AIR TO WATER HEAT PUMP 6-140 kW CAPACITY POOL HEAT PUMP 6-220 kW CAPACITY GROUNDSOURCE HEAT PUMP 6-60 kW CAPACITY( 8 P�°ECES CASCADE OPTION)
radiators, finned tubes , oil coolers, waste heat boilers
We are manufacturer in Istanbul, Turkey. Our products are respiratory therapy devices; CPAP, AUTOCPAP, BiLEVEL (bipap), BiLEVEL ST, VTAPÃ?(Volume Target Auto Pressure)(AVAPS), ASV (Adaptive Servo Ventilator) with respaps brand. The world health organization released a statement that bilevel, bilevel st, vtap and asv devices are used in the treatment of covid-19. If you need, we can deliver the products to you with the best prices and fast delivery option.
They are compact cooling units used in cold weather, suitable for any environment, not looking for a special team for installation, designed for open and closed environments with plug and play features. The Monoblock series combines the latest cooling technologies with traditional effective solutions. They can work in extreme weather conditions with minimum maintenance requirements. High performance provides low ecological refrigerant charge and low noise emission rate in hermetic cooling circuit. We produce monoblock machines with air-cooled standard, water-cooled and how much cooled.
Cooling capacity Ambient temperature 35¦c , 10500watt ( 9000 kcal/h ) Unit height width lenght Monoblock 190 1350 1800 Air flow (m¦/h) 2040 A/c unit 62, 2 Mounting kit 25 Refrigerant r 134a Power supply 12 vdc - 47 a 24 vdc - 33 a
Any types and specification
Components for chimneys and ventilation systems, made from stainless steel (steel brands aisi 304. 316) and galvanized steel. Diameters for chimneys are in the range 80-1200 mm. The following thickness of chimneys is available: - aisi 304 - 0.5, 0.6, 0.8 and 1.0 mm; - aisi 316 - 0.5, 0.6 and 0.8 mm; - galvanized steel - 0.5 mm. Standard euro pallets, carton or papper, depending on the order.
Type minibus Certification CE Size 15-20 seats Place of origin tr;trprovince201009143 Brand name SAFRAN Model number symphony TS 800 Cooling capacity 9 kw - 7700 kcal/h Refrigerant R134A Compressor cylinder displacement 138 cc Condenser air flow 5700 m3/h Condenser fan pcs 2 pcs axial fan Evaporator air flow 3000 m3/h Evaporator fan pcs 3 pcs blower fan Unit size cond 1250x880x207mm evap 1160x390x160 mm Total weight 55 kg Power input voltage/current 12/24 vdc - 50/25 a.
VENCO energy recovery units (VER), are designed to have high efficiency by using rotary type heat exchangers. The efficiency of VER units is about 80% and this value is higher than the efficiency of VHR units (aluminum plate heat exchangers) at least 25%. By the way, the supply air temperature will be too close to the room temperature and it would not be necessary to use additional heater. Rotary type heat exchangers transfer the humidity as well as the heat. By the way, humidity will be transferred to the supply air from the fresh air in winter. And it is transferred to the exhaust air in the summer time. It helps to keep the humidify level close to the comfort conditions. 7 standard models, with TSEK certification and CE marked in compliance with applicable directives, Indoor air quality with synthetic filters, The design, providing fast and easy installation and maintenance, Low noise level and working on required capacity by using direct driven fan with 3 speeds, The excellent sound and heat isolation, due to fully insulated cabinet, all standard models are available in stock, Please contact us for non-standard capacities.
VENCO Heat Recovery Units (VHR SC) are designed for saving energy and also improving indoor air quality. High Efficiency plug fans are used in these units. VHR SC Units provide the facilities of air-conditioning applications (residential, commercial and industrial areas) by using the plate type heat exchangers that recover the heat. The heat is transferred from warm air to cold air by the exchangers with high conductivity, efficiency and performance. The unit could be equipped with the accessories; Duct Type Electrical Heater, Hot water Coil, Silencer, High Efficiency Filter, By-Pass Kit, Carbon dioxide or Air Quality Sensor. HS Code is 841950000000
Unique air conditioner without external unit. Onle 1 hole through the wall is required. Easy to install, very strong and durabable .
