ST Series of wall mounting metal cabinet Features: 1) Construction: A) Body and door manufactured in 1. 5mm sheet steel. B) Flat mounting plate in 2. 5mm sheet steel 2) Finish A) Case and door RAL 7032 textured finish B) Mounting plate in RAL 2004 smooth finish 3) Protection degree: IP65 to EN60 529 NEMA 4
Dz47-63(c45n) series circuit breaker is used in lighting distribution system or motor distribution system for protecting overload and short circuit in the system. This circuit breaker is neoteric in structure, light in weight, reliable and excellent in performance. Its frame and parts adopt plastics of high fire resistant and shockproof. The product, with long life, is mainly used in ac 50hz/60hz single pole 240v or two, three, four poles up to 415v circuit for overload and short circuit protection, as well as for unfrequently switching on&off electric equipment and lighting circuit in normal case. The products comply with iec 60898 & gb10963-1999. Specification: Number of pole: 1, 2, 3, 4pole Rated voltage: 240/415ac Rated current: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63a Breaking capacity: 4.5/6ka Electrical endurance: 10, 000 times
Model numbe:yeq2y(integral type)series Automatic transfer switches yeq2y 63-800a series integral type Ie:10a~800a Poles: 3p/4p Connection:utility - utility or utility - gen, Yeq2 dual-power supply automatic transfer switch is made up of the mechanism And the automatic controller, the body of unit is made up of singe electromotor operating Mechanism, the yeq2 seires circuit breaker , internal accessories (auxiliary contact, alarm contact)motherboard and terminal block. The automatic controller is divided into ensemble and separate, separate, the controller is mounted on the chest, and the cupboard door, the other components are mounted on the mental motherboard (the motherboard has the sockets of the terminal block);ensemble:the single electromotor operating mechanisms , the automatic controller, and the circuit breaker are all mounted on the motherboard, and the structure is compact. What does a transfer switch do, and why do i need one? A transfer switch is the link between your backup generator, the utility company, and Your home or business. It's job is to safely connect your home or business to Your backup generator during a power outage. A properly installed transfer switch Will isolate your generator from the utility company's power lines, protecting The power companies workers from harm. A transfer switch is required by law in All 50 states, and is an essential piece of safety equipment. 1) applicable to automatic transfer for main power supply and reserve supply of feed system or automatic transfer and security isolation of two load equipment 2) integrates switch with logic control as a whole, if without logic control, an additional controller is provided 3) realize selected mechanical integration possessing of voltage inspection, communication interface, electric and mechanical interlock 4) can actualize automatic, electric long range and emergency manual control
Model number: yeq2c Detailed product description Yeq2 series intelligent dual power automatic switch two or three poles and four pole mccb annex (supplementary the police contact), the mechanical interlocking transmission, intelligent controller and other components. It has the integral style and split type two kinds mechanism. Integral controller is equipped with a base and executing agencies; split type is intelligent controller installed in the panel , installed user base by implementing agencies to install the counter body controller with the implementing agencies with about 2m long cables. The body of the intelligent system consists of such accessories as dedicated positive/negative electromotor, breaker, fire control tripping, mechanical interlocking, aviation plug and connector terminal. All components are installed on the same metal sheet. The intelligent system (400vac 50/60hz working voltage) is provided with the function of mechanical-electrical interlock protection to guarantee safe and reliable power supply for you. Functions:1. The automatic controller can measure the voltages of both circuits at the same Time. When the supply voltage is higher than 115% of the rated value, it judges As over voltage; when it is lower than 60% ~ 80% (preset by user) of the rated voltage, It judges as under voltage. The microcomputer judges and processes the measuring Results and then sends out corresponding orders as switch-off, switch-on, generation, Unloading and alarming.
Model number: yeq2f (split type) Automatic transfer switches - function: power automatic transfer and overload and short circuit protection - performance: the time delay of transfer time is adjustable and action time is accurate - usage: mainly used in the two-path load field as in hospital, shopping center, Bank, and chemical industry, metallurgy and military facilities - structure: compact in structure, small in volume, high breaking and short arcing - current: 10a~800a - frame current: 63, 100, 225, 400, 630, 800 number of pole: 3p, 4 p - standards: comply with iec 947-6 What's the difference between a manual transfer switch and an automatic unit? with a manual transfer switch, when the power goes out, you need to start your generator, and connect it to the transfer switch. You then need to switch your house over to generator power. When the utility power is restored you need to switch your house back to utility power, and turn off your generator. With an automatic transfer switch, everything is fully automatic. When the utility power goes out, the transfer switch signals your generator to start. Once the generator is running the transfer switch automatically connects your home or business to the generator. When the utility power is restored, the transfer switch reconnects your home or business to the utility. Then it turns off your generator and waits patiently for the next power outage.
