Three phase current transformers
Model: DASN240, DASN242, DASN248, DASN249, DASN250
Input current: 60-1600A
Output: 5A /1 A
Accuracy: 0.2/0.5/1.0
DASN series three phase current transformer development of DAS series,use it in primary current 60A-1600A electric circuit , Supporting the use of plastic shell breaker.
Epoxy Potting,Double-screw fastening,safe,easy to install,portable. Wide inner window,allowing clamping of big cables or bus-bars. Wide range of sizes to accommodate all the existing installations. Conforms to IEC185,BS7626,BSEN60044-1 and IEC60044-1.
Epoxy Potting,Double-screw fastening,safe,easy to install,portable. Wide inner window,allowing clamping of big cables or bus-bars. Wide range of sizes to accommodate all the existing installations. Conforms to IEC185,BS7626,BSEN60044-1 and IEC60044-1.
Supplier: Tarpaulin, tarp, pe tarp, frp, grp, grating, pultruded, composite, frp rebar, panel tanks, pond liner, geomembrane, junction box, truck cover, boat cover, tent, camping, current transformers, indoor current transformers, outdoor transformers, switch gears, oil filled tank type transformers, wound primary type transformers, bar type transformers, window type transformers
D363 & D364 range of current transformers are combination designed 3 CT in 1, save more space comparing general unit CT, suitable for primarycurrent 75A to 600A, supporting the use of molded case circuit breaker according to the rated current size.
Supplier: Japanese quality switchgear components, breakers, magnetic contactors, switches, pilot lights, pushbuttons, panel instrumentations, power management meter, protection relays, transformers, inverters, ups.
PION range of low voltage transformers comprise of double wound and custom designed transformers. PION transformers are available in open enclosed, oil cooled models to suit the customer requirement. Air cooled transformers are available in Open and Enclosed models. The enclosed models are supplied in sheet steel enclosures. Louvering is provided for the heat dissipation of the generated heat. Oil cooled transformers are housed in MS Tank and provided with adequate pressed steel radiators to ensure proper heat dissipation Oil cooled units are available with standard accessories viz. oil level indicator, drain plug / drain valve, earth terminals, unidirectional CI wheels, Oil fill hole and terminal covers.
Place of Origin: Beijing, China (Mainland) Brand Name: HYLITON POWER Model Number: LXZ250250180060 Usage: Current Phase: Single Coil Structure: Toroidal Coil Number: Autotransformer Rated frequency: 50Hz or 60Hz Rated secondary current: 5A or 1A Rated short-time thermal current: 40kA,1s Rated continuous thermal current: 120%In Continuous power-frequency voltage: 3kV , 1min Instrument security factor: FSâ?¤10 Application condition Ambient temperature -25-+40 Average temperature of day â?¤40 Altitude â?¤3000m Pollution class III Technical data Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA,1s Rated continuous thermal current 120%In Continuous power-frequency voltage 3kV , 1min Instrument security factor FSâ?¤10
S13 series of Three-phase oil Immersed Transformers,three phase transformer,three phase variable transformer,3 phase transformer,three phase power transformer,3 phase step down transformer Oil Immersed Transformer Model and Meaning Model No. Rated CapacityKVA Rated Voltage KV Connection Group Symbol Loss W No-load Current (%) Impedance Voltage% High Voltage KV Tapping Range of High Voltage Low VoltageKV No-load On Load S13-M*R-30/10 30 10 ±5%±2x2.5% 0.4 Dyn11Yyn0 80 630/600 0.30 4.0 S13-M*R-50/10 50 100 910/870 0.24 S13-M*R-80/10 80 130 1310/1250 0.22 S13-M*R-100/10 100 150 1580/1500 0.21 S13-M*R-160/10 160 200 2310/2200 0.19 S13-M*R-200/10 200 240 2730/2600 0.18 S13-M*R-250/10 250 290 3200/3050 0.17 S13-M*R-315/10 315 340 3830/3650 0.16 S13-M*R-400/10 400 410 4520/4300 0.16 S13-M*R-500/10 500 480 5410/5100 0.16 S13-M*R-630/10 630 570 6200 0.15 4.5 S13-M*R-800/10 800 700 7500 0.15 S13-M*R-1000/10 1000 830 10300 0.14 S13-M*R-1250/10 1250 970 12000 0.13 S13-M*R-1600/10 1600 1170 14500 0.13 Notes: The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents. We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.