1. Introduction KYN28-12 indoor metalclad withdrawable switchgear is designed to be complete distribution equipment with three-phase A.C. singe busbar and single busbar section system having a rated voltage of 3.6~12kV and rated frequency of 50Hz.The switchgear is mainly employed in receiving and distribution of power energy from the network as well as starting of large-sized HV motors. In addition, the switchgear is provided with controlling, protection and monitoring functions. The switchgear conforms to IEC 298, GB 3906, DL/T404-91 and other standards. The switchgear itself owns five prevention functions such as prevention of misoperation of circuit breakers, prevention of pushing or pulling truck with load, prevention of closing earth switch under voltage, prevention of supplying power when earth switch is at the earth position and prevention of entering the electrical separation zone by accident. The switchgear selects not only VS1 vacuum circuit breakers but also ABB made VD4 vacuum circuit breaders, thus recogninzed as power distribution equipment with excellent performance. 2. Working condition 2.1 altitude: 1000m 2.2 temperature: -10celsius degree ~+40celsius degree 2.3 relative humidity: daily average value 95%, monthly average value 90% 2.4 saturated vapor pressure: daily average value 2.2 10-3MPa, monthly average value 1.8 10-3MPa 2.5 earthquake intensity: less than 8 degree 2.6 protect the product from fire, explosion, earthquake and corrosion atmosphere. 3. Main features: 3.1. the enclosure is completely adopts the aluminum-zinc alloy coated steel sheet, which are machined and bent by machine tool and then bolted; 3.2. all the operations are under the door closing condition 3.3. with high protection category, can prevent intruding of sundries and insects 3.4. simple efficient 5 protection function can prevent operating incorrectly 3.5. the removing compartment of the switchgear may be assembled with VS1(ZN63A) or VD4 vacuum circuit breaker according to customer s demand 3.6. the replacing of VCB is simple and the interchangeability of truck is good. 3.7. the cabinet body can be installed against the wall, so the maintenance can be made in front of the cabinet and the cover area can be reduced too. 3.8. cable compartment has enough room, can connect muti-cable 3.9. high speed earthing switch is used for grounding and loop short circuit 3.10. VCB vault, relay vault and cable vault can add extra heater separately according the demand of customer, in order to avoiding condensation pheromone and corrosion. 3.11. VCB vault and cable compartment can add extra lighting device separately, in order to convenient maintenance. 4. Main technical parameters 4.1 main technical of vacuum switchgear item unit parameter Rated voltage kV 3.6 7.2 12 Rated current A 630 1250 1600 2000 2500 3150 Rated frequency Hz 50 Rated short-time withstand current kA 16 20 25 31.5 40 Rated peak withstand current kA 40 50 63 80 100 Rated power-frequency withstand voltage kV 42/1min Rated lightning impulse withstand voltage kV 75 Rated duration of short circuit S 4 Degree of protection IP4X 4.2main technical parameters of vacuum circuit breaker Item Unit Parameter Rated voltage kV 12 Rated current A 630 1250 1600 2000 2500 3150 Rated short circuit breaking current kA 25 31.5 40 Rated short-time withstand current kA 25 31.5 40 Rated short circuit making current kA 63 80 100 Rated short-time power-frequency withstand voltage kV 42/1min Rated lightning impulse withstand voltage (peak) kV 75 Rated short circuit duration S 4 Closing time (rated voltage) ms 35 t 70 Opening time (rated voltage) ms 20 t 50 Rated breaking times of short circuit times 50 (40kAis 30) Mechanical life times 20000 4.3main technical parameters of operation mechanism Item Unit parameter Rated operation voltage Opening coil V DC220/110 AC220/110 Closing coil Rated operation current Opening coil A (DC/AC)220/110V: 0.9/1.8 Closing coil (DC/AC)220/110V: 1.0/2.0 Power of energy storage motor W 70 Rated voltage of energy storage motor V DC220/110 AC220/110 Energy storage time S 15 5. Structure instruction The basic structure of switchgear panel comprises the panel itself and a removing part (truck). The enclosure and clap-board of the switchgear is bolted with Al-Zn alloy coated steel.Enclosure protection degree of switchgear is IP4X, and the protection degree of every vault is IP2X. 800/1000*1500*2300mm.
