Please click here to check who's online and chat with them.

Find Verified Electric Circuit Breakers Suppliers, Manufacturers and Wholesalers

Oct-15-19
 
Jovean&Rogy electrical is the specialized manufacturer of modular electric terminal devices for household and similar installations.
We selling MCB,RCBO,RCCB,Switch-disconnector,Distribution Box etc.Ourproduct passed lab.test and obtained safety approvals:CE(Europe),S(SEMKO Sweden),B(Poland),CCC(China),CB,TUV(Germany),DVE(Germany),KEMAEUR(Netheland),UL(USA),IRAM(Argentina)
contact with me for more information .
YongYi Zheng,
zhengyy(at)rogy(dot)cn
Thanks
Oct-11-19
 
Provide Miniature Circuit Breaker, contact zhengyy@rogy.cn for more information.

Pole No:1,1P+N,2,3,3P+N,4
Rated voltage:AC 230/400V
Rated current(A):
1,2,3,4,6,10,13,16,20,25,32,40,50,63
Jul-11-19
 
MCB has the characteristics of advanced structure, reliable performance, high breaking capacity and beautiful appearance. It is mainly used for AC 50HZ or 60HZ, rated voltage 400V or below and rated working current 63A or below. It is used for overload and short-circuit protection of lighting, distribution lines, equipment in office buildings, residential buildings and etc. It can also be used for infrequent on-off operations and conversion of lines.
Jul-09-19
 
Mini hydraulics electromagnetic AC DC Toggle Type Circuit Breaker for Equipment Electrical Panel Control trip free 1-50A
May-31-19
 
miniature circuit breaker lockout with aluminum:
1.suitable for MCB;
2.0.5g/PC;
3.100PCS/box;

info@new-pv.com
www.new-pv.com
1113 Electric Circuit Breakers Suppliers
Short on time? Let Electric Circuit Breakers sellers contact you.
May-31-19
 
MCB enclose waterprrof box:
1.4P or 8P;
2.Material:PC or ABS;
3.IP66;
4.With MCB or without MCB.

info@new-pv.com
http://www.new-pv.com/products_show.asp?id=220
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 6kA
Leakage protection trip type: Electronic /Electromagnetic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life : 4000 Times
Type of residual current: A/AC
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity (Icn): 10kA
Rated working current (In): 1-63A
Rated working voltage( Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Time
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A (can be extended to 125A)
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current : A/AC
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity( Icn): 6kA
Release Type of Leakage Protection: Electronic
Rated working current In: 6-40A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life :4000 Times
Residual current type: A/AC
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity (Icn): 6kA
Rated working current (In): 1-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Times
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 6kA
Leakage protection trip type: Electronic /Electromagnetic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Type of residual current : A/AC
May-23-19
 
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity (Icn): 6kA
Rated working current (In): 1-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Times
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N/3P+N
Rated short circuit breaking capacity (Icn): 6kA
Leakage protection trip type: Electronic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Type of residual current: A/AC
May-23-19
 
Standard: EC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity (Icn): 4.5/6kA
Rated working current: In 1-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Times
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 4.5kA
Release Type of Leakage Protection: Electronic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Residual current type: A/AC
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity( Icn): 10kA
Rated working current (In): 1-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Times
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 10kA
Release Type of Leakage Protection: Electronic /Electromagnetic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Residual current type: A/AC
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 6kA
Release Type of Leakage Protection: Electronic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Residual current type: A/AC
1113 Electric Circuit Breakers Suppliers