Product Usage The JZXC-H156 rectifier slow release relay is used as a filament supervisory relay in the electric centralized lighting circuit. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Mechanical properties Number of contact groups: 4QH; Identification pin number: 22, 53; Contact gap: not less than 1.3mm; Pallet gap: not less than 0.35mm; Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN; Contact uniformity error: not more than 0.20mm. Electrical characteristics Rating: AC51MA Magnetizing value: AC136Ma Release value: not less than AC12Ma Working value: not less than AC34ma Coil resistance: 78 (1±10%) Q2 The coils are connected in series, connect 1, 4, use 5, 6;
Product Usage The JZXC-H156 rectifier slow release relay is used as a filament supervisory relay in the electric centralized lighting circuit. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Mechanical properties Number of contact groups: 4QH; Identification pin number: 22, 53; Contact gap: not less than 1.3mm; Pallet gap: not less than 0.35mm; Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN; Contact uniformity error: not more than 0.20mm. Electrical characteristics Rating: AC51MA Magnetizing value: AC136Ma Release value: not less than AC12Ma Working value: not less than AC34ma Coil resistance: 78 (1±10%) Q2 The coils are connected in series, connect 1, 4, use 5, 6;
product name AC filament conversion relay: JZSJC2 product usage JZSJC2 AC Filament Conversion Relay is suitable for railway signal lighting circuit. When the main filament of the 12V, 25w dual-filament signal bulb is broken, the auxiliary filament will be lit through a set of movable break contacts to realize the conversion of the main and auxiliary filaments. , And alarm through another set of contacts. Applicable environment a) Temperature: -40~+60; b) Air pressure: not less than 70kPa (equivalent to 3000m above sea level); c) Relative humidity: not more than 90% (temperature -25C); d) Vibration: frequency 5H2~2H2, displacement amplitude not greater than 1mm, frequency 22H2-50H2, acceleration amplitude not greater than 20m/s2; e) There should be no harmful gas causing explosion hazard around, and dust-proof measures should be taken. Mechanical properties Contact gap: not less than 0.8mm; Dynamic contact pressure: not less than 150mN; Dynamic breaking contact pressure: not less than 150mN; Contact uniformity error: not more than 0.1mm; The joints are formed together: not less than 0.1mm. Electrical characteristics Rated current: 2.1AAC; Working value: not more than 1.5AAC; Release value: not less than 0.5AAC; Contact resistance: no more than 0.052 Insulation resistance The temperature of the relay and socket is 15C~35â??, the relative humidity is 45%~80%, and the insulation resistance should not be less than 100M�©. Insulation withstand voltage Between the coil winding and other parts of the relay, the insulation withstand voltage between each contact and the contact and the ground should be able to withstand AC sine wave 50Hz, 1000V effective value voltage for 1Min, there should be no breakdown or flashover. Product electrical life Wei Electric implements broken wire conversion according to the lighting circuit, 15 to 20 actions per minute, and its electrical life is not less than 3*105 test method Requirements for test satellites, meters, and power supplies The accuracy of the measuring gauge should not be less than 0.02mm; The accuracy of the feeler gauge should not be lower than level 2; The measurement error of the dynamometer should not be greater than 2%; The accuracy of the AC ammeter used for testing should not be lower than level 1; The power supply voltage fluctuation range should not exceed 5%, the waveform is a sine wave, and the frequency is 50�±1Hz. Characteristic test The electrical characteristics test circuit of the relay is shown in the figure below.
product name AC filament conversion relay: JZSJC2 product usage JZSJC2 AC Filament Conversion Relay is suitable for railway signal lighting circuit. When the main filament of the 12V, 25w dual-filament signal bulb is broken, the auxiliary filament will be lit through a set of movable break contacts to realize the conversion of the main and auxiliary filaments. , And alarm through another set of contacts. Applicable environment a) Temperature: -40~+60; b) Air pressure: not less than 70kPa (equivalent to 3000m above sea level); c) Relative humidity: not more than 90% (temperature -25C); d) Vibration: frequency 5H2~2H2, displacement amplitude not greater than 1mm, frequency 22H2-50H2, acceleration amplitude not greater than 20m/s2; e) There should be no harmful gas causing explosion hazard around, and dust-proof measures should be taken. Mechanical properties Contact gap: not less than 0.8mm; Dynamic contact pressure: not less than 150mN; Dynamic breaking contact pressure: not less than 150mN; Contact uniformity error: not more than 0.1mm; The joints are formed together: not less than 0.1mm. Electrical characteristics Rated current: 2.1AAC; Working value: not more than 1.5AAC; Release value: not less than 0.5AAC; Contact resistance: no more than 0.052 Insulation resistance The temperature of the relay and socket is 15C~35, the relative humidity is 45%~80%, and the insulation resistance should not be less than 100M.