“POLYCAB” is an ISO-9001 Co. is one of the leading names in the wire & cable indust.with a track record of over three decades.CPRI/ ERDA tested prod. having lice.for IS 694/1554 (P-1, P-2) 7098 (P-1, P-2), 9857, 2465, 9968, 8783, 8784. “BRIMSON” is an ISO-9001 ,company having licence ISI 694, 1554, 7098 (P-1) that has made a mark for itself in a short period of more then two decade. All due to its commitment to provide a wide variety of Wires and cables. “BRIMPLAST” is also having a ISI Licensed issued by bureau of India standard as per IS:694/IS:1554(PART-1) and we have very sophisticated lab equipped with latest instruments for. testing ultimate strengths of onductors,insulation,steel & shelth in accordance to IS specification. “GI CABLE TRAY” We have all sizes of Perforated & Ladder type in GI/Hot Dip Galvanised/Powder, Coated cable tray. POLYCAB Brimson & Brimplast: PVC/XLPE 1.1 KV Power & Control (SOLID/Stranded) H.R. /FR/ FRLS Cables. Flexible Single Core & Multicore PVC/HR/FR OR FRLS Flexible Cables. Flexible Screened & Instrumentation PVC/FRLS Unarmoured & Armoured Cables. LAN (Cat-5 & Cat-6) Unarmoured & Armoured Cables. Brimplast: Speaker , C.C.T.V. (Camera) ,Co-Axial & Telephone Unarmoured & Armoured Cables. Teflon & Fiber Glass Cable. MDF BOX & CONNECTORS (Dis Connection Type). POLYCAB : Submersible & ELEVATOR Cables. Larsen & Toubro: [L&T] ACB, SDFU, FUSE, MCCB, Changeover, Motor & Soft Starters, Contactors, Relay, Timers, Electronic Meters , MPCB, PANEL METERS, PLC, CAPACITOR. hager: MCB, ELCB & Distribution Boards, 2 Way Changeover , Isolator, Automation & Control Devices. Tripper: ELCB+MCB [Combination]. Salzer: PVC CHANNEL & ROTARY SWITCH GIC: TIMERS & TIME SWITCH YASKAWA: AC Variable Frequency Drives.
Switch gears. Thermopore Packing.
Overview: The RT6103-S Single Phase Energy Meter Test Instrument (Split Type) adopts internationally advanced new-generation digital power source technologt, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The single phase energy meter test instrument comprises of PWM power source, standard digital energy meter,error processor and PC processing software, this energy meter test instrument can test 3 to 60 various watt-hour meters of Grade 0.5 or lower simultaneously, also is an ideal new-generation multi-position energy meter testing instrument. Technical Parameters: 1. Accuracy class: 0.1/0.05. 2. Reference standard energy meter£ºSingle phase wide-measurement range standard energy meter.(Accuracy class:0.1/0.05). Multi-path voltage transformer: Accuracy class:0.01; Rated load per path:10VA. 3. Voltage range:220v(240V option),Output range:0~125%,Resolution:0.01%full range. 4. Current measurement range:0.1~100A(200A option),Output range:0~120%,Resolution:0.0001A(minimum) 5. Phase angle:0~360¡ã,Resolution of phase angle setting:0.01¡ã. 6. Frequency:45Hz~65Hz,Resolution:0.01Hz. 7. Output waveform distortion:Both voltage and current
Overview: The RT6103B Multi-function single phase energy meter test instrument adopts internationally advanced new-generation digital power source technology, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The Multi-function single phase energy meter test instrument comprises of PWM power source, standard digital energy meter, error processor and PC processing software, this energy meter test instrument can test 3 to 60 various watt-hour meters of Grade 0.5 or lower simultaneously, also is an ideal new-generation multi-position energy meter testing instrument. Technical Parameters: 1. Accuracy class: 0.1/0.05 2. Reference standard energy meter£ºSingle phase wide-measurement range standard energy meter(Accuracy class:0.1/0.05), Multi-path voltage transformer: Accuracy class:0.01;Rated load per path:10VA. 3. Voltage range:220v(240V option),Output range:0~125%,Resolution:0.01%full range. 4. Current measurement range:0.1~100A(200A option),Output range:0~120%,Resolution:0.0001A(minimum). 5. Phase angle:0~360¡ã,Resolution of phase angle setting:0.01¡ã. 6. Frequency:45Hz~65Hz,Resolution:0.01Hz. 7. Output waveform distortion: Both voltage and current
Overview: The RT6103F Anti-tamper Single Phase Energy Meter Test Instrument adopts internationally advanced new-generation digital power source technology, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The Multi-function single phase energy meter test instrument comprises of PWM power source, standard digital energy meter, error processor and PC processing software, this energy meter test instrument can test 3 to 60 various watt-hour meters of Grade 0.5 or lower simultaneously, also is an ideal new-generation multi-position energy meter testing instrument. Technical Parameters: 1. Accuracy class: 0.1/0.05 2. Reference standard energy meter£ºSingle phase wide-measurement range standard energy meter.(Accuracy class:0.1/0.05)Multi-path voltage transformer: Accuracy class:0.01; Rated load per path:10VA 3. Voltage range:220v(240V option),Output range:0~125%,Resolution:0.01%full range 4. Current measurement range:0.1~100A(200A option),Output range:0~120%,Resolution:0.0001A(minimum) 5. Phase angle:0~360¡ã,Resolution of phase angle setting:0.01¡ã 6. Frequency:45Hz~65Hz,Resolution:0.01Hz 7. Output waveform distortion: Both voltage and current
