The impulse voltage generator intelligent measurement and control system is the latest programmable control system and consists of two parts:
Automatic control of pulse voltage generator program and automatic analysis of pulse signal measurement.
The General Conditions of Use
Altitude: 1000m
Ambient temperature: -5 40 Relative humidity: 90 20 Use of the environment: indoor
Non-conductive dust Grounding resistance 0.5 No fire or explosion hazard
Earthquake resistance: 8 magnitude There is no gas that corrodes metal and insulates
Impulse voltage generator (2)
Supply voltage waveform is the actual sine wave, waveform distortion rate 85% (more than 90% when no load 300PF);
(2)Truncated wave: cut-off time (2-6) 10% s, zero-crossing coefficient 0.3%
(3)Standard operating impulse voltage wave 250 20% s / 2500 60% s,
The impulse voltage waveform parameters and their deviations are in line with the requirements of the national GB311 and GB16927 standards.
7, the lowest output voltage is greater than 10% of the nominal voltage
8. Duration of use: Above 70% of rated voltage, it can be continuously operated every 120 seconds after charging and discharging. It can be continuously operated after charging and discharging every 60 seconds under 70% of rated voltage.
One computer is used for control and waveform analysis 18-inch LCD monitor, strong anti-interference and long life
WINDOWS XP, OFFICE 2003, LabVIEW related driver software, ACE measurement and control software package,built in
Ultra-low frequency dielectric strength testing is another method of power frequency withstand voltage testing, because large-capacity testing is required, and large-scale equipment is not only expensive, but also bulky. The power department did some tests to solve these problems. According to domestic and foreign tests, this product can solve this problem. Not only the size of the instrument is small, but the weight is greatly reduced.
Precautions
When carrying out 35KV cable test, one-phase test is strongly suggested. Voltage is set to 60KV (General Requirements)-78KV (according to the rules needed) and the frequency is set to 0.1Hz, 0.05Hz,0.02Hz and 0.01Hz. The manual said load capacity is the theoretical value, the scene 35KV cable length can reach 3-15 km.
In case the cable is too short(less than 500 meters), the capacitance of the test object is smaller than 0.1 F and the pressure cannot be normally boosted, please connect 0.1 F high-voltage capacitance in parallel way.
Keep high-voltage terminals nylon spin by the above numbers to the corresponding nylon seat, high-voltage lines to ensure good contact , no contact is good , it will cause a discharge , burned the high side . When nylon terminals tightened, pay attention to the intensity, excessive tightening may damage the nylon terminals.
NCS-BP105 Fieldbus Power Conditioner
NCS-BP105 Fieldbus Power Conditioner applies to Foundation Fieldbus and Profibus PA control system and provides power to fieldbus instrument. Fieldbus Power Conditioner adopt an active impedance control circuitï¼?prevents the conventional power supply from absorbing the Fieldbus signal otherwise interfering with the operation of the Fieldbus. Working with terminator together, it provides perfect bus signals. There are two LED for power indication and fault indication. Fieldbus Power Conditioner can support redundancy when two Power Conditioners work in redundancy mode in order to enhance the reliability of the system.
NCS-BT105 Fieldbus Terminator
NCS-BP105 Fieldbus Terminator mounted in two side of the bus, applies to Foundation Fielbus and Profibus PA control system in order to provide impedance matching and convert bus current to voltage.
Technical requirement:
1. The material is black ABS material
2. The appearance is smooth, no drape, damage, etc.
3. The injection mold should have the mold model
4. Input 3.3VDC, standby power 0.01W, working current 0.08mA
5. The sensing angle is 120°, and the sensing distance is 1~2m.
Overview
Three-phase phase volt-ampere meter a high precision instrument for measurement of three-phase electric parameters, it can be used to measure the three phase voltage, current and phase angle, frequency, power, power factor and so on.
three-phase digital volt-ampere phase meter adopt high-speed Cortex M3 processor and 24 bits high-speed ADC a for measuring and calculation , A complete graphical interface, true color display with resolution of 320 x 240 and touch screen operation make a friendly man-machine interface. It is easy to carry
Very Low Frequency high voltage generator 30KV combines advanced technologies such as modern digital conversion, full computer control, automatic voltage increase, voltage reduction, measurement and protection. In the automatic upgrade process, human intervention can be taken care of. The main advantages include full electronics, small size, light weight, large-screen LCD display (clear and intuitive), printer output test report, and easy use.
This test bench can be widely used in measurement centers of start grid, management and electric energy measuring departments of power supply companies, national measurement laboratories, as well as large industrial and mining enterprises and electric meter manufacturers.
HS-3303M is a three-phase electric energy meter inspection device designed based on the requirements of the IR46 metering part, which meets the harmonic requirements of the IR46 electric energy meter. It can output square wave, peak wave, current multiple zero-crossing wave, higher harmonics, odd harmonics, sub-harmonics, custom harmonics, etc.
This device is equipped with 3 epitopes and has a small structure, which is suitable for product research and development, model selection, random inspection, etc.
For more product details,please see Energy Meter Test Bench this page :
The 5 blades horizontal axis wind turbine has a smart blade aerodynamics braking and electromagnetic speed limitation function. Patented aerofoil 5 blades design with true symmetrical and twisted aerodynamic feature which ensures rotor capture maximum power from wind and operates in amazingly low noise and minimal vibration. True symmetrical and balanced aerofoil blade ensure rotor matching with generator perfectly. Large ratio of tip section chord to root section chord and variable chord airfoil blade ensures rotor start-up easily and running smoothly with high torque and RPM at lower wind condition. Aerodynamic blades designed with over-speed braking system to make sure generator well protected in higher wind. Reinforced Glass-Fiber Nylon is using advanced thermoplastic engineering and precision injection molding technology for higher strength, flexibility and reliability. Our wind turbine with minimal vibration and low noise could be mounted on rooftop safely and its operation wonâ??t affect resident.
YE800 Mobile electric dosing metering oil system
YE800 Technical data:
Oil control gun:1pcs
Electric pump:220VAC,50HZ
Flow rate:10-18LPM(Liter/Min)
Preset scope:1-999.9L
Accuracy: 1%;
High pressure oil hose:4M
Its very suitable for factory working line ,workstations and it can preset liters which you want to dispens automatic.
VLF high voltage generator 60KV.The capacity of it is 1/500 of tradition way. Greatly simplify testing procedures, That is why commonly used in the developed , s ministry of electric power entrust Wuhan high voltage research institute to drafting 35Kv and below XLPE insulated power cable ultra-low frequency (0.1Hz) voltage withstand test methods for promoting this approach. The instrument is developed according to made of this need. It can be widely used in cable, large-scale high-pressure rotary motor, power capacitors into AC voltage withstand test.
Power capacitance of single-core XLPE insulated cable (F/km)
0.1Hz -60KV Ultra-Low Frequency High Voltage Generator