Transformer
Ferrite cores 1 mnzn ferrite cores for switch power transformers 2 mnzn ferrite cores for crt monitor transformers 3 high-magnetic-conductivity mnzn ferrite cores for pulsed transformers, broadband transformers, filters, and inductance 4 mnzn ferrite core for emi resistant applications 5 nizn ferrite cores 6 nizn ferrite cores for emi resistant applications
6kv-110kv transformer 1)6kv-35kv sc9, sg10 series insulation dry power transformer 2)6kv-110kv s9, s10, s11 series oil immersed transformer 3)6kv-35kv dz9 series oiled immersed single-phase transformer 4)6kv-35kv the single-phase oil-filled pole-mounted distribution transformers 5)6-40.5kv yb, zbw1, zbw3, jbw series power combined substation Export packing
Low, medium and high voltage transformers 110kV Class Power Transformers General The110kV class low loss transformers are developed by Huapengour workshop through years of service experience and careful analysis of the advantages and disadvantages of the transformers of different manufacturers, both domestic and abroad, and are featured by low loss, low partial discharge, low noise, high strength against short circuit, and high reliability in service. Its outstanding performance has won high reputation throughout China, and the world, and are highly appreciated by experts of the circle. Transformers can be made with welded tank cover and/or flange , Thus obviated from the necessity of lifting out the active part for inspection after arrival on site. Partial discharge level: apparent discharge < 80pC at 1.5 times rated voltage. Noise level : below 58 dB for transformers 63MVA and below with AN cooling Losses: no-load loss 30% lower than specified by GB/T 6451-1995 Reliability: no damage or oil leakage have been found in transformers in service up to the present Short-circuit withstand capability: Our SZ9-31500/110,SSZ-50000/110 transformers successfully passed short-circuit test in National Transformer Quality Inspecting and Testing Center, and in CESI Laboratory of Italy. Winding 1. Partially interleaved continuous winding is used for HV winding to improve its behavior under lightning impulse, because of its more uniform voltage distribution. 2. All the spacers and vertical strips are rounded at corners, in order to obtain a more reliable insulation structure. 3. Zig-Zag directional flow is provided inside the windings, so that all parts of the windings are better cooled, resulting in lower winding temperature rise, and specifically lower hot-spot temperature, thus the insulation life of the transformer is prolonged. 4. Separate regulating windings are provided for both the 110kV high voltage and the 35kV medium voltage side, so that a more balanced ampere-turn is obtained in spite of tap-changing, the short-circuit withstand capability is thus promoted. Radially, the windings of a phase assembly are tight-fit, little space is left between the core and the low-voltage cylinder, and between the windings. All the vertical strips and cylinders are thoroughly dried before assembly, so that a tight phase assembly can be finally obtained. Core 1. High permeability grain oriented high quality cold-rolled sheets are used for the fabrication of core. The sheets are cut on automatic cutting line made by Georg Co. of Germany or Soenen Co. of Belgium. The burrs are controlled within 0.02mm. 2. The core is stacked without stacking the upper yoke, the upper yoke sheets are placed into position after the winding blocks are mounted on the core. The joints of the core sheets are mitred 45fpjoint with step-lap. The stacked core is pressed under even pressure and the edge of the sheets are painted with epoxy resin, so that a straight, robust, integral structure is obtained, helping to reduce core loss and noise. 3. Wooden strips are driven into the space between core and LV cylinder. The yoke is kept tightened by epoxy-resin impregnated glass tape, while the lower yoke is pressed against the wall of the lower tank through threaded bolts. The active part of the transformer is in addition kept in position by devices at three places between the upper yoke and the tank cover in such a way that the active part cannot be displaced during transportation.
Transformer Grade-h insulation amorphous alloy transformer 10kv-35kv 30kva-2500kva This product is another novelty developed by employing proven techniques from both both united state and china on the basis of our company's successful production of model sg10 grade-h insulation unrestricted venting dry-type transformer. It lowers the no-load loss and open-circuit loss intensively, and is of superior performance, thus it is currently the state-of-the-art dry-type transformer in the world. This product is safe, reliable, environment friendly and energy saving, and can go deep into the load center and is applicable to modern city's high-density and heavy-load developmental needs.
