Warranty 1 year Place of Origin Guangdong, China Brand Name Rawsuns Model Number RSG240 Type Synchronous Motor Frequency 50/60Hz Phase Three-phase Protect Feature IP 67 Efficiency 95% Product Name Rawsuns generator SAE motor ev kit electric boat RSG240 Application Large tonnage vehicles and boat flywheel shell SAE number 3 rated power (kw) 21 Peak power (kW) 35 Rated torque (Nm) 144 Peak torque (Nm) 240 Rated speed (rpm) 1400 Peak speed (rpm) 3500 peak efficiency 95%
Either one or two VM600Mk2/VM600 RPS6U rack power supplies can be installed in a VM600Mk2/ VM600 ABE04x system rack. A rack with one RPS6U power supply (330 W version) supports the power requirements for a full rack of modules (cards) in applications with operating temperatures up to 50C (122F).
Brand New F7126 HIMA Power Supply Module
Manufacturer : HIMA Product No. : F7131 Product type : Power supply monitoring with buffer batteries Monitors the system voltage 5 V generated by the 3 power supplies max. 3 LED-displays at the front of the module 3 test bits for the central modules F 8650 or F 8651 for the diagnostic display and for the operation within the user's program For the using within the additional power supply (assembly kit B 9361) the function of the power supply modules in it could be monitored via 3 outputs of 24 V (PS1 to PS 3)
The 5 V DC power needed for the microprocessor system and as control current for the I/O modules is generated from the 24 V DC power of the system via clocked 24 V DC / 5 V DC power supply modules bearing the F 7126 identification. One central rack can be equipped with a maximum of 3 power supply modules. The power supply modules are switched in parallel. One or two power supply modules are usually able to supply the PES. A further power supply module is used to increase availability.
Email me your inquiry,I'll offer you the most competitive price! We are the supplier for industrial automation spare parts.We specialize in PLC module, DCS card pieces, ESD system card pieces, vibration monitoring system card pieces, steam turbine control system module, gas generator spare parts, we have established the relationship with famouse PLC DCS product maintenance service providers in the world.
BC810K02-eA ABB 3BSE031155R2 CEX-bus Interconnection Unit Manufacture ABB Model BC810K02-eA PN No. 3BSE031155R Catalog AC800M Description CEX-bus Interconnection Unit Origin Sweden/Malta/India HS CODE 85389091 Dimension 25*15*10 (CM) Weight 0.8 kg NEW AND ORIGIN ITEM IN STOCK WITH ONE YEAR WARRANTY Hope anyone enquire from us,pls click this sales7@nseauto.com 1. lower your support costs 2, Provide on-going availability of automation replacement parts Quantity available: 1 Warranty: 12 months. Lead time: 1-2 working days. Terms of payment:T/T and Western Union. Courier partners: DHL, UPS, TNT, FedEx and EMS. Technical specification, manuals and data sheets
Automatic lightning surge generator (Lightning surge immunity tester) SG61000-5 is used to assess the power cord and connect the internal switch stood in line to connect the internal switch to provide a common basis for switching the natural world and lightning caused by the high-energy transient interference performance. Performance fully meets the IEC 61000-4-5, EN61000-4-5 and GB/T17626.5 standards. Specifications: Product Model SG61000-5SA SG61000-5SB SG61000-5 SG61000-5H-SP SG61000-5T Output Voltage (Open) 1.2/50�¼s�20% 1.2/50�¼s�20% 1.2/50�¼s�20% 1.2/50�¼s�20% 1.2/50�¼s�20% Output Current (Short) 8/20�¼s�20% 8/20�¼s�20% 8/20�¼s�20% 8/20�¼s�20% 8/20�¼s�20% Output Impedance 2�© and 12�© 2�© and 12�© 2�© and 12�© 2�© 12�© and 500�© 2�© and 12�© Output Voltage Range 0~4.8KV�10% 0~4.8KV�10% 0~6KV�10% 0~10KV�10% 0~6KV�10% Output Current Range 0~2.4KA�10% 0~2.4KA�10% 0~3KA�10% 0~5KA�10% 0~3KA�10% Surge Repetition 1~9999 times 1~9999 times 1~9999 times 1~9999 times 1~9999 times Interval Time 20~9999s 20~9999s 20~9999s 30~9999s 20~9999s Polarity Positive, Negative or Positive/Negative automatic Phase Shift Asynchronous, Synchronization 0�~ 360� or Specific Angle Special Function N/A Built-in surge voltage and current probe (1000:1), connect with LISUN OSP1102 directly Operation Way Button Input Touch screen with super big LCD and built-in Windows CE Dimensions (WxDxH) 44x45x35cm 44x45x35cm 44x45x35cm 56x69x155cm 44x45x55cm Gross Weight About 30kg About 30kg About 30kg About 270kg About 48kg Coupling/Decoupling Network (CDN) Includes a 16A single phase CDN Includes a 20A 3phases CDN Isolution Transformer for EUT (Option) LISUN ITEU-SP4K (220V Single phase) or ITUS-SP2K (110V) Remark: 12KV, 15KV, 20KV and more higer voltage Surge Generator can be designed according to customer request. 6KV Short Circuit Current Output Waveform (780:1) 6KV Open Circuit Voltage Output Waveform (1000:1)
Galvanized Tower and Tower Parts for Switch Yard and Transmission Lines up to 400 kv Ratings
Galvanized Monopole / Telecom Towers (Angular Or Tubular)
As one of the leading power steering trainer (toyota corolla electric power steering system) manufacturers and suppliers in China, we warmly welcome you to buy power steering trainer (toyota corolla electric power steering system) made in China here from our factory. All...
