Power and energy calibrators, multifunction calibrator, multifunctional portable calibrator, calibrator.
Parameters: - voltage ranges from 1.4 V up to 750 V, - current ranges from 5 mA up to 100 A with a galvanic insulation of outputs, - frequency ranges from 40 Hz up to 1250 Hz, - power generation from 0 W up to 3 x 75 000 W, - voltage and current accuracy 0.05%, - power and energy accuracy 0.8%, - harmonic course generation, - synchronization with supply frequency, - RS-232C, IEEE488 interfaces, - measurement of DC voltage and current up to 10 V and 20 mA, - setting optional parameters: U, I, P, E, cos, t. INMEL 8033 Calibrator is a three-phase electric power and energy calibrator. It generates voltages of equal rms value on three voltage outputs and currents of equal rms value on three current outputs. The voltage on voltage output and the current on current output are shifted between them by set phase angle. Against to the previous model calibrator type INMEL 33, the new device INMEL 8033 one characterize less voltage, current, power and angle generation error, has also wider frequency range of quantity generate and richer program function set. The most important from program functions is the possibility to generate harmonic course. The main distinctive feature of INMEL 33 from INMEL 8033 is digital method measurement generating and stabilization output signals. Application: Checking ang calibration: - Wattmeters, varmeters, - phase meters, - frequency meters, - AC of voltmeters and ammeters, - power factor and phase angle meters, - measuring transducers, - watt-hour meters in single and three-phase system, - power engineering protections.
Parameters: - simulation and measurement: thermocouple signals J, K, T, R, S, B, U, L, E, N, with auto-compensation of terminal temperature, signals in thermocouple and thermostat system, resistance thermometer signals: Pt 100, Pt 500, Pt 1000, Ni 100, Cu 100, resistance signals from 10 up to 5 , voltages and currents in range: -11 V...+11 V and 22 mA...+ 22 mA - accuracy 0.025% - STEP and RAMP function, - led out 24 V terminals, - RS 232C interface, - available in the option for pressure calibration. The INMEL 60 calibrator is destined to check and control systems, industrial automatic control engineering devices such controllers, recorders, meters, etc. This instrument has the possibility to generate and measure signals from ten thermocouples, five thermometer resistances, four voltage ranges, two current ranges, two resistance ranges. Thermoelectric terminals have an internal temperature measurement and for this reason make possible the generation or measurement of thermoelectric signals with the compensation for the given thermocouple. In this working mode, a real thermocouple is added to thermoelectric measuring terminals, and compensation conductors to thermoelectric generating terminals. The calibrator ensures the simultaneous generation of the signal on output terminals and the measurement of the signal on measuring terminals, thanks to this feature the calibrator is suitable to check transducers. The INMEL 60 calibrator enables to check two-wire transducers. the used graphical display contains a lot of information on a screen with a good readability. The display ground-lighting, which can be switched off, is especially useful in conditions of an insufficient lighting. The internal supply from the battery enables the work not only in laboratory conditions but also on the object. The calibrator can also be used to the maintenance and servicing of industrial measuring instruments, systems and electronic equipment. Application: Checking and calibration: - measuring transducers controlled by a voltage or current signal, a thermoelement or resistance thermometer, - two-wire transducers, - temperature meters, - pressure transducers, - manometers, - measuring and control lines.
Technical parameters: - Voltage ranges from 200 V up to 1000 V, - Current ranges from 200 A up to 20 A, - Frequency ranges from 20 Hz up to 100 kHz, - Resistance from 1 up to 19 M, - Voltage accuracy from 35 ppm, - Current accuracy from 150 ppm, - Ample software, - High output load, - RS 232C , IEEE488 interfaces. The INMEL 7000 calibrator is device with very high precision and simultaneously high load, thanks that it pulls ones weight very well with checking modern type as well older types of meters. It is characterized elastic and open systemic structure. We offer varius version of this calibrator from very simple e.g the DC voltage calibrator up to full configuration : DCV, DCI,ACV,ACI and R. Thanks to ergonomic desc and rich internal software the INMEL 7000 calibrator is very handly. In calibrator INMEL 7000 used modern construction solution, in which used new generation of electronics elements of renowned worldwide companies. Thanks that ones received very good metrological parameters, reduced quantity of compnents, and in this way augment the reliability of this calibrator. Application: Checking and calibration: - AC and DC voltmeters, - AC and DC ammeters, - frequency meters, - measuring transducers, - ohmmeters.
Technical parameters: - Voltage ranges 0.2 do 1000 V, - Current ranges od 20 mA do 20 A, - Frequency ranges od 40 Hz do 5000 Hz, - Voltage and current accuracy DC 0.02%, - Voltage and current accuracy AC 0.05%, - Load carrying capacity 40 VA, - Serial interface RS232, USB, Ethernet. The INMEL 1000 calibrator was made on base of modern componenets of microprocessor technologies. Applicated technologies are comparable with technologies used by leading global companies.The INMEL 1000 calibrator characterize oneself the innovative structure of operation in range of output signals and operation of measuring and regulatory loop.For AC course possible is the synchronous operation with the main. This possibility influence on output parameters, reliability, comfort of work, the communication way with user and external devices. The calibrator INMEL 1000 fulfils directives of the European Union within the range safeties and the electromagnetic compatibility:The production of the INMEL 1000 calibrator does not create threats for environment. Application: Checking ang calibration: - AC and DC voltmeters, - AC and DC ammeters, - frequency meters, - measuring transducers.
Parameters: - voltage measure: 0 100mV, 0 10V, - current measure: 0-24 mA, - voltage generation: 0 100 mV, 0 10V, - current generation: 0 24 mA, - voltage accuracy: 0.02% + 2 digits, - current accuracy: 0.015% + 2 digits, - loop power output: 24V Calibrator INMEL 50 integrate generation and measurement function of electric signals, used in automatic industry. The main features of this devices is high accuracy and resolution of generating or measuring signals, friendly operation and large display. Application: Checking and calibration: - measuring transducers, - measuring and control lines, - current loop.