SG2008 Automatic 12kV Capacitance & Dissipation Factor Test Set is designed to measure dissipