-production ventil plug with six connections provides ease to assembly and heat saving. -Optional Ventil plugs production with 8 perforated connection. -Advanced user control and energy saving for comfortable warming with use of thermostatic valve. -Sub connection possibility that hides installation pipes from wall and floor -Possibility to provide thermostatic ventil and thermostatic head. -Possibility to produce Ventil plugs as gear -For stock and usage flexibility, assembly by J type fixing brackets (Alternative bracket types for wall-mounting and floor mounting assembly are optional) - The model's Ventil plugs are on bottom-mid, its distance of all height, type and length are constant and it gives advantage for placement. -Central connection model provides cross-link functionality to increase efficiency of radiator. Central connection model allows to change with different measures without removing installation. -Termo VKR ventil plugs are produced as standard and located at right bottom of panels. -TERMO VKL ventil plugs are produced as standard and located at left bottom of panels. -Termo VK ventil plugs are produced as standard and can be use as left and right as location. -Termo VK-M ventil plugs are connected as bottom and mid center.
Smoke and smell prevention with the high efficiency (minimum smell loss & efficiency loss) World-Famous TRION electrostatic filters Emergency stop button, Control panels which have dirt measurement sensors, provide speed control Smell proof high efficient carbon filters with cylindrical cartridges which can be adjustable due to needed flow rate -
Eurovent certified In the range of 0- 100.000 mâ³/h air flow rate High energy efficiency and manufacturing quality Improved air quality Low noise levels Customer satisfaction-oriented, well-educated technical support -
Ceiling type heat recovery units 8 different models In the range of 500-5.000 mâ³/h air flow rate High energy efficiency & air quality User friendly control panel Fast service and technical support Availability of heater with water or electricity Communication with bms (compatible with the automation) -
Our fire damper (bfd-cs) with en 1366-2:1999 eis 120 certification and ce market. E: integrity I:insulation S:smoke leakage 120 â?? value in minutes of eis classification periods (120 minutes resistance). Fä±re damper is a part of fire wall and it must be closed during fire.Fire dampers should have thermal sensors. The damper has special gasket providing tightness between wall and casing, intumescent gasket, 30 mm thick calsium silicate board, high temprature resistant silicone. -
70 kg/m3 density, 20 mm thickness fire rated rockwool is used between the blade walls. Fire dampers are used for the purpose of preventing the fire and smoke from diffusing to other places with air ducts in building ventilation systems. The fusible link mechanism that is presented at the damper provides the blade in the damper to close by driving with the return spring when it reaches at 72°C and prevents the fire from diffusing to other places. Also, it can be controlled with servomotor automation system, as well. The fusible link is fixed to the damper on the face where damper handle is presented in such a way that it can be replaced easily.
Rectangular sound absorbers and Round sound absorbers are used for providing the absorbtion of the sound occuring in air conditioning and ventilation systems, the filling materials inside the splitters are 2 pieces of glasswools that have one surface coated with fiberglass with 50 mm thickness and 70 Class.Rectangular sound absorber whose splitter thickness is 100 mm and 200 mm.Round sound absorber whose splitter thickness is 100 mm and 200 mm.
Air Handling Units with Direct Expansion Coils No need of any chiller and/or hot water boiler Capable of air conditioning with only a VRF outer unit High COP values, Low initial investment costs Easy and fast solutions for small and medium sized facilities
Channel Type Fans Highly efficient rectangle channel type fan In the range of 950-9.500 m³/h air flow rate Metal sheet with the durability of corrosion Low noise levels Ease of installation Speed control -
In a world where precision, performance, and sustainability drive industrial progress, we proudly stand as your premier provider of advanced Water Cooling Systems, more commonly referred to as chillers. With a steadfast commitment to engineering excellence and a vision for a greener tomorrow, we introduce a transformative solution that redefines the landscape of cooling technology.
Heat pump for 5 kW, 6 kW, 9 kW, 12 kW, 14 kW, 17 kW and 18 kW, 24 kW
Smacna, DW 142-143, DIN 24-194 and TSE standards, production in all sizes and thicknesses from 0.50 mm to 1.20 mm, Internal and external Rubber-Acoustic insulation construction, Galvanized and Manufactured from stainless steel, manufactured in harmony with each other, minimum sealing in flanges and corners, full sealing with mastic after production is provided.
