he CMM-G unit is designed for a three-stage process of changing oil in wind turbine gearboxes (draining old oil, flushing the gearbox and filling it with new oil). The unit allows for quick and efficient servicing of wind turbine oil system. The unit can be used for servicing wind turbines made by many different manufacturers. The CMM-G can also heat clean oil.
Copper millberry scrap lead batteries for recycling Liquid mercury Aluminium scrap
This DC to AC inverter is designed for the backlight of 6.4-15.1" LCD Panel with single CCFL lamp Input voltage: 12VDC Kick-off Voltage: min1500 Lamp Voltage: 500V Output Connector Mode: SM02B/ SM02 (8.0)*2 Transformer Qty: 2 Output Current: 6mA Output Voltage: 500V Frequency: 40 KHz Dimmer: Yes Dimension : 95.5mm*20mm*4.7mm.
Used 4.5 MW Back Pressure Steam Turbine for sale; Year of Manufacture: 2005 Year Retired : 2012 Condiotion: Excillent Operating Hours: 17.092 Status:Installed on foundation Generator; Apparent Power: 5.625 kVA Active Power: 4500 kW Power Factor: 0.8 Speed: 1.500 rpm Frequency: 50 Hz Steam Turbine; Inlet Flow Most Economical: 2400 kW Inlet Pressure Rated: 44.5 Bar Inlet Temperature: 360 oC Rating Max. Cont.: 4700 kW Rated Speed: 10.043 rpm
Application: PEUGEOT EXPERT Tepee (VF3V_) 2.0 Hdi 07- FIAT SCUDO 2.0 D Multijet 07- CITROEN JUMPY 2.0 HDi 120 07- OE No. 6455.ES Packaging Size: 69,1x48,6x6,9cm Gross Weight: 3,2kg
r control is designed to Optimize the charging cycles for any type of battery, 230v coil single-pole contactor, D.C. Fuse on rectifier output, delta-star stray flux single-phase power transformer Class h; impregnated in autoclave with ecological epoxy resins, with thermocouples For disconnection due to maximum temperature, single-phase rectifier bridge with Silicon diodes, natural cooling, with snubber protection, mains input and d.C. Output Polarized cables, modular installation on galvanized steel base, sheet steel case with Modular panels so as to assure maximum accessibility in case of service, epoxy Powder coating, oven-baked, standard colour: ral 2002 red, new lexan plate with Charging data very easy to understand, equalized recall push button, on - off push Button, option to adjust the charging time from 90 to 210 minutes, option to adjust The threshold voltage from 2.3 to 2.4 v/cell., equalization charge timed, led signaling Charging phases or result, short check of functions and times, option to program The equalized charge automatically, lab-tested electronic circuit conforming to the Directive on electromagnetic compatibility and ce marking, automatic disconnection Of battery charger due to battery disconnection, option: custom-made color, logo and Silk-screen printing, option: assembly of plugs and battery connectors on request.
Icroprocessor control is Designed to optimize the charging cycles for any type of battery, single mains input Fuses, auxiliary transformer suitable for the supply voltage, d.C. Fuse on rectifier output, Delta-star stray flux single-phase power transformer, tenvex copper windings with Double enamel insulation; class h; impregnated in autoclave with ecological epoxy Resins, with thermocouples for disconnection due to maximum temperature, singlephase Rectifier bridge with silicon diodes, natural cooling, with snubber protection, Mains input and d.C. Output polarized cables, modular installation on galvanized Steel base (type a: 20/10, type b :30/10), sheet steel case with modular panels So as to assure maximum accessibility in case of service (type a : 10/10 - 12/10, Type b : 12/10 – 15/10), epoxy powder coating, oven-baked, standard color: ral 2002 red, lab-tested electronic circuit conforming to the directive on electromagnetic Compatibility and ce marking, equalization charge timed, automatic start, automatic Disconnection of battery charger due to battery disconnection, smart charging system According to the discharge level of the battery, short check of functions and times, Option: custom-made colour and custom-made logo and silk-screen printing, final Acceptance test conforming to safety regulations, charging with decreasing current (wa characteristic): 9÷11 h charging time, charging with decreasing current (wo - Wa characteristic): 7÷8 h charging time, complete with mains and battery cables; Assembly of plugs and battery connectors on request.