Product Usage Programmable time relays include JSBXC-780, JSBXC-820, JSBXC-820, JSBXC1-850, and JSBXC1-870 series relays. Each type of relay has four types of warm-up time to choose from, among which JSBXC1-870 series The heating time can also be changed according to the special requirements of users. The relay is used as a delay control in the circuit. Applicable environment a) Ambient temperature: -5~+40; b) Relatively moderate: not more than 90% (temperature +25); c) Air pressure: not less than 70KPa (equivalent to an altitude below 3000m); d) Vibration: the frame rate is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Rated voltage: DC 24V, voltage fluctuation range 24X (1�±10%) V; f) Working position: horizontal; g) There is no harmful gas causing explosion hazard around, and good dust-proof measures should be applied. Mechanical properties 1614996944256898.jpg Electrical characteristics .jpg Note: The error range of the resistance value of the relay coil is ±(nominal resistance value10%) Time characteristics
Product Introduction The JJJC7 AC enhanced contact relay is an important element in the interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and the opening and closing of the signal machine. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage The JJC7 AC enhanced contact relay is used in the distributed power supply screen. Features 1. The JJJC7 type relay is an AC 220V heavy spring force type reinforced contact electromagnetic relay. 2. The relay magnetic system is a clap-on AC magnetic system, which is composed of an iron core, a coil and an armature. 3. The use of silver-silver oxidation requires contacts, which has the characteristics of strong anti-adhesion and low contact resistance. 4. The relay contact system consists of two parts: ordinary contacts and enhanced contacts. There are two groups of moving on and off switching ordinary contacts; the two sets of moving on and off switching enhanced contacts, the structure of the ordinary contacts is the same as the stepless relay, and the strengthened contacts Specially designed high-power contacts. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Insulation withstand voltage Under the standard atmospheric conditions of the test, the absolute resistance of the relay should not be less than 100MQ. Under the condition that the air pressure is not lower than 86kPa (equivalent to the altitude below 1000m), the insulation withstand voltage of the relay should be able to withstand AC sine wave 50Hz, 2000V rms voltage, there should be no breakdown flashover after 1min, the voltage when repeating the test Should be 75% of the original test voltage value.
Applicable environment a) Ambient temperature: -5~+40; b) Relatively moderate: not more than 90% (temperature +25); c) Air pressure: not less than 70KPa (equivalent to an altitude below 3000m); d) Vibration: the frame frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Rated voltage: DC 24V, voltage fluctuation range 24X (1±10%V; f) Working position: horizontal; g) There is no harmful gas causing explosion hazard around, and good dust-proof measures should be applied. Mechanical properties 1614998643577125.jpg Precautions a) The identification pin numbers of the programmable time relays are the same. Please confirm the corresponding slow suction time of the corresponding type of relay before use. b) Terminals 1, 2, 3, and 4 of the two coils of the relay are directly connected in parallel with the two diodes on the printed circuit; therefore, when measuring the electrical characteristics of the relay, the positive pole of the power supply must be connected to the terminals 1, 3, and the negative pole of the power supply must be connected to the terminals 1, 3. On terminals 2, 4. C) Contacts 11 and 12 are already occupied by the relay, and the number of contacts that can be used by the user is 2QH, 1Q. d) The position of the relay contact system is shown in Figure 1. When in use, the socket must be equipped with an identification pin. e) The use environment of the relay should have good ventilation conditions and dust-proof equipment. And used in specially designed circuits; in special circumstances, the electrical characteristics and contact capacity of the relay should be considered to ensure the reliable operation of the relay.
Product Introduction The JJJC5 AC enhanced contact relay is an important element in the interlocking equipment, and the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the way, and control the opening and closing of the signal machine. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage The JJ small C5 AC enhanced contact relay is used as an indicator light power supply supervisory relay in the power supply screen of the small station. Mechanical properties Number of contact groups: 2QHJ; 2QH Identification pin number: 13, 43; Ordinary contact gap: not less than 1.3mm; Strengthen the contact gap: not less than 4mm; Ordinary pallet gap: not less than 0.35mm; Reinforce the gap of the support plate: not less than 0.1-0.3mm; Ordinary contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN; Strengthen the contact pressure: the dynamic contact point is not less than 600mN; the dynamic disconnection point is not less than 300mN; Contact uniformity error: not more than 0.20mm.
