Our oil-immersed power transformers have stable operation, high safety and efficiency, low price and wide application. Oil-immersed power transformers are integrated with production, sales and installation, with strong strength and good reputation. Our oil-immersed power transformers have stable operation, high safety and efficiency, low price and wide application. Oil-immersed power transformers are integrated with production, sales and installation, with strong strength and good
Power distribution transformer is one of the important equipments in power supply and distribution system of industrial and mining enterprises and civil buildings. Classification: 1.Power transformers are classified by use: boost (power plant 6.3kv / 10.5kv or 10.5kv /110kV, etc.), contact (220kV/110kV or 110kV/ 10.5kv between substations), voltage reduction (distribution 35kV/ 0.4kv or 10.5kv / 0.4kv). 2.Power transformers are classified by phase number: single phase, three phase. 3.Power transformers are classified by insulation media: oil-immersed transformers (flame retardant, non-flame retardant), dry transformers, 110kVSF6 gas insulated transformers. url:http://www.ybtransformer.com
Three phase current transformers Model: DASN240, DASN242, DASN248, DASN249, DASN250 Input current: 60-1600A Output: 5A /1 A Accuracy: 0.2/0.5/1.0
Bare Copper Electrical Wire Cable,Website:http://www.ybtransformer.com,Bare Conductor Wire
HEYI open core transformer KCT
Three phase current transformers D363: inner hole 3*30mm, Ratio: 50/5A, 75/5A, 100/5A, 150/5A, 200/5A, 250/5A, 300/5A, 400/5A, 500/5A D364: inner hole 3*41mm, Ratio: 300/5A, 400/5A, 500/5A, 600/5A
The KCT range of split core current transformers have been specifically designed to be small CT and easy to open and yet maintain the accuracy required for kwh meters. The benefit of a split core current transformer is that it can be placed into position easily and without disturbing or disconnecting the main cables it is monitoring. The KCT range of current transformers has two insulated terminal covers for connecting the S1 and S2 cables which lock down over the terminal screws fully insulating the connections. This makes it ideal to use Autometers cable hamesses which are colour coded and individually numbered on each conductor ensuring simple and easy connection from the current transformer to the electricity meter. Features: 1:The structure of the self-locking, safe, easy to install, portable 2:Wide inner window, allowing clamping of big cables or bus-bars 3:Wide range of sizes to accommodate all the existing installations 4:Isolated plastic case recognized according to UL94-V0 5:Wires plugs,Audio plugs,Power plugs and so on five kinds of plugs Applications: 1:Current measurement, monitoring and protection for electrical wiring and equipment. 2:Current and power measurement for electric motors, lighting, air compressor,heating and ventilation system, air-condition equipment and automation â?? control system. 3:Current, power and energy monitoring device. 4:Relay protection device. Model Guide: 1) KCT-6: inner hole size: 6mm, Ratio: 5A/2.5mA, 10A/5mA, 20A/10mA 2) KCT-10: inner hole size: 10mm, Ratio: 5A/2.5mA, 20A/10mA, 60A/20mA, 75A/25mA, 1~75A/0.333V 3) KCT-16: inner hole size: 16mm, Ratio: 100A/33.3mA, 100A/40mA,120A/40mA, 200A/66.7mA, 100~200A/0.333V 4) KCT-24: inner hole size: 24mm, Ratio: 100A/40mA, 200A/40mA, 200A/66.7mA, 400A/80mA, 100~400A/0.333V 5) KCT-36: inner hole size: 36mm, Ratio: 300A/100mA, 400A/40mA, 500A/50mA, 600A/60mA, 300~600A/0.333V
Split core Current transformer: 1) HK-23: Inner hole 20*30mm, Ratio: 100/5A, 150/5A, 200/5A, 250/5A, 300/5A, 400/5A 2) HK-58: Inner hole 50*80mm, Ratio: 250/5A, 300/5A, 400/5A, 500/5A, 600/5A, 750/5A, 800/5A, 1000/5A 3) HK-812: Inner hole 80*120mm, Ratio: 500/5A, 600/5A, 750/5A, 800/5A, 1000/5A, 1200/5A, 1250/5A, 1500/5A, 1600/5A, 2000/5A, 2500/5A, 3000/5A, 4000/5A 4) HK-816: Inner hole 80*160mm, Ratio: 1000/5A, 1200/5A, 1500/5A, 1600/5A, 2000/5A, 2500/5A, 3000/5A, 4000/5A, 5000/5A, 6000/5A, 7500/5A, 8000/5A
Veikongs softstarters increase a motor's lifetime by protecting it from electrical stresses. They do so by letting you optimize starting currents that with conventional starting methods put lots of stress on the motor. With many built-in motor protection features, your motor is â safe in its hands. Veikong's softstarters are also installation-friendly and can cut your assembly and startup time by being easy to use and easy to learn. With everything that you need in one unit, from bypass contactor to overload protection, a single softstarter makes for a compact and complete starting solution. Furthermore, with many application specific features, veikong's softstarters can ultimately help you increase productivity. Torque control, pump cleaning and many more features let you do more than simply softstarting. Main benefits 1, secure motor reliability 2, improve installation efficiency 3, increase application productivity. Main featuresâ 1, offering: pstx, pst(b), pse, psr and pss 2, veikong's softstarters cover any motor application from 3 a to 2160 a 3, reduced starting current and less electrical stress on the motor and the network 4, fast and easy to install and set-up with a small footprint 5, reduced mechanical wear and tear on mechanical equipment.