Model number:yes1-32c Automatic transfer switches Model:yes1-n/yes1-c Current:16a~32a Pole:2p, 3p, 4p Yes1 is suitable for transferring between two circuits of power supply(main power supply, emergency power supply) in ac 50hz, rated working voltage to 220v and rating current up to 16a~32 a, Function:over voltage, under voltage, lost phase, utility to utility Utility to generator(with a passive contact sent a signal to start or shut off the generator) Attention: it must not do the test of insulating stand voltage for the quality guarantee.
SG2008 Automatic 12kV Capacitance & Dissipation Factor Test Set is designed to measure dissipation (Dielectric Loss Angle tgª-) or power factor (cosª+) in heavy electromagnetic interference environment such as in power plants or substations. Also it can be used in laboratory for high accurate test. The test set is all-in-one structure: including precision digital bridge, 12kV/200mA frequency conversion power unit, reference capacitor (CN), and other electronic circuits. An external power supply can expand the test range. True portability is realized by the lightweight. Simple usage is realized by the full automation. High performance is realized by the digital process. We can also provide the professional solutions and equipments for: withstanding voltage testing, c & tan-delta (power factor) testing, partial discharge (PD) testing and impulse voltage testing.
As a upgrade var compensator for substations, the svqr has remarkable advanteges in many aspects such as var compensation precision, , response speed, stabilization of system voltage, reduction of line losses, and enhancement of transmission capacity. Senbao developed, for the first time in china, the substation var compensator, svqr, whose output is changed by regulating voltage across the capacitor. The svqr has found wide applications in substations. With complete hv and lv testing beds and the-state-of-the-art dsp-based control system development system, senbao has gathered a large army of excellent professionls and has passed the national iso 9001 quality system certification. The svqr is widely applied not only for new substations, but also for upgrading of existing substations, transforming the existing manual 1-step tbb into an automatic 9-step voltage-regulating-type var compensator. Senbao svqr has been operating successfully at an altude of 4, 000 meters in the cold area of shangri-la, yunnan, way ahead of the domestic manufacturers of the like products.
òConstructed of super nylon. òIn front of the lockout,90¦curved mental hook sets on left and right respectively, used for plug in the two holes of power switch. òUsed for open circuit breaker or closed circuit breaker.
GSB2 series Micro Circuit Breakers comply with IEC60898-1: Rated Isolation Voltage: up to AC500V Rated Voltage: 240V AC for 1P 415V AC for 2P, 3P and 4P Rated Current of Frame (A): 63A Rated Current (A): 1A, 3A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A Rated Ultimate Short-circuit Breaking Capacity (KA): 6 Rated Impulse Withstand Voltage or Uimp (KV): 4 Instantaneous Release: C or D Mechanical Life: 20000 times Grade of Protection: IP20 Connection Capacity: 1-25MM2 Frequency: 50Hz or 60Hz Poles: 1, 2, 3 or 4. Width of single pole: 18mm.
DZ47-63 Series High Breaking Capacity Mini Breaker may be used in such occasions with AC 50 or 60Hz, rated working voltage of 415V or below and rated working current of 63A.It can servefor the illumination of office, residential housing and similar buildings and its distribution wires and protect the distribution circuit and equipment against overload and short-circuit.It can also be used for infrequent conversion of circuit under normal conditions. Rated current:1A, 3A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A Number of poles:1p, 2p, 3p, 4p Working voltage:From 240V to 415V DZ47LE Series Leakage Circuit Breaker may be used in the circuit with AC 50 or 60Hz, rated voltage of 230V or 400V and rated current of 63A or below. It can prevent personnel from electric shock, protect equipment against leakage and the circuit against overload and short-circuit It can also serve as infrequent conversion of circuit and infrequent startup operation of motor under normal conditions. Number of poles: 1p+n, 2p, 3p, 3p+n, 4p, Working voltage: 240V, 380/400V, 240V, 240/415V Rated current: 1A, 3A, 6A, 10A, 20A, 25A, 32A, 40A, 50A, 63A DZ20 series Moulded Case Circuit Breaker (hereafter refers to as circuit breaker) to be suitable to exchanges 50HZ. The nominal current from 16A to 1250A, fixed insulation voltage 660V, fixed working voltage 380V (400V) and in the below electric circuit makes the infrequent transformation and the electric motor infrequent starting using of. The circuit breaker has the overload, short-circuits and owes the voltage protective device, can protect the line and the power equipment is not damaged. This circuit breaker may be vertical the installment (namely vertical stroke to install), also may the level installment (namely horizontal attire). This circuit breaker carries out the standard: GB14048. 2 and IEC60947-2. Product model: Dz20-100, dz20-225, dz20-400, dz20-630, dz20-800, dz20-1250 Rated current: From 16A to 1250A Rated working voltage: 380V DZ30LE-32 Leakage Protector may be used in single-phase domicile circuit with AC 50 Hz or 60Hz, rated voltage of 220 V and rated current of 32 A. It can prevent personnel from electric shock, and protect vivil electric lines against overload and short-circuit. This product is of such characteristics as small volume, high breaking capacity and cutting off the live and zero lines at the same time. Rated current: 3A, 6A, 10A, 16A, 20A, 25A, 32A Number of poles: 1p+n Working voltage: 220V
Mini circuit breaker has novel structure , reliable performance, high breaking capacity, pleasing outlook and small size. Its case and items are adopted by high fireresistant and shockproof plastics, it mainly used in the building office, house and similar building for illuminating at ac 50hz(60 hz), rated voltage below 400v , rated current below 100 a, distribution circuit and equipment overload, short circuit protection .It can also be used for unfrequent switch over of the circuit under normal conditions .This product conforms to the requirement of iec 60898&gb 10963 standards.