Application: RENAULT TRUCKS KERAX (97-) 290 RENAULT TRUCKS PREMIUM (96-) 210 D Core Size: 617 x 461 x 16 mm Without A/C Drier Packaging Size: 78,3x56,4x5,8 cm Gross Weight: 3,7kg
Plastic Grills, Molded (Cast) Grills, CTP Molded square cross-section grills, FRP Molded Grills Composite grills, molded, CTP orthophthalic grills,CTP isophthalic grills,CTP vinyl ester grills ,grills suitable for every sector. CTP Molded Cast Grills, produced by using variety of resins for different chemical conditions. Compared to metal grills, these grills are much lighter and can be easily processed. Due to high resin level, these grills provide an optimum chemical endurance and minimum maintenance. Cast grills; due to their fiber layers, provide flexibility on the use of panels both transverse and longitudinally, while providing high transport resistance. CTP Molded grills; square and rectangle pored are produced in single piece. CTP grills provide perfect traction on greasy, wet and icy surfaces which is ideal for chemical, industrial and maritime industries. CTP (Composite) Heavy Load Grills Grills those are suitable for uses at heavy load construction zones and heavy load machinery zones. For areas where steel grills are insufficient for load and width. Plastic Grill Closed Heavy Load Grill Diamond shaped designed plate, square profile heavy load grill; provide a safe working environment while providing a pleasant look. Resistance of these grills have been tested and proved for use areas such as busy traffic areas, construction zones that contain forklift and heavy construction machineries PULTRUDED GRILLS CTP profiles that have been produced by pultrusion technique – are constructed by the combination of CTP bars. Due to high fiber they contain, these grills have high resistance Pultruded grills are lighter and practical than metal. PULTRUDED PHENOLIC GRILLS Pultruded grills that contain phenolic resin are commonly used in areas where fire safety is important. Incomparable impact resistance, glass reinforcement and UV resistance responds to maximum levels of need. Pultruded phenolic fiberglass grills, meet all levels of requirements in USCG PFM 2-98 Level 2. Tested in independent laboratories. Fire tests done by the ASTM-E-84 Fire Test Standards, show the fire distribution level at 5 and smoke index at 5. Phenolic resin grills are certified accordingly to USCB rules, and Level 2 qualification of ships, tankers and oil refineries. Fire Proof Phenolic resin Grills Certifications: Rain Water Grill 570x570mm Medium grill interval, diagonal to the road 34,5 Kg 180° openable cover 485x485mm Medium grill interval, diagonal to the road 22,5 Kg 180° openable cover 640x345mm Medium grill interval, diagonal to the road 22,5 Kg 180° openable cover
We bend the tubes and produce tube assemblies. Export packing.
Product Identification, Model and Performance Spcifications Radial produced fan types have different models and shapes which in operation conditions and capasities between 100m3/h 150000 m3/h. Models Have rare bladed, back inclined radial fans (TRHD) Have dense bladed radial fans (TRV and TADH) Also each type of fan can be produced tandem and used multifan, so same kind of two or moreover fans should operate with one motor. When for this kind of fans are used fan selection table, consider that theused fan number is "n", then the pressure value of single fan will be constant so the value which will be read on the curve is the absorbed power is multiply by (n x 1,10) and revolution is multiply by 1,06. Which is the dense bladed type radial TADH fans' rotor blade widht and numbers are more than type of TRV which is dense bladed fans, so that provides more air flowing from the same size fan. The rotor type of rare bladed, back inclined fans (TRHD), completely different than the dense bladed radial fans. Rather sloping of large faced rotor blades on the contery of the dense bladed fans are faced to the back inclined. Place of Origin: Izmir Turkey Brand Name: TKB Makina Model Number: TADH Type: Radial Fan Electric Current Type: Both AC&DC Mounting: Free Standing Blade Material: Stainless Steel , Galvanized St... Air Volume: 3.600 / 140.000 m3/h Speed: 650 / 4.200 dd Certification: CE Power: 3.00 / 75.00 KW Color: Metalic
Copper tube insulated for air conditioning systems. Size from 1/4" - 3/8" - 1/2" - 5/8" - 3/4". Rolls in pallets.
Capacity(kw) Q cooling 7-12n qheating 50n.
Range of self flare fittings Size 1/4" - 3/8" - 1/2"
Model: RA1.5 Max. Weight of Coil: 5000 kg Max. Width of Coil: 1500 mm Inside Diameter of Coil: Between 450 - 650 mm