Product Introduction Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage The JJC1 AC enhanced contact relay is a reversible motor control relay in the power supply screen. It can replace JZJXC-7200 rectifier strengthened contact relay. Features 1. The JJC type AC enhanced contact relay is an AC 24V heavy elastic type enhanced contact electromagnetic relay. 2. The relay magnetic system is a clap-on AC magnetic system, which is composed of an iron core, a coil and an armature. 3. It adopts silver-silver cadmium oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance. 4. The relay contact system is composed of two parts: ordinary contacts and enhanced contacts. There are two groups of movable and broken ordinary contacts; four groups of movable and closed enhanced contacts. The structure of ordinary contacts is the same as that of non-polar relays. The enhanced contacts are specially designed high-power contacts. Mechanical properties Number of contact groups: 4QJ; 2H Identification pin number: 12, 54; Ordinary contact gap: not less than 1.3mm; Strengthen the contact gap: not less than 5mm; Ordinary pallet gap: not less than 0.35mm; Reinforce the gap of the support plate: not less than 0.1-0.3mm; Ordinary contact pressure: dynamic breaking contact is not less than 150mN; Strengthen the contact pressure: the moving and closing contact is not less than 600mN; Contact uniformity error: not more than 0.20mm.
Product Usage The JC type AC relay is used as a buck-boost control relay, a signal switch track power supply supervisory relay, and a main screen and a backup screen conversion relay in the power supply screen. Can replace JZXC-20000 rectifier relay. Features 1. The relay is an AC 220V heavy spring force electromagnetic relay with reinforced contacts. 2. The relay magnetic system is a clap-on AC magnetic system, which is composed of an iron core, a coil and an armature. 3. It adopts silver-silver oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance. 4. The contact system is composed of ordinary contacts. There are four groups of moving on and off conversion ordinary contacts and two groups of moving and closing ordinary contacts. The structure of the ordinary contacts is the same as that of a non-polar relay. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Dimensions
Executive standard GB/T7417-2010 "Railway Signal AX Series Relay" product structure The electromagnetic system of the stepless enhanced contact slow release relay is the same as that of the stepless slow release relay (JWXC-H340). The magnetic circuit system of the JWJXC-H125/80 stepless enhanced contact slow release relay adds a copper short-circuit ring to make the slow release time longer. The contact system consists of two parts: ordinary contacts and enhanced contacts. The structure of ordinary contacts is the same as that of non-polar relays, and the reinforced contacts are specially designed high-power contacts and arc wave devices. Product Usage The transmission relay is one of the important equipment in the AC counting code automatic blocking equipment. The DC pulse sent by the electric code transmitter is transformed into an AC pulse by the relay, and then sent to the track circuit. JCZC2-2000 transmission relay is used in the station. Features Heavy spring force relay. It is necessary to install a shock absorber when in use. Mechanical properties Number of contact groups: 2QHJ; 2QH Identification pin number: 14, 53; Strengthen the contact gap: not less than 1.5mm; Ordinary contact gap: not less than 0.8mm; Strengthen the contact pressure: the front contact is not less than 450mN; the rear contact is not less than 450mN; Ordinary contact pressure: the front contact is not less than 250mN; the rear contact is not less than 250mN; The air gap between the iron core and the street iron when the relay is working: not more than 0.20mm. Strengthen the contact pressure on the transmission rod: not less than 100mN. Strengthen the joint travel: not less than 0.1mm. Common travel of common contacts: not less than 0.25mm. Radial travel distance of street iron: 0.3mm-0.7mm. Street rail vertical travel: 0.3mm-0.5mm. Street rail axial travel: 0.05mm-0.15mm.