Transformer Grade-h insulation amorphous alloy transformer 10kv-35kv 30kva-2500kva This product is another novelty developed by employing proven techniques from both both united state and china on the basis of our company's successful production of model sg10 grade-h insulation unrestricted venting dry-type transformer. It lowers the no-load loss and open-circuit loss intensively, and is of superior performance, thus it is currently the state-of-the-art dry-type transformer in the world. This product is safe, reliable, environment friendly and energy saving, and can go deep into the load center and is applicable to modern city's high-density and heavy-load developmental needs. High temperature resistant liquid-immersed transformer 10kv 30kva-3150kva 35kv 50kva-31500kva
Transformer bobbins Injected phenolic material and inserted pins 39x34x29cm about 9kgs
Transformer bobbins Made from Phenolic, PBT, Rynite or Nylin
Product description Insulating boots and gloves withstand voltage device is a power frequency power supply with low voltage working voltage of 220V/50Hz for insulating boots and gloves. According to the principle of electromagnetic induction, the input voltage is changed to the minimum value required for the test. high pressure. Insulating boots (gloves) withstand voltage test device generally consists of a special dedicated test box, an intelligent power frequency withstand voltage console, and a power frequency withstand voltage test transformer. A special water tank can be customized according to needs to test 6-8 insulated boots or 6 insulated gloves at a time, and display the leakage current of the insulated boots or insulated gloves at the same time. The intelligent power frequency withstand voltage console is equipped with overcurrent protection and zero protection. Time protection and alarm function. The preventive voltage resistance test device for insulating boots and gloves is a special product developed and produced according to the needs of users according to the test procedures of insulating boots (gloves). The selection has an automatic boost (buck) function, automatically reads the leakage current of each test product, the whole process is automatically completed, and the test data is automatically printed, which effectively solves the previous non-standard test methods, thereby simplifying .Simplifies the test procedure and improves the test speed. More reliable identification of parameters such as leakage current and power frequency withstand voltage of insulating boots (gloves). To ensure the safety of test personnel, it is an ideal pre-treatment of insulating boots (gloves) to protect power frequency withstand voltage test equipment. Technical Parameters Input voltage AC220V 50 Hz Output voltage 0~30kV Capacity 3kVA Test number 3 pairs each time Quality Gloves (insulating boots) test car: 80kg; power frequency withstand voltage test bench: 70kg
Rc model like car, botat, flight, gun battery, rechargeable lipo battery, lipo battery charger, virtual flybarless system, battery adopter, brushless motor.
Electrical panels , solar power plant , automation solutions.Design, engineering, manufacturing, testing and commissioning
Color-coded housings and terminals With options for color coding, you can easily identify and manage the connections when color matching of housing and wires is done. This can significantly help for easy installation and easy cable management. Most HVAC applications typically utilize similarly-configured wire-to-wire connectors. With color coding, incorrect connector insertion and mismating can be prevented. Rugged consumer and medical application This can be used for applications subject to shock, vibration, or rough handling that can dislodge terminals and cause signal interference. Friction and positive-lock options Built with friction and positive lock options, this connector provides high-retention force for a reliable connection in rugged environments. Reliable TPA Feature The variety of Terminal Position Assurance (TPA) types, not only facilitates correct mating but also gives the insurance that terminals are fully locked in the correct position. High Current Carrying Capabilities The support for high voltage and current (300V/15A) features a more robust build than blanked terminals. Accept both male and female terminals The housing will accept both male and female terminals and are polarized to eliminate and prevent mismating. Facilitates heat dissipation and low engagement force The different wire-to-wire connector types are equipped with RMF solutions for lower friction solution between the contacts, making insertion and removal of the device easier, while eliminating the need for complex mechanisms. Advantages Material and Packaging of Molex 5.08mm Pitch Wire-to-Wire Connector Using a UV-Resistant Thermoplastic Material for Enhanced Connector Performance The housing components are injection molded Nylon66, UL 94V-0. These are scientifically proven to resist UV-radiation than normal plastic, making sure the connectors are well-protected, reducing the risk for early degradation and increased cycles/minute of the connector subjected to harsh environments. Tape and Reel Packaging for SMT Components STC uses state-of-the-art tape and reel equipment to package a variety of components. The tape and reel packaging strip has accurately sized cavities for the terminal height, width, and depth, secured tightly, maintaining consistent position during transportation. You can expect that your wire-to-wire connector package is undisturbed during the trip and has maintained its vitality even during your production stages, which is why a lot of our customers have raved about our product for both cheaply-priced and, at the same time, resembles the Molex 5.08mm pitch wire-to-wire product with an industry-standard .093 pin and socket in performance and quality. TOP
Distribution transformer, power transformer, compact substation, servo stabilizer, linear servo stabilizer, vcb, rmu, ht panel, lt panel.
Ac machine, ac service station, ac r134a refrigerant flush machine, recycling recharging recovery, ac refrigerant recycle recharge recovery machine, ac recovery machine, ac recharge machine, ac service machine, wholesale ac service station, manufacture ac service station.
Power transformers, distribution transformers, rectifiers, furnace transformers, vcb panels, servo stabilizers, electrical panels, ht avrs, power factor panels and dry type transformers..
HV transformer, generator, ionizer, ozone generator, photo-catalyst, ozone ion generator, air pump, automatic drain devices, skincare machine, electrostatic precipitator, ion air blower, neon sign.
Solar panel , solar system , solar projects , electric equipment.Trade
Inverter, battery, solar panel, stabilizer, cctv, generator, water purifier, electrical wiring, net meter solar on grid, solar water heater, building material hardware, electrical hardware.
Diesel engine spare parts, pt. pump & injectors, overhauling of cummins diesel engines & components and , engine electrical parts cummins fuel injectors, cummins electric controller, cummins pt pump, aftercooler, cummins spare parts.Trader and exporter
Electronics Weighing Scale Ms Fabrication And Power Press Parts.