Mini circuit breaker has novel structure , reliable performance, high breaking capacity, pleasing outlook and small size. Its case and items are adopted by high fireresistant and shockproof plastics, it mainly used in the building office, house and similar building for illuminating at ac 50hz(60 hz), rated voltage below 400v , rated current below 100 a, distribution circuit and equipment overload, short circuit protection .It can also be used for unfrequent switch over of the circuit under normal conditions .This product conforms to the requirement of iec 60898&gb 10963 standards.
Mini circuit breaker has novel structure , reliable performance, high breaking capacity, pleasing outlook and small size. Its case and items are adopted by high fireresistant and shockproof plastics, it mainly used in the building office, house and similar building for illuminating at ac 50hz(60 hz), rated voltage below 400v , rated current below 100 a, distribution circuit and equipment overload, short circuit protection .It can also be used for unfrequent switch over of the circuit under normal conditions .This product conforms to the requirement of iec 60898&gb 10963 standards.
Mini circuit breaker has novel structure , reliable performance, high breaking capacity, pleasing outlook and small size. Its case and items are adopted by high fireresistant and shockproof plastics, it mainly used in the building office, house and similar building for illuminating at ac 50hz(60 hz), rated voltage below 400v , rated current below 100 a, distribution circuit and equipment overload, short circuit protection .It can also be used for unfrequent switch over of the circuit under normal conditions .This product conforms to the requirement of iec 60898&gb 10963 standards.
Product Description Major Technical Data: Rated voltage: 12KV Rated frequency: 50HZ Rated current: 630A. 1250A. 1600A. 2000A. 2500A. 3150A. 4000A. 5000A. Rated short circuit current to be turn-off: 20KA. 31. 5KA. 40KA. 63KA. Mechanical lifetime of the operating device: í¦100, 000 times (5000A 63KA Mechanical lifetime: í¦60, 000 times) Mechanical lifetime: (630A-1250A) 20KA í¦50, 000 times. (1250A-3150A) 31. 5KA í¦50, 000 times (1250A-4000A) 40KA í¦30, 000 times (5000A) 63KA í¦30, 000 times Operating voltage for switch-on and switch-off: DC220V or AC220V. Model: ZN73A-12 Standard: ISO9001 CQC CCC.
DZ47-63 Miniature Circuit Breakers has small size, light weight, novel structure and excellent performance. The material of enclosure and inside plastically parts is fire resistance and withstand shocking. It is used in the circuit of 50/60Hz,rated voltage 230/400 V, rated current up to 100A as protection against overload and short circuit. It is also used as protection against frequent switchover.
Mini circuit breaker, RCCB, ELCB, RCBO, RCD Mini current circuit breakers are used for protection against indirect touching of parts under voltage, for prevention of lasting voltage on earthed parts which should appear because of a defect in the electrical installation and for protection against direct contacts of parts under voltage in case of in
Molded case circuit breaker is one of the most advanced type breakers in the world, which adopt international advanced design and manufacture technology. The molded case circuit breakers are suitable for the circuit of ac 50/60hz, rated operating voltage up to ac 660v, dc 250v, rated operating current 10-800a. It is for distributing energy of electricity and infrequent switchover in normal conditions. They are provided the functions of the protection against overload, short circuit and under-voltage. The mccb complies with standard of iec60947-2. Carton package
Vacuum circuit breaker serves in the power system of 10kv and three-phase ac 50hz to function as switching different kinds of loads needing frequent operation, and can protect and control electric equipment in the industrial & mineral enterprise, power plant and substation as well. It can coordinate with the kyn28a-12(gzs1) middle-arranged manual-driven switchgear or xgn- stantionary switchger as well. Main technical parameter: Rated voltage 12kv Rated current 630~3150a Rated short-circuit breaking current 20~40ka Rated peak withstand current 50~100ka Rated short-time withstand current 20~40ka Rated duration short-time 4s Machanical endurance 20000 times Carton package