CAT Generator available USD5775000 plus VAT Model 3516 2000kva // 6 pcs 5% comission
CAT Generator available in UAE USD714,000 plus VAT for 02 pcs 3000 KVA 2016 model and all of them 0 working hours
Product description The impulse voltage generator intelligent measurement and control system is the latest programmable control system and consists of two parts: Automatic control of pulse voltage generator program and automatic analysis of pulse signal measurement. The General Conditions of Use Altitude: 1000m Ambient temperature: -5 40 Relative humidity: 90 20 Use of the environment: indoor Non-conductive dust Grounding resistance 0.5 No fire or explosion hazard Earthquake resistance: 8 magnitude There is no gas that corrodes metal and insulates Impulse voltage generator (2) Supply voltage waveform is the actual sine wave, waveform distortion rate 85% (more than 90% when no load 300PF); (2)Truncated wave: cut-off time (2-6) 10% s, zero-crossing coefficient 0.3% (3)Standard operating impulse voltage wave 250 20% s / 2500 60% s, The impulse voltage waveform parameters and their deviations are in line with the requirements of the national GB311 and GB16927 standards. 7, the lowest output voltage is greater than 10% of the nominal voltage 8. Duration of use: Above 70% of rated voltage, it can be continuously operated every 120 seconds after charging and discharging. It can be continuously operated after charging and discharging every 60 seconds under 70% of rated voltage. One computer is used for control and waveform analysis 18-inch LCD monitor, strong anti-interference and long life WINDOWS XP, OFFICE 2003, LabVIEW related driver software, ACE measurement and control software package,built in
Products Introduction Ultra-low frequency dielectric strength testing is another method of power frequency withstand voltage testing, because large-capacity testing is required, and large-scale equipment is not only expensive, but also bulky. The power department did some tests to solve these problems. According to domestic and foreign tests, this product can solve this problem. Not only the size of the instrument is small, but the weight is greatly reduced. Precautions When carrying out 35KV cable test, one-phase test is strongly suggested. Voltage is set to 60KV (General Requirements)-78KV (according to the rules needed) and the frequency is set to 0.1Hz, 0.05Hz,0.02Hz and 0.01Hz. The manual said load capacity is the theoretical value, the scene 35KV cable length can reach 3-15 km. In case the cable is too short(less than 500 meters), the capacitance of the test object is smaller than 0.1 F and the pressure cannot be normally boosted, please connect 0.1 F high-voltage capacitance in parallel way. Keep high-voltage terminals nylon spin by the above numbers to the corresponding nylon seat, high-voltage lines to ensure good contact , no contact is good , it will cause a discharge , burned the high side . When nylon terminals tightened, pay attention to the intensity, excessive tightening may damage the nylon terminals. 80KV 0.1HZ VLF high voltage generator Model Rated Voltages Load capacity Fuse Weight Useful VLF-80 80kV (peak ) 25A
NCS-BP105 Fieldbus Power Conditioner NCS-BP105 Fieldbus Power Conditioner applies to Foundation Fieldbus and Profibus PA control system and provides power to fieldbus instrument. Fieldbus Power Conditioner adopt an active impedance control circuitï¼?prevents the conventional power supply from absorbing the Fieldbus signal otherwise interfering with the operation of the Fieldbus. Working with terminator together, it provides perfect bus signals. There are two LED for power indication and fault indication. Fieldbus Power Conditioner can support redundancy when two Power Conditioners work in redundancy mode in order to enhance the reliability of the system. NCS-BT105 Fieldbus Terminator NCS-BP105 Fieldbus Terminator mounted in two side of the bus, applies to Foundation Fielbus and Profibus PA control system in order to provide impedance matching and convert bus current to voltage.
Technical requirement: 1. The material is black ABS material 2. The appearance is smooth, no drape, damage, etc. 3. The injection mold should have the mold model 4. Input 3.3VDC, standby power 0.01W, working current 0.08mA 5. The sensing angle is 120°, and the sensing distance is 1~2m.
Product description The impulse voltage generator intelligent measurement and control system is the latest programmable control system and consists of two parts: Automatic control of pulse voltage generator program and automatic analysis of pulse signal measurement. The General Conditions of Use Altitude: 1000m Ambient temperature: 5 40 Relative humidity: 90 20 Use of the environment: indoor Non-conductive dust Grounding resistance 0.5 No fire or explosion hazard Earthquake resistance: 8 magnitude There is no gas that corrodes metal and insulates Impulse voltage generator (2) Supply voltage waveform is the actual sine wave, waveform distortion rate 85% (more than 90% when no load 300PF); (2)Truncated wave: cut-off time (2-6) 10% , zero-crossing coefficient 0.3% (3)Standard operating impulse voltage wave 250 20% s / 2500 60% s, The impulse voltage waveform parameters and their deviations are in line with the requirements of the national GB311 and GB16927 standards.
Overview Three-phase phase volt-ampere meter a high precision instrument for measurement of three-phase electric parameters, it can be used to measure the three phase voltage, current and phase angle, frequency, power, power factor and so on. three-phase digital volt-ampere phase meter adopt high-speed Cortex M3 processor and 24 bits high-speed ADC a for measuring and calculation , A complete graphical interface, true color display with resolution of 320 x 240 and touch screen operation make a friendly man-machine interface. It is easy to carry
Products Introduction Very Low Frequency high voltage generator 30KV combines advanced technologies such as modern digital conversion, full computer control, automatic voltage increase, voltage reduction, measurement and protection. In the automatic upgrade process, human intervention can be taken care of. The main advantages include full electronics, small size, light weight, large-screen LCD display (clear and intuitive), printer output test report, and easy use. Technical Parameter