Ptek nre3 three phase is designed to recharge medium - large capacity traction And start lead-acid batteries, developed using our forty-year experience in the field Of battery chargers and multi-years application of microprocessor control systems D electronic circuit conforming to the Directive on electromagnetic compatibility and ce marking, automatic disconnection Of battery charger due to battery disconnection, equalization charge based on Time, charging with decreasing current (wa characteristic):9÷11 h charging time, Transformer thermal protection, modular installation on galvanized steel base, sheet Steel case with modular panels, epoxy powder coating, oven-baked, standard color: Ral 5003 blue, option: custom-made color, logo and silk-screen printing, mains Input and d.C. Output polarized cables, complete with mains and battery cables; Assembly of plugs and battery connectors on request. “wa” characteristic (din 41774): Charge at decreasing current with intervention of adjustable final Charge from 2.35 to 2.40 v/cell., final charge with timed control 9h / 11h, fixed charging time (equalization charge excluded), equalization Charge (week-end charge). It will start after 55’ from charge end, Duration of equalized charging phase: each hour 5’ (repeated for 48 Hours), calculation to determine the size of suitable battery charge: 16a for every 100 ah of the battery (e.G. 500 ah battery: 16ax5 = 80a).
Ptek tc3 three phase is designed to recharge medium - large capacity traction and Start lead-acid batteries, developed using our forty-year experience in the field of , three-phase rectifier Bridge with silicon diodes, natural cooling, with snubber protection, mains input and D.C. Output polarized cables, modular installation on galvanized steel base, sheet Steel case with modular panels so as to assure maximum accessibility in case of Service, epoxy powder coating, oven-baked, standard colour: ral 2002 red, new Lexan plate with charging data very easy to understand, equalized recall push Button, on - off push button, option to adjust the charging time from 90 to 210 Minutes, option to adjust the threshold voltage from 2.3 to 2.4 v/cell., equalization Charge timed, led signaling charging phases or result, short check of functions and Times, option to program the equalized charge automatically, lab-tested electronic Circuit conforming to the directive on electromagnetic compatibility and ce marking, Automatic disconnection of battery charger due to battery disconnection, option: Custom-made color, logo and silk-screen printing, option: assembly of plugs and Battery connectors on request. Charge at decreasing current with intervention of the final charge At 2.40 v/cell, final charge with timed control 9h / 11h, fixed Charging time (equalization charge excluded), equalization Charge (week-end charge) to be recalled. It will start after 55’ From charge end, duration of equalized charging phase: each Hour 5’ (repeated for 48 hours), calculation to determine the size Of suitable battery charge: 16a for every 100 ah of the battery (e.G. 500 ah battery: 16ax5 = 80a).
Benefits of hf technology Optimal availability for use and long service life can only be Achieved from motive power batteries when the battery and The charger are perfectly matched. The hf technology permits: Compact wall-mounted designs to save floor space. Significantly higher electrical performances. Shorter recharge time, saving energy and a reduction of The batteries temperature during the cycle, also a strong Reduction of the co2 emissions and lower water consumption, Which helps prolong the life of the batteries. High production Yield. Soft start mode and a customized charge curve on Request. The three phase black hawk is a versatile device, Different charging curve software could be installed for a Specific customized charging profile for any type of battery. Application: Suitable for the cyclic recharge of lead - acid batteries and Floating of sealed gel and / or lead - acid batteries. Air pump available (optional extra) Download data available trough pc/laptop (optional extra)
Benefits of chopper technology Sirius chopper charger is the faster and safer method to recharge Batteries in 2 hours. Thanks to this battery charger you do not need Any dedicated battery room any more, you can avoid all the relative Maintenance problems and the time recovery, and you have less Costs for maintenance and infrastructures and less battery packs. You can also recharge batteries having a great capacity in a very Short time, during the lunch break or when the vehicle is parked Momentarily; so the batteries do not have to be replaced in order to Increase the work time.
Suitable for cyclic recharge of lead – acid Batteries and floating of sealed gel and / Or lead - acid batteries, high frequency Technology, compact design, protected From wrong polarity and short circuit Proof, feeding 110/240v. Ip-66 degree (no ingress of dust; Complete protection against contact - Dust tight, water projected in powerful Jets (12.5 mm nozzle) against the Enclosure from any direction shall have No harmful effects).