Overview: The RT6303-S Three Phase Energy Meter Test Instrument(Split Type) adopts internationally advanced new-generation digital power source technologt,integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way.The Three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis,digital frequency modulation,digital amplitude modulation,digital phase-shifting,pulse width modulation and so on to bring you such important features as high reliability and good load characteristics.Its more humane and intelligent meter calibration software makes it possible for an ordinary,heavy and boring calibration to be carried out more easily and efficiently. Technical Parameters: 1. Accuracy class: 0.1/0.05 2. Reference standard energy meter: Three phase wide-measurement range standard energy meter,Accuracy class:0.1/0.05 3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range,adjustable phase by phase 4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase 5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase 6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz 7. Output waveform distortion:Both voltage and current
Overview: The RT6303B Multi-function Three Phase Energy Meter Test Instrument adopts internationally advanced new-generation digital power source technology, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The Multi-function three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis, digital frequency modulation, digital amplitude modulation, digital phase-shifting, pulse width modulation and so on to bring you such important features as high reliability and good load characteristics. Its more humane and intelligent meter calibration software makes it possible for an ordinary, heavy and boring calibration to be carried out more easily and efficiently. Technical Parameters: 1. Accuracy class: 0.1/0.05 2. Reference standard energy meter: Three phase wide-measurement range standard energy meter, Accuracy class:0.1/0.05 3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range, adjustable phase by phase 4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase 5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase 6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz 7. Output waveform distortion: Both voltage and current
SIVACON 8PV is the most advantage type of Siemens. The Max current is 6300A for MCC.
The AEC1112- Computerized Universal Testing Machine with a maximum load capacity of up to 10, 20, 40, 60, 80, 100 and 200 Ton with the provision of testing various samples of metals and its different alloys for the testing in tensile mode for round and flat specimens as per the national and International standard like ASTM, DIN, ISO, EU and IS standards etc. capacity of up to 10, 20, 40, 60, 80, 100 and 200 Ton.
This easy to use gauge helps you to be certain that air and moisture have been removed from the system. 1.Unique patented thermal conductivity sensor automatically compensates for temperature. 2.Replaceable , cleanable, plug-in sensor handles 450psi positive pressure. 3.Displays 8 different units of vacuum(microns, Torr, Bar, Psi, Kpa, Kg/cm2, mmHg, inHg) 4.Displays down to the equivalent of 10 microns of vacuum 5.12¡¯ coiled sensor cord stretches to 24¡¯ for easy reach, connectivity, and readable of display 6.Operating temperature range: 0¡æ to 50¡æ(32¨H to 122¨H) 7.Low battery indicator 8.Automatic shut-off after 15 minutes 9.Weight:12Oz.(340g) with battery.
Application:used for measuring thickness and corrosion of pressure vessels,chemical equipment,boilers,oil storage tanks,etc.in industries of petroleum,shipbuilding,power station,and machine manufacturing. Model: CM8825FN In built probe(s) Operating principle: magnetic induction/eddy current (F/NF) Measuring range:0-1250um/0-50mil Resolution; 0.1/1 Accuracy: í+1-3%n or í+2.5um Min. measuring area: 6mm Min. sample thickness: 0.3mm Battery indicator: low battery indicator Metric/ imperial: convertible Power supply: 4x1.5V AAA(UM-4)battery Auto power off Operating conditions:0-+45íµ(32¿H-104¿H),í_90%RH Dimensions: 126x65x27mm weight: 81g(not including battery) Optional accessories: other range 0-200um to 15000um RS-232C cable & software: 1.USB adaptor for RS-232C 2.Bluetooth interface.
