Hydroelectric Power Plant
Power plants Mid kent generators provide power plants up to 500mw.
Ntm engineering proposes designing gas turbine power plants of small, medium and large capacity. We carry our research, development and engineering projects under the terms of the order of the customer, provide the necessary technical documentation, offer new development, technologies, innovations in energy industry. Ntm engineering combines human talents and modern software technologies to create r&d projects quality and timely. Our high qualified specialists have a large experience in energy industry.
The recovery plant is specially designed to recover CO2 from fermentation processes at breweries. This complete CO2 plant was installed in 2001 and it has nominal CO2 removal capacity of 1000 kg/h. The plant has Siemens S 7 control system where operation is carried our via a large 12 " color screen panel with Windows CE operating system. This is a complete CO2 recovery plant and final delivery scope depends on buyers needs. The plant has been in operation only approx 5 years and is still installed and in very good condition. The carbon dioxide plants was designed by Danish Union Engineering (www.union.dk ) and the delivery includes following main components: - 1 Scrubber for gas flushing - 2 Foam catcher vessels - CO2 collection, inflammable - 2 Mehrer TZW 70 CO2 compressors - 2 Carbon filters - 2 Dehydrators - CO2 Liquefier - CO2 Storage Tank - 2 Cooling compressors GEA Grasso GD-3 for R717 - Air cooled condenser for NH2 compressors - Alarm center for CO2 and NH3 concentration - Station for 40 kg CO2 still tank filling - CO2 pumping station from a truck to the factory - CO2 purification tester - Steam heated evaporator for liquid CO2 Detailed technical information available for serious buyers
Manufacturer pompetravaini italy, made in year 2002. Vacuum pump is two staged rotating pump with externally located, grease lubricated bearings. Pump is liquid ring type designed for water sealed operation. The impeller and shaft are made of stainless steel (aisi 316), cast iron casing and manifold normal steel. The shaft is sealed with double mechanical seal. Pump is provided with connections for service water and draining. Pump includes also anticavitation valve. Pump is dismantled from its base frame but the delivery includes original electric motor eex classified abb hyr 200m lb 4 30 kw, 1476 rpm, year 1995. The equipment will be supplied loose - not as a skid. Technical data:trch 80 - 540/c2/ra Max suction pressure:25 mbar (till 300mbar) Max capacity:540 m3/h (min 400 m3/h) Flanges:80 mm Rotation speed:1500 rpm Power requirement:30 kw at 1500 rpm Year made:2002 Condition:fully operational
Rotary Lube Blower / Vacuum compressor KAESER EB 420 C û 38 m3/min, 53 kPa There are two identical sets of oil-free, 2 lobe rotary blowers, made by Germand Kaeser Kompressoren GmbH in year 2005 with accessories. Manufactures type is Kaeser ED 420 Compact Omega Pluss 53 and accessories include a control cabinet with two inverters and programmable Kaeser Start Control STC 30 unit, totally 6 preliminary intake air filters and 3 final air intake filters with their steel supports. The rotary blower units have removable sound enclose for noise insulation. Operation of the equipment was stopped in year 2007, total running hours approx 7000 and therefore they are in excellent operational condition. In addition, we can offer you service maintenance by the manufacturer at separate cost. This equipment is suitable for demanding dust collection and pneumatic transportation of various products due to oil free operation. For pneumatic transport application some changes in filters and other parts are needed. The rotary lobe has two blower shafts with high efficiency Omega profile in a blower block. The rotary lobe and the block have a very small distance and they are not touching each other's and therefore there is no need for lubrication oil. The rotors are driven by high efficiency electric motor via belt connection and they both are installed on the same base frame. . The inlet and discharge silencers are designed to be effective at all frequencies and are eminently suited to variable speed . Higher rotational blower speeds produce high volumetric efficiencies, which in turn lower discharge temperatures and power consumption. The Compact Range ensures that all serviceable items are accessed from the front panels of enclosures. The preliminary intake air filters are combination of cyclone and bag filter and it removes most of the dust from inlet air. Fine filter is a combination of cyclone and 138 ceramic fine filters which removes fine dust very effectively. Technical Data Manufacture's type: EB 420 Compact Omega plus 53 Manufactured in year: 2005 Suction capacity with max vacuum:38,0 m3/min Power demand max: 40,3 kW Rotor's rotation speed 4120 rpm Max suction vacuum: 0,53 bar (abs.) Discharge pressure: 1,0 bar (abs.) Max pressure increase: 470 mbar Temperature rise max -t: 82 K Electric motor: 45 kW û 50 Hz / 400/690V û 83/48 A Electric motor nominal speed:2965 rpm Protection class: IP 55 Inverters: Mitsubishi FR-F740-01160-EC Case ventilation fan: 370 W û 50 Hz / 230 / 400V Weight blower with the case:1120 kg Blower case main dimensions:1.8 x 1.7 x 1.8 m (K x L x S) Noise level: 99 dB (A) Noise level with the case: 84 dB (A).
Energy Power Plants.
Wind miil.Urban Wind Mill
Waste to Energy plants.
Power plants.
Anaerobic digester or biogas plants cstr digesters turn key.
Power plant, electrical products, telecoms, computer systems and technology goods.Consultancy
Biomass Power Plant, Power Plant.
Steam boilers,hot oil boilers,power plant equipments and revisions, electrostatic and bag chimney filter systems, economizer productions.
Power plant.
Biomass gasification power plant project.
Equipment & spare parts for power plants.
Gas power plant .
Electricity power project, solar energy.Business management services, financial services
Generator sets - power plants, natural gas fueled.