Advantages of hf technology: Optimal availability for use and long Service life can only be achieved from Motive power batteries when the battery And the charger are perfectly matched. The hf technology provides: Compact wall-mounted designs to save Floor space. Significantly higher electrical Performances. Shorter recharge time, Saving energy, reduction of the batteries Temperature during the cycle, strong Reduction of the co2 emissions, lower Water consumption, which helps prolong The life of the batteries. High production Yield. Soft start mode, customized Charge curve on request. Black hawk is a Versatile device, different charging curve Software could be installed for a specific Customized charging profile for any type Of battery. Usage: suitable for the cyclic recharge Of lead - acid batteries and floating of Sealed gel and / or lead - acid batteries. Optional air pump available Download data available Trough pc/laptop. 230 vca ± 10%, mono-phase, input frequency 50 – 60 hz, efficiency ~ 90%, Operating temperature from– 20 to + 45 °c, current drawn by the battery 0 A if network electrically bonded, protection against output short-circuit with Fuse, protection against polarity reversal with Fuse, thermal protection semi-conductors, input Protection with fuses and varistors, charge curve Programming and settings at will with default iu Ia, displaying and messages with monochromatic 2x20 lcd display – led, audible alarm device, State charge indicator multicolours, thermal Compensation with optional probe, 2 auxiliary Contacts optional configuration at will (mains Presence, finished charge, control pump, etc…), Ventilation forced air circulation, metallic ontainer With dimensions 490 x 360 x 150 mm, weight 11 kg, protection ip20, in conformity with the Low voltage directive 73/23/cee and the emc Directive 89/336/cee and their successive Amendments.
Over voltages, polarity reversal, anomalies. Error code of any anomaly, inner self ventilation Through forced air, efficiency > 85%, mass-produced Mains leads, input cable, connection to the battery Through anderson-rema power terminals. Nfm Switching battery charger, high frequency technology, Fully controlled by microprocessor. 240v single-phase +- 10%, luminous display for a Easy reading of the charging parameters. Different charging curves in accordance with the kind Of battery and choose among 16 standard curves, Preprogrammed valid for pb-acid, gel. Battery voltage and charge current can be changed Through the button in the front panel. “soft start” mode and display of the charging cycle With led . Electronic protection and/or fuse against short circuits Over voltages, polarity reversal, anomalies. Error code of any anomaly, inner self ventilation Through forced air, efficiency > 85%, mass-produced Mains leads, input cable, connection to the battery Through anderson-rema power terminals. Nfc Switching battery charger, high frequency technology, Fully controlled by microprocessor. 240v single-phase +- 10%, luminous display for a Easy reading of the charging parameters. Different charging curves in accordance with the kind Of battery and choose among 16 standard curves, Preprogrammed valid for pb-acid, gel. Battery voltage and charge current can be changed Through the button in the front panel. “soft start” mode and display of the charging cycle With led . Electronic protection and/or fuse against short circuits Over voltages, polarity reversal, anomalies. Error code of any anomaly, inner self ventilation Through forced air, efficiency > 85%, error code Display missing, mass-produced input network cable, Output cables polarized.
10v and/or 220v as default. Each ptek rvhf battery charger is equipped with external aluminium cover box, Input cable and battery cables (for small one equipped with a fast connection Crocodile). Switching battery charger high frequency technology, feeding 100 ÷ 240v singlephase +- 10%, digital display only for d version, different charging curves selectable For pb-acid, gel, “soft start” mode, electronic protection and/or fuse against short Circuits over voltages, polarity reversal or anomalies, input cable, connection of the Battery included, inner self contained ventilation through forced air, efficiency > 85%, mass-produced mains leads.
Advantages of hf technology: Optimal availability for use and long s Temperature during the cycle, strong Reduction of the co2 emissions, lower Water consumption, which helps prolong The life of the batteries. High production Yield. Soft start mode, customized Charge curve on request. Black hawk is a Versatile device, different charging curve Software could be installed for a specific Customized charging profile for any type Of battery. Usage: suitable for the cyclic recharge Of lead - acid batteries and floating of Sealed gel and / or lead - acid batteries. Optional air pump available Download data available Trough pc/laptop. 400 vca ± 15%, three-phase, input frequency 50 – 60 hz, efficiency ~ 90%, operating Temperature from– 20 to + 45 °c, current drawn by the battery 0 a if network Electrically Bonded, protection against output short-circuit with fuse, protection against polarity Reversal with fuse, thermal protection semi-conductors, input protection with fuses And varistors, charge curve programming and settings at will with default iu ia, Displaying and messages with monochromatic 2x20 lcd display – led, audible alarm Device, state charge indicator multicolours, thermal compensation with optional Probe, 2 auxiliary contacts optional configuration at will (mains presence, finished Charge, control pump, etc…), ventilation forced air circulation, metallic ontainer with Dimensions 490 x 360 x 150 mm, weight 20 kg (air version 23kg - 503x490x153 Mm), protection ip20, in conformity with the low voltage directive 73/23/cee and The emc directive 89/336/cee and their successive amendments.