It could test the surface field of permanent materials and working magnetic field of dc motor, amplifier, magnetic separator and permanent de-ironing separator. It also could be used in the measurement of remnant magnetism of mechanical processing, magnetic polarity, remnant demagnetizing field of products, to control the magnetic condition of Electroplating staffs and test the motor magnetism, leakage of electromagnetic field and ac space field. Main features 1. Small and light, easy to take, could meet all kind of on-site test requirements. 2. Power down automatically when no operation over 40 seconds.Lower voltage indicate.Super low power consumption design.It could be used more than 80 hours continuously. 3. Dc or ac peak hold 4. Dc and ac magnetic field, two range 0-200mt, 0-2000mt. 5. Dc field polarity judgement function. 6. One-click quick automatic zero adjustment. 7. Users can select the transverse and Longitudinal probes accordingly. Power 9v laminated cell inside Display 3.5 digits lcd Test range 0~~200mt, 0~~2000 mt Basic error: ~{!@~}1% Resolution Dc~{!a~}1 range: 0.00~~200.00mt, resolution: 0.01mt Dc~{!a~}10 range: 0.00~~2000.00mt, resolution: 0.01mt Ac~{!a~}1 range: 0.00~~200.00mt, resolution: 0.01mt Ac~{!a~}10 range: 0.00~~2000.00mt, resolution: 0.01mt Ac magnetic field frequency range below 400hz Temperature error -0.06%/~{!c~}c Operation environment Temperature : -10~{!c~}c~~40~{!c~}c, humidity: 35~~75% Probe interface 5 pin socket 0.5 kg . Plastic package l 150 x w 70 x h 25 mm
Use for power supply. Packing of 10 piece.
As per requirement As per requirement
Manual operation to microprocessor operated testers from 0-60kV, 0-80kV, 0-90kV and 0-100kV.
SFY-60A SFY infrared moisture meter Product attributes 1.Small in size and light in weight 2.Rapid and accurate in detection 3.Easy to operate 4.Red numeral tube used in the displaying instrument 5.Widely used 6.Available to computer and printer connection Our Products SFY infrared moisture meter is a new,rapid moisture detecting instrument based on thermal gravimetric theory While sample products are weighed by infrared moisture meter,the meter is Infrared Heating Unit and Water Evaporating Channel dry the sample products rapidly.During the process,moisture meter continuously measure and display the moisture content lost by the samples.The final numerical value is fixed and showed after the dry process is over.Compared with the traditional oven heating approach,nfrared heating has the advantage of achieving the maximum heating power within the minimum time span.Samples are dried under high temperature,which quickens the detecting time generally,a sample is moisture value is detected within several minutes.It is accurate in detection and easy to operate.Its displaying part is a red numeral tube with clear displaying results.The moisture meter can respectively display enumerated date of moisture,sample is initial and terminal data,detecting time span and temperature is initial and terminal data.Furthermore,the equipment is easily available for connection with computer and printer.Hence,SFY infrared moisture meter can be applied widely in most products which requires rapid moisture detection,ncluding medicine,cereals,seeds,tobacco,chemical,tea,food,meat textile and etc as well as in laboratory and manufacturing process in fields like agriculture and forestry,paper making.plastic or rubber making,textile and etc. Product is technical target: Weighing capacity:Generally:0~60g Specifically0~100g Minimum reading:0.002g Moisture readable: 0.01% .
GANZ measuring instruments are made according to the EN 60051;EN 61010-1, and DIN 43780 standards. The accuracy of the instruments is idnicated on the detailed data sheets. (0,5;1;1,5;2,5;3%). The dimensions of the cases and the cut-outs comply with the standard DIN 43700. The instrument cases are made of inflammable plastic according UL 94 V-1 or steel plate. See at the detailed technical data sheet at our website:www.ganzinst.hu.
