMENT RELAY
'ALSTOM' Protection Relay MODEL NO:- P94VP16A7C0540A; Advanced Transformer Protection, Control and Condition Monitoring Transformers are high capital cost assets in electrical power systems. Internal faults are a risk for all transformers, with short-circuits dissipating the highest localised energy. Unless cleared quickly, the possibility of rewinding will diminish and core damage may become irreparable.The MiCOM Agile P642, P643 and P645 address all these issues - preserving service life and offering fast protection for transformer faults. A transient bias technique has been included, enhancing relay stability and CT requirements. CT saturation and no gap detection techniques have been included to improve the low set differential element operating time during CT saturation where the second harmonic blocking might be asserted. An external fault detection algorithm has been incorporated to prevent the CT saturation and no gap detection from affecting the second harmonic blocking .
GE TRANSFORMER PROTECTION RELAY The T60 Transformer Protection System is part of the Universal Relay (UR) series of products. It is a microprocessor-based relay for protection of small, medium, and large three-phase power transformers. The relay can be configured for a maximum of six three-phase current inputs and six ground current inputs, and can satisfy applications with transformer windings connected between two breakers, such as in a ring bus or in breaker-and-a-half configurations. The T60 performs magnitude and phase shift compensation internally, eliminating requirements for external CT connections and auxiliary CTs.
OMRON ROTARY ENCODER Omron Absolute Rotary Encoder Absolute Encoders output the rotational angle using an absolute code. The rotational position can be detected by reading the code. This eliminates the need to return to the origin at startup
ALSTOM Reverse Power Relay CCUM 21 High Res GBCCUM21PF101A DEFINITE TIME REVERSE POWER RELAY Technical Specifications Model No : CCUM21PF101A CCUM21 AUX. CURRENT OR VOLTAGE - 24V DC C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH MTA PHASE-CHAR ANGLE - 30 DEGREES TIME DELAY P/U OR D/O - 0.5 - 5 SECS. V.T/P.T SECONDARY - 110V AC External Resistor Name Plate RFH9072-604 RZF9151-601 Outline Diagram MFJ013 Wiring Diagram MPDZ609-01-1
ALSTOM Reverse Power Relay CCUM 21 High Res GBCCUM21PF102A DEFINITE TIME REVERSE POWER RELAY Technical Specifications Model No : CCUM21PF102A CCUM21 AUX. CURRENT OR VOLTAGE - 24V DC C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH MTA PHASE-CHAR ANGLE - 30 DEGREES TIME DELAY P/U OR D/O - 1 - 10 SECS. V.T/P.T SECONDARY - 110V AC External Resistor Name Plate RFH9072-604 RZF9151-601 Outline Diagram MFJ 013 Wiring Diagram MPDZ609-01-1
ALSTOM Reverse Power Relay CCUM 21 High Res GBCCUM21PF103A DEFINITE TIME REVERSE POWER RELAY Technical Specifications Model No : CCUM21PF103A CCUM21 AUX. CURRENT OR VOLTAGE - 24V DC C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH MTA PHASE-CHAR ANGLE - 30 DEGREES TIME DELAY P/U OR D/O - 2.5 - 25 SECS. V.T/P.T SECONDARY - 110V AC External Resistor Name Plate RFH9072-604 RZF9151-601 Outline Diagram MFJ013 Wiring Diagram MPDZ609-01-1
ALSTOM Reverse Power Relay CCUM 21 High Res GBCCUM21PF104A DEFINITE TIME REVERSE POWER RELAY WITH S Technical Specifications Model No : CCUM21PF104A CCUM21 AUX. CURRENT OR VOLTAGE - 24 V DC C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH MTA PHASE-CHAR ANGLE - 30 DEGREES TIME DELAY P/U OR D/O - 6 - 60 SECS V.T/P.T SECONDARY - 110 V AC External Resistor Name Plate RFH9072-604 RZF9151-601 Outline Diagram MFJ013 Wiring Diagram MPDZ609-01-1
ALSTOM Reverse Power Relay CCUM 21 High Res GBCCUM21PF106A DEFINITE TIME REVERSE POWER RELAY RELAY MODEL CCUM21PF106A CCUM21 AUX. CURRENT OR VOLTAGE 24V DC C.T. SECONDARY 5 AMP C.T. CASE SIZE 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) 1 N/O 1 N/C S/R FLAG YES FREQUENCY 50 HZ MOUNTING FLUSH MTA PHASE-CHAR ANGLE 30 DEGREES TIME DELAY P/U OR D/O 0.5 - 5 SECS. V.T/P.T SECONDARY 110V AC NAME PLATE-2 RZF9151-601 NAME PLATE-1 RFH9072-604 OUTLINE DRAWING MFJ013 WIRING DIAGRAM MPDZ609-01-2
ALSTOM Reverse Power Relay CCUM 21 High Res GBCCUM21PF107A DEFINITE TIME REVERSE POWER RELAY MODEL NUMBER CCUM21PF107A CCUM21 AUX. CURRENT OR VOLTAGE 24V DC C.T. SECONDARY 5 AMP C.T. CASE SIZE 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) 1 N/O 1 N/C S/R FLAG YES FREQUENCY 50 HZ MOUNTING FLUSH MTA PHASE-CHAR ANGLE 30 DEGREES TIME DELAY P/U OR D/O 1 - 10 SECS. V.T/P.T SECONDARY 110V AC NAME PLATE-2 RZF9151-601 NAME PLATE-1 RFH9072-604 OUTLINE DRAWING MFJ013 WIRING DIAGRAM MPDZ609-01-2
ALSTOM Reverse Power Relay CCUM 21 High Res GBCCUM21PF111A DEFINITE TIME REVERSE POWER RELAY RELAY MODEL CCUM21PF111A CCUM21 AUX. CURRENT OR VOLTAGE 24V DC C.T. SECONDARY 1 AMP CT. CASE SIZE 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) 2 N/O S/R FLAG YES FREQUENCY 50 HZ MOUNTING FLUSH MTA PHASE-CHAR ANGLE 30 DEGREES TIME DELAY P/U OR D/O 0.5 - 5 SECS. V.T/P.T SECONDARY 110V AC OUTLINE DRAWING MFJ013 NAME PLATE-1 RFH9072-604 NAME PLATE-2 RZF9151-601 WIRING DIAGRAM MPDZ609-01-1