Ptek nr3 three phase is designed to recharge medium - large capacity traction and Start lead-acid batteries, developed using our forty-year experience in the field of Battery chargers and multi-years application of microprocessor control systems which On, short check of functions and Times, option to program the equalized charge automatically, lab tested electronic Circuit conforming to the directive on electromagnetic compatibility and ce marking, Automatic disconnection of battery charger due to battery disconnection, equalization Charge based on time, charging with decreasing current (wa characteristic): 9÷11 H charging time, transformer thermal protection, modular installation on galvanized Steel base, sheet steel case with modular panels, epoxy powder coating, oven-baked, Standard colour: ral 2004 orange, option: custom-made color, logo and silk-screen Printing, mains input and d.C. Output polarized cables, complete with mains and Battery cables; assembly of plugs and battery connectors on request. “wa” characteristic (din 41774): Charge at decreasing current with intervention of adjustable final Charge from 2.35 to 2.40 v/cell., final charge with timed control 9h / 11h, fixed charging time (equalization charge excluded), equalization Charge (week-end charge) to be recalled. It will start after 55’ from Charge end, duration of equalized charging phase: each hour 5’ (repeated for 48 hours), calculation to determine the size of suitable Battery charge: 16a for every 100 ah of the battery (e.G. 500 ah Battery: 16ax5 = 80a).
The benefits of ptek rchf3 Ripple, it also integrate the input and output protections and Is equipped with an over-temperature control both on the Primary side and the secondary side of the converter. With a wholly programmable control unit, easy-to-use with the User-friendly graphic interface displaying all the parameters, Historical data of the charge cycles executed, alarms, data Plate and all general information concerning the device. The interface also allows setting all the charge parameters, Selecting the charge curves, setting the clock and activating all The optional functions. Ptek rchf is equipped with a monochromatic graphic lcd Display of 64x128 pixels. The control unit can be connect it to a personal computer. An interface software for pc is available permitting a whole Configuration of the ptek rchf, in order to check and monitor All the functions in real time. The software is equipped With a specific tool for the charge curve configuration and Customization. Input voltage: 400 vca ± 15% three-phase, input frequency: 50 – 60 hz, Efficiency: ~ 90%, operating temperature: – 20 to + 50 °c, current drawn by the Battery: 0 a, if network electrically bonded, protection against output short-circuit, Protection against polarity reversal, thermal protection semi-conductors, input Protection, charge curve: programming and settings, displaying and messages with Monochromatic graphic lcd display, thermal compensation with optional probe, Ventilation with forced air circulation, metallic body with these dimensions: 830 x 500 x 500 mm, protection ip20, in conformity with the low voltage directive 73/23/ Cee and the emc and directive 89/336/cee and their successive amendments.
Attery charger due to battery Disconnection, smart charging system according to the discharge level of the battery, Short check of functions and times, option: custom-made colour and custom-made Logo and silk-screen printing, final acceptance test conforming to safety regulations, Charging with decreasing current (wa characteristic): 9÷11 h charging time, charging With decreasing current (wo - wa characteristic): 7÷8 h charging time, complete With mains and battery cables; assembly of plugs and battery connectors on request. Wa (din 41774): Charge at decreasing current with intervention of the Final charge at 2.40 v/cell, final charge with timed Control 9h / 11h, fixed charging time (equalization Charge excluded), equalization charge (week-end Charge) to be recalled. It will start after 55’ from Charge end, duration of equalized charging phase: Each hour 5’ (repeated for 48 hours), calculation to Determine the size of suitable battery charge: 16a For every 100 ah of the battery (e.G. 500 ah battery: 16ax5 = 80a). Wo-wa: Charge at decreasing current with intervention of the Final charge at 2.42 v/cell, final charge with timed Control 7h / 8h, fixed charging time (equalization Charge excluded), equalization charge (week-end
ier output, rectifier bridge with snubber protection, short check of functions and times, option to program the equalized charge automatically, lab tested electronic circuit conforming to the directive on electromagnetic compatibility and CE marking, automatic Start, automatic disconnection of battery charger due to battery disconnection, equalization charge based on time, charging with decreasing current (Wa characteristic): 9÷11 h charging time, transformer thermal protection, modular installation on galvanized steel base (20/10) – (30/10), sheet steel case with modular panels (10/10 - 12/10) - (12/10 – 15/10), epoxy powder coating, oven-baked, standard colour: RAL 2002 red, option: custom-made colour, logo and silk-screen printing, mains input and d.c. output polarized cables, complete with mains and battery cables; assembly of plugs and battery connectors on request. “WA” CHARACTERISTIC (DIN 41774): charge at decreasing current with intervention of the final charge at 2.40 V/cell., final charge with timed control 9h / 11h, fixed charging time (equalization charge excluded), equalization charge (week-end charge) to be recalled. It will start after 55’ from charge end, duration of equalized charging phase: each hour 5’ (repeated for 48 hours), calculation to determine the size of suitable battery charge: 16A for every 100 Ah of the battery (e.g. 500 Ah battery: 16Ax5 = 80A).