Find Verified Electric Circuit Breakers Suppliers, Manufacturers and Wholesalers

Jul-09-19
 
Mini hydraulics electromagnetic AC DC Toggle Type Circuit Breaker for Equipment Electrical Panel Control trip free 1-50A
May-31-19
 
miniature circuit breaker lockout with aluminum:
1.suitable for MCB;
2.0.5g/PC;
3.100PCS/box;

info@new-pv.com
www.new-pv.com
May-31-19
 
MCB enclose waterprrof box:
1.4P or 8P;
2.Material:PC or ABS;
3.IP66;
4.With MCB or without MCB.

info@new-pv.com
http://www.new-pv.com/products_show.asp?id=220
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 6kA
Leakage protection trip type: Electronic /Electromagnetic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life : 4000 Times
Type of residual current: A/AC
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity (Icn): 10kA
Rated working current (In): 1-63A
Rated working voltage( Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Time
1109 Electric Circuit Breakers Suppliers
Short on time? Let Electric Circuit Breakers sellers contact you.
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A (can be extended to 125A)
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current : A/AC
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity( Icn): 6kA
Release Type of Leakage Protection: Electronic
Rated working current In: 6-40A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life :4000 Times
Residual current type: A/AC
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity (Icn): 6kA
Rated working current (In): 1-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Times
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 6kA
Leakage protection trip type: Electronic /Electromagnetic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Type of residual current : A/AC
May-23-19
 
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity (Icn): 6kA
Rated working current (In): 1-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Times
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N/3P+N
Rated short circuit breaking capacity (Icn): 6kA
Leakage protection trip type: Electronic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Type of residual current: A/AC
May-23-19
 
Standard: EC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity (Icn): 4.5/6kA
Rated working current: In 1-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Times
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 4.5kA
Release Type of Leakage Protection: Electronic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Residual current type: A/AC
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity( Icn): 10kA
Rated working current (In): 1-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Times
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 10kA
Release Type of Leakage Protection: Electronic /Electromagnetic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Residual current type: A/AC
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 6kA
Release Type of Leakage Protection: Electronic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Residual current type: A/AC
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity Icn: 4.5kA
Release Type of Leakage Protection: Electronic
Rated working current (In): 6-32A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Residual current type: A/AC
May-23-19
 
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N/3P+N
Rated short circuit breaking capacity (Icn): 6kA
Leakage protection trip type: Electronic
Rated working current (In): 6-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Type of residual current : A/AC
1109 Electric Circuit Breakers Suppliers