Heat Pump Heat Recovery Ventilation Units with heat pump, designed for saving energy and also improving indoor air quality. VHR DX Units provide heat recovery and well conditioned fresh air by air to air plate type exchangers and heat pump. 30 ¦C fresh air in the summer time and 12¦C fresh air in the winter time can be obtained by usual heat recovery units, but these results are not comfortable. You can obtain 20¦C fresh air in the winter time with high efficiency heat pump. Cartoon Box and Pallet
Venco Duct Type Electrical Heaters are used to heat the fresh air or to reheat the supply air in ventilation systems. Moreover, it is used to increase the supply air temperature with heat recovery units. All electrical Heaters have TSEK and GOST-R certification and CE marked in compliance with applicable directives. Venco duct type electrical heaters are classified as VRE and VCE models. VRE models are rectangular duct type heaters and produced with the dimensions as required. VCE models are circular duct type electrical heaters and produced at a dimension of standard spiral duct diameter. All duct type electrical heaters can be connected to the duct system without any accessory. Cartoon box, pallet
Ambient temperature 35¦c 7558 watt ( 6500 kcal/h ) Dimensions (mm.)unit height width lenght Evaporator 200 350 1090 Condenser 160 800 1230 Weights (kg.)mounting kit 14 A/c unit 46, 7 Other informationsair flow (m¦/h) 1200 Refrigerant r 134a Power supply 12 vdc - 55a
Electrical and heatin are optinal. All our frigorific units are under atp certification. Ambient temperature 30¦c , k
Venco heat recovery units (vhr) are designed for saving energy and also improving indoor air quality. Vhr units provide the facilities of air-conditioning applications (residential, commercial and industrial areas) by using the plate type heat exchangers that recover the heat. The heat is transferred from warm air to cold air by the exchangers with high conductivity, efficiency and performance. The unit could be equipped with the accessories; duct type electrical heater, hot water coil, silencer, high efficiency filter, by-pass kit, carbon dioxide or air quality sensor. Cartoon box and pallet
Specialized for telecommunication sector, roof top, ducted, VRV.
Application area; especially operating theatres, pharmaceutical industry, chemical industry, food production, electronic industry and research laboratories. Sensitive applications in aforementioned application areas require a ventilation system suitable for conditions specified in standards.Gonka laminar flow extract systems reduce microorganism contaminants and particulate concentrations in air to the minimum level in accordance with the standards. Hepa filters which clean filtrated air before going into operating room. Mounting situated in ceiling of the operating theatre in such a way that it should locate over operating table. Stainless steel air distribution box, hepa filters, transparent air distributor (laminarizator) and pendant operating table lighting connection. Easy maintenance and disinfection because of transparent air distributor's being pulled down. Operating theatre lighting system made up of airproof construction. A laminar, vertical air flow from transparent air distributor through operating table prevents turbulent air flow in conventional air systems and offers a high level cleanliness class around the operating table during the operati The system which remove particulates and microbes from operation part due to laminar flow. Special design for operation theatres which require especially high level sterilization in accordance with din 1946. Differential pressure sensors. Easy connection differential pressure sensors and leakage testing. Easy installation to all kinds of ceilings. Depends model
Air handling unit (ahu) 8 different models which provide required humidity and temperature by conditioning air volume in wide ranges. Standard series Application area: business centers, schools, hospitals, factories, hotels and restaurants. 8 different models which provide required humidity and temperature by conditioning air volume in the range of 3000m¦/h and 100.000 m¦/h. The framework which is formed by combination of aluminum frames, which are connected specially, with plastic and aluminum comers. Boards which are made up of double skilled galvanized iron in a standard way. Polyurethane insulated panels, which are 30 mm in thickness, for thermal and acoustic insulation in a standard way. Standard accessories; Filter chambers; chamber design which provides easy mounting and de-mounting in filters and filters with different productivity levels on demand. Heating and cooling coils; seamless cooper tubes. In heating coils, 4 options: warm water, vapor, hot water, electrically heated; in cooling coils, 2 options: chilled water and dx (direct expansion). Dampers; rigid aluminum frame in multi airfoil structure which is the least resistant against airflow. Rubber gaskets which reduce air leakage through blades to the minimum level. Fans; statically and dynamically balanced aspirators and ventilators in double inlet belt driven centrifugal type. Forward curved fans in systems with low, medium and high duct pressures, . Optional accessories; Gonka vapor humidifier, standard vapor cylinder, immersion electrodes, stainless vapor distributor and microprocessor control unit. Mufflers which are made up of coulisses to provide required sound holding capacity. Plate heat exchanger or heat recovery wheel for recovery of the heat emitted with exhaust air. Electrical board. Frequency converter Depends on the size, model and chambers
Gonka packaged hygienic air conditioning units have been designed for meeting the special requirements of clean rooms Application area; gonka packaged hygienic air conditioning units have been designed for meeting the special requirements of modern operating theatres, clean rooms in pharmacy, agriculture, food and aeronautics industries. Highly efficient filtration of supply and extract air. Maximum function control: room temperature and relative humidity control throughout the year. Meeting fresh air that surgical operations require Quiet and non-vibrating operation that operating theatres require. An independent system which is under direct control of authorized health staff. Pressure control in aseptic and septic surgical operations. Continuous control of room temperature and humidity. Quiet and non-vibrating operation. Replacing the old installation in available places and generally, because their sizes are small, occupying less room than any time before, however available air canal and water installation could be, easy erection in any type of health institutions. Depends model