JZXC-0.14 type rectifier relay is an important element in interlocking equipment, and is the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the way, and control the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operation services. The automatic control systems in various fields all use relays. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage The JZXC-0.14 type rectifier relay is used in the signal circuit for the filament supervision or conversion relay for the electric concentration of small stations and the local power supply in the automatic block section. Features 1. The relay is a heavy elastic rectifier electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized. 2. It adopts silver-silver cadmium oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance. 3. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and a stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the magnetization of the ferromagnetic parts of the magnetic circuit, and ensure the reliable fall of the relay. 4. The relay is composed of a half-wave rectifier circuit and an infinite relay. The input of the rectifier is alternating current, and the output of the rectifier is ~ Darudapin current 1, current. 5. The relay contact system consists of common contacts, with four groups of common contacts for switching on and off. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Dimensions Relay: 165mm 49mm 163mm (length width height) Socket: 157mm 48mm 22mm (length width height)
Product Usage The JWXC-2.3 type infinite relay is used as a DC track relay in the signal circuit. Features 1. The relay is a heavy elastic DC electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized. 2. It adopts silver-silver cadmium oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance. 3. The magnetic circuit adopts electromagnetic pure iron material with small residual, and installs the stop piece at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the magnetization of the ferromagnetic parts of the magnetic circuit, and ensure the reliable fall of the relay. 4. The contact system is composed of ordinary contacts, and there are four groups of ordinary contacts for switching on and off. 5.The rated current of the relay is 280mA DC. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25); c) Air pressure: not less than 70KPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. product structure Infinite relay is the typical structure of Ax series relay, which is composed of electromagnetic system and contact system. The electromagnetic system includes coil, iron core, choke and armature. The coil is installed horizontally on the iron core, and is divided into a front coil and a back coil. The use of dual coils is to enhance the flexibility and flexibility of the control circuit, which can be controlled by a single coil or a series of double coils according to the circuit needs. The armature is fixed on the blade of the iron by a butterfly-shaped steel wire, which is flexible in movement. There is a heavy hammer in the transmission part of the armature to ensure that the relay armature returns reliably by gravity. The number of weights installed is determined by the structure of the relay contact system, and should be able to ensure the reliable release of the relay. A stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit of the relay, prevent the ferromagnetic parts of the magnetic circuit from magnetizing, and ensure that the relay falls reliably. The iron core, choke iron and armature of the relay are made of electromagnetic pure iron, which has high magnetic permeability and small remanence. Installation method
Product Usage The JZXC-H18 rectifier slow release relay is used as a filament supervisory relay in the electric centralized lighting circuit. The use of dual coils is to enhance the flexibility and flexibility of the control circuit, which can be controlled by a single coil or a series of double coils according to the circuit needs. The armature is fixed on the blade of the armature by the butterfly-shaped steel wire, and it moves flexibly. There is a heavy hammer in the transmission part of the armature to ensure that the relay armature returns reliably by gravity. The number of weights installed is determined by the structure of the relay contact system, and should be able to ensure the reliable release of the relay. A stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit of the relay, prevent the ferromagnetic parts of the magnetic circuit from magnetizing, and ensure that the relay falls reliably. The iron core, vehicle iron and armature of the relay are made of electromagnetic pure iron, which has high magnetic permeability and small remanence. Product characteristics Mechanical characteristics Number of contact groups: 4QH; Identification pin number: 13, 53; Contact gap: not less than 1.3mm; Pallet gap: not less than 0.35mm; Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN; Contact uniformity error: not more than 0.20mm. Electrical characteristics
Product Introduction JWXC-1000 type infinite relay is used to close and open the special multi-way switch of signal control circuit. It is an important part of railway signal. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the action of the relay directly affects the reliability and safety of the signal system. Features JWXC-1000 type infinite relay is one of the main components in railway signal equipment. Its reliability and safety in use are necessary requirements to ensure the normal operation of various automatic control and remote control signal equipment. Product function The signal relay is an important component in the interlocking equipment, and is the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the route, and control the opening and closing of the signal machine. Its reliability, availability, maintainability and the whole line are the keys to the safety of railway transportation and operation services. Product Usage The JWXC-1000 type infinite relay is used as a general relay in the signal circuit. Executive standard GB/T7417-2010 "Railway Signal AX Series Relay" Product Usage JWXC-1000 type infinite relay (hereinafter referred to as relay) is used as a general relay in the signal circuit. Applicable environment The applicable environment of the relay is: a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Applicable characteristics Mechanical properties Number of contact groups: 8QH; Identification pin number: 11, 52; Contact gap: not less than 1.3mm; Pallet gap: not less than 0.35mm; Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN; Contact uniformity error: not more than 0.20mm. Electrical characteristics
3. When repairing or replacing the relay, first remove the national relay spring, and then pull out the relay. Do not use excessive force or shake left and right when pulling it out, as it may damage the relay or socket. Faults and troubleshooting methods 1. The relay contact has no output The analysis and elimination methods of the relay contact without output are as follows: (1) Make sure that the relay and socket should be reliably plugged in; (2) Check that the relay should not be mechanically blocked. If foreign matter in the relay blocks the armature, the armature cannot work reliably (forward rotation) or release (reverse rotation), and the contacts cannot be reliably contacted; (3) Check that there should be no foreign matter between the contacts, there is foreign matter between the contacts, and the contacts cannot be reliably contacted; (4) Check that the contact resistance of the relay contact should not be too large. 2. The relay does not work or the relay with a pole cannot be reversed in the forward direction be reliably released.