1, vector control and torpue control 2, high torque 200% output at 0.25hz 3, easy installation and commissioning
1, power reange 1xac 230v 0.4kw to 3xac 400v 630kw 2, use in hd(heavy duty)or nd(normal duty) mode 3, expandability through i/o and pg card 4, integrated operating panel for simple, fast commissioning
High output string inverter for home solar system Maximum efficiency 98.2% Real-time yet accurate mppt algorithm to ensure the maximum benefits Wide input voltage range from 250v to 960v Provides professional yet economical solutions for home solar power system Dc switch (optional for users to choose) Dc surge protector (optional) Ac surge protector (optional) Built-in photovoltaic pool (optional) Built-in energy management module Best string inverter choice for large-scale photovoltaic power plants, commercial buildings Convenient maintenance of low cost Easy installation with removable cover Rustproof aluminum cover Flexible and mature monitoring solution for solar home power system All kinds of string inverter information can be displayed by setting the multi-function relay Smart grid management Built-in lvrt function Reactive power adjustable function Automatical load reducer when over frequency Remote active power limit control function
Power Transformer (35kV) Oil-immersed Transformer Products structure and technical features The oil-immersed transformer produced by our factory have these advantages: low loss, low noise, high short circuit strength and good appearance. We company create these prefect products of that each parameter has reached to advanced level among domestic similar products by combining advanced manufacture equipments and technology. Structure features: Core and main body: it is used iron core cutting line ,all inclined ladder joints and improving flux trend to eliminate flux saturation phenomenon of iron core in joints . By doing these, it reduces the no-load loss, no-load current and noise of transformers. Adopting pulling-plank structure, in order to strengthen the ability of withstanding short-circuit, we put many nails around pressing planks and bracing plates are used as support between H.V and L.V yoke, make the iron core be a whole. The iron core sheet are coated by glue which are specialized for silicon steel , so that all silicon steels can be bonded together to make the iron core be  integral one, this effectively enhances mechanical strength and plays a positive role in the core anti-rust. The low part of the body and the oil tank are supported through bracing plates adopt" high intensity electric laminated" technology, to guarantee the low part of oil-immersed transformer's body safe and reliable. Coil: The high-voltage(HV) coil adopts an interleaved-continuous structure, The low-voltage(LV) coil adopts an interleaved-continuous or spiral structure, are independently provided with voltage-regulating winding to balance the ampere turn of each winding-up, effectively lower the mechanical force to minimal level. In the transformer winding, there is a zigzag oil guide structure so as to fully cool all areas inside the winding, lower the temperature rise of the winding and the hot points of the winding and prolong the service life of insulation. Oil tank: the tank's structure of oil-immersed transformer is bell jar type or suspended type, have a good looking and high mechanical strength. It adopts" flanged joint" technology in every key point (such as annular tubes, pressure valves, switches,etc.), which effectively avoid leaking oil. Technical Parameter and features Technical specification 1,voltage:35kV 2,voltage regulation: on load tap regulation ,off circuit tap regulation 3,capacity range:
Rated Input Current:2mA Rated Output Current:2mA Turns ratio:1000:1 Phase Angle Error:less than 45'(2mA,50) Linear Range:0~1000V 0~10mA(50) Mounting(mm):PCB
Rated Input Current:5A Rated Output Current:2.5mA Turns ratio:2000:1 Phase Angle Error:less than 20'(1A,100) Linear Range:0~20A(100) Mounting(mm):D5.0 * Small size * High accuracy * Good consistency * Used for current and power measurement
Advantages of toroidal transformers 1. High efficiency and high performance price ratio Toroidal core has good electromagnetic performance, like high saturation magnetic flux density, high primary inductance and large unit magnetizing power capacity, which improve the utilization ratio of the core and the winding window area, and reduce the number of turns and the direct current resistance, and also greatly improve the overload capacity and load efficiency of the toroidal transformer. Based on these conditions, the product design does not need to consider more power margin and heat dissipation conditions, and also effectively control the cost. 2. Excellent no-load characteristics Toroidal core is wound with high permeability silicon steels, no gap on magnetic circuit, low magnetic resistance. Under the same power and magnetic field density, the no-load loss and exciting current of toroidal transformer are only 50%~70% of other transformers, which reduce the standby loss and improve the equipment operation reliability. 3. Low noise There is no gap of toroidal core, the silicon steels are tightly winded, and after the vacuum impregnation with pressure it becomes a whole. Even in the middle, high magnetic frequency, it will not cause noise due to magnetic expansion. This is what the EI, dry-type and other lamination cores cannot match. 4. Low magnetic flux leakage, low leakage inductance Toroidal core has a high saturation flux density, and the coil is uniformly distributed on the core, magnetic potential difference can effectively reduce the magnetic leakage. Normally, with the same transformer specifications, the magnetic flux leakage of toroidal transformer is only 1/10 of the EI one. The main coil is tightly and rationally layered winded, and then the leakage inductance of the primary and secondary coils can be better coupled to reduce the primary and secondary leakage inductance. 5. Safety of electrical structure There is a certain thickness of stacked dielectric film between the core and primary coils, primary coil and electrostatic shielding, electrostatic shielding and secondary coil, secondary coil and the installation plate, which completely isolates the electrical gap and is safe without maintenance. Therefore, isolated toroidal transformers have been widely used in medical equipment transformers.
Your search for three-phase transformer manufacturers ends at trutech products. Our offered transformer is the perfect example of technology and modernity. To search out more details about the product and price range of each unit, be in touch with us.