We are offering eut monitoring system that includes eut monitoring, analysis and data recording. These eut monitoring systems analyzes data during the test for interference or failure conditions, and records test data for retrieval after the test is complete. It is designed as a stand-alone system to communicate with the main test system using our eut monitoring and test software. The eut (equipment under test) monitoring system combines the following: Monitoring instrumentation Video and audio equipment Software to provide eut signal monitoring (analog and digital) Eut stimulation Monitoring for visual or audio interference during testing The monitoring is enabled only after the test level is established with the main test system, since the EUT Monitoring System is fully synchronized with test system. These are appreciated because all parameters captured by the EUT Monitoring System during testing ensures to accurately recreate interference or failure points to resolve compatibility issues monitored. These systems are configured specifically to cater the test needs and can be configured for specialized requirements such as audio breakthrough required by mobile radio standards and ABS/TCS testing needed in automotive test standards. Our entire range of standard as well as customized seamless interface with main test system completes the control of the EUT Monitoring System from the control room console. System Components: EUT stimulation and monitoring instruments selected to cover applicable specifications and meet your price/performance requirements Video monitoring system using shielded color cameras to visually monitor equipment under test An audio monitoring system can supply as a stand-alone solution or built into the video camera system A system controller with application software that offers power to control monitoring equipment These are used to process and store data, graphics, and results of series measurements System cabling and switching to connect the control room with the chamber Shielded room allow test engineers complete control of the EUT monitoring system from the desktop Fiber optic links for analog and digital signal monitoring. We are offering Radiated Conducted EMS that is used for EMS Testing Many electronic products. The subassemblies must meet immunity testing requirements depending on the product's target marketplace. These are designed specifically to meet the requirements of specific environmental use and internal manufacturer's requirements. It also needs an engineer to control instrumentation from a variety of vendors and perform detailed test procedures for numerous specifications. These are known for integrating test instrumentation, system controls, positioning devices, and software to perform automated, semi-automated, and manual immunity measurements in an anechoic chamber, shielded room, or test cell. The range of test specifications is carefully evaluated to develop an integrated test environment covering the basic, generic, product family and product specific standards. The entire recommendation is based on proven system installations, in-house research and development, and extensive experience with dozens of test instrument suppliers. It result in a seamless interface the test system and the test environment. We are offering a range of Radiated Conducted EMI that is designed and manufactured to use in an anechoic chamber, shielded room, OATS, or test cell to perform automated, semi-automated, and manual emissions measurements. These systems are integrated with test instrumentation, system controls, positioning devices and software. This helps to test specific products or subsystems for electromagnetic emissions according to international, R&D and manufacturer-specific standards. Designed especially to meet customerÆs requirements, these receive the exact system solution. This is offered without unnecessary components and costs associated with off-the-shelf, "one size fits all" test systems. Further, we also offer turnkey solution for our Radiated Conducted EMI, which includes system designing and installation with dozens of test instrument supplies. The turnkey EMI Test System designed by us assist to meet product testing requirements. A typical system includes: EMI test instrumentation selected to cover applicable frequencies and meet your price/performance requirements. Antennas/LISNs/Clamps selected to match both test standards and test facility capabilities. Measurement Accessories such as switching and positioning devices that simplify control and increase efficiency. An EMI Main Control Console with instruments and system controls strategically placed to provide test engineers easy access to all functions, and a comfortable, ergonomically-correct work environment. A System Controller with Application Software that offers state-of-the-art power to perform emissions tests from pre-scan to final measurements and to control multiple EMI analyzers and receivers. Proven Solutions: Our test system developments are based on the systems in Europe, North America, and Asia. Each new system incorporates the latest technologies instead of an off-the-shelf approach to design and to explicitly cover the standards. It provides accurate, repeatable measurements and minimizes demands on your limited resources. We are offering Observation System that is appreciated by the clients for conforming to various international quality standards. These are known as Specific Absorption Rate Test Systems (SRC), which include SAR Measurements, System Components, Measurement System, Probes & Measurement Accessories and Position Controller & Positioning Robot. The detail description of Specific Absorption Rate Test Systems is as follows: The SAR System: It is used to measure electromagnetic fields and calculated SAR over a customer-specified frequency range. All tests are conducted in a shielded test room. SAR Measurements: SAR testing works with the thermal effects of human exposure to RF electromagnetic fields. It corresponds to the relative amount of RF energy absorbed of a device close to the body. The test is conducted to verify that the RF energy emitted by a device is within permissible limits for public exposure as defined by test standards. The SAR Measurement System is comprised of the following subsystems: Measurement System: It is an easy to use, flexible package optimized for dosimetric evaluation of radio products. The whole package includes Data Acquisition Electronics and system control computer. Probes and Measurement Accessories: Various broadband probes and support accessories are available based on test requirements. It includes probes to measure current distribution on radio products in free space, to measure fields inside fluids simulating body tissue and to test radiated emissions from mobile radio equipment. Position Controller and Positioning Robot: The automated robot positions the probe inside the tissue-simulating liquid over a precisely defined volume. The robot is controlled by a multiprocessor positioning device. Air tieght packing with container, steel packing, wooden packing
Electrical switch gear.