Product Features JSDPC-1000 dynamic relay, JSDPC-820 dynamic relay, and JSDPC-830 dynamic relay were once used in microcomputer interlock interface circuit. At present, JSDPC-1000 dynamic relays, JSDPC-820 dynamic relays, and JSDPC-830 dynamic relays have ceased to be used on large railways, and are only used in hump circuits when users require them. Features 1. Two-way dynamic control signal relay. 2. Controlled by dynamic pulse signal. 3. Dynamic pulse control signal: JSDPC-1000 dynamic relay is 24V, 2.5Hz. JSDPC-820 dynamic relay is 24V, 1Hz. JSDPC-830 dynamic relay is 24V, 5Hz.
roduct Usage The transmission relay is one of the important equipment in the AC counting code automatic blocking equipment. The DC pulse sent by the electric code transmitter is transformed into an AC pulse by the transmission relay, and then sent to the track circuit. JCZC1-72 transmission relay is used for automatic blocking interval. Features Heavy spring force relay. Dimensions 165mm 49mm 163mm (length width height) Installation method The relay socket is installed on the combination pear (cabinet) with bolts, and the relay is horizontally inserted into the socket and clamped with a hanging spring. Relay identification pin numbers 13, 53. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. maintenance Daily maintenance and maintenance items are as follows: a) Keep the relay and socket clean; b) Observe whether the relay operation status is normal; c) The relay should be replaced in time for abnormal operating conditions and serious contact burnout. Regular maintenance: In the electrical life and life management cycle of the relay, the maintenance cycle of the stepless relay and the rectifier relay should be five years; The overhaul period of stepless enhanced contact relays, poled relays and biased pole relays should be three years; The overhaul period of stepped reinforced contact relays should be one year. Appearance inspection and performance
Product Introduction JWJXC-H125/0.44 stepless enhanced contact slow release relay is an important component in interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and control the opening and Close and so on. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage JW.JXC-H125/0.44. The stepless strengthened contact slow release relay is used as a general relay in the signal circuit. Applicable environment a) Ambient temperature: -40~+60 b) Relative humidity: not more than 90% (temperature +25); C) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Structural characteristics Mechanical properties Number of contact groups: 2QH, 2QJ, 2H; Identification pin number: 15, 55; Ordinary contact gap: not less than 1.3mm; Strengthen the contact gap: not less than 2.5mm; Ordinary pallet gap: not less than 0.35mm; Reinforce the gap of the support plate: not less than 0.1-0.3mm; Ordinary contact pressure: dynamic closing or positioning contact not less than 150mN; dynamic breaking or reverse position contact not less than 150mN; Strengthen the contact pressure: the dynamic closing or positioning contact is not less than 400mN; the dynamic breaking or reverse position contact is not less than 300mN; Contact uniformity error: not more than 0.20mm.
Product Introduction The JZXC-480 rectifier relay is an important component in the chain equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the route, and control the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays. Product Usage The JZXC-480 rectifier relay is used as an AC rail and AC accident relay in the signal circuit. test method Requirements for testing measuring tools, meters, and power supply (1) The accuracy of the measuring tool for measuring the shape and installation dimensions should not be less than 0.05mm; the accuracy of the feeler gauge should not be less than level 2; the measurement error of the force measurement should not be greater than 2%. (2) The accuracy of the DC voltmeter and ammeter used for testing should not be less than 0.5, and the accuracy of the AC (50Hz) voltmeter and ammeter should not be less than 1 (3) The power supply voltage should remain stable, and its fluctuation range should not exceed 5%. The DC power supply should be a DC generator, battery or AC full-wave rectifier power supply (except for special regulations, the ripple factor should not be greater than 5%). The waveform of the AC power supply should be a sine wave with a frequency of 50 Hz. Features The relay is composed of a DC infinite relay and a full-wave rectifier circuit. Applicable environment a) Ambient temperature: -40â??~+60â??; b) Relative humidity: not more than 90% (temperature +25â??); c) Air pressure: not less than 70kPa (equivalent to below 3000m above sea level); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Dimensions 165mm 49mm 163mm (length width height) Installation method The relay socket is installed on the combination frame (cabinet) with bolts, and the relay is inserted into the socket horizontally and clamped with a hanging spring. Relay identification pin numbers 13, 54. Mechanical properties Number of contact groups: 4QH; 2Q Identification pin number: 13, 55; Contact gap: not less than 1.3mm; Pallet gap: not less than 0.35mm; Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN; Contact uniformity error: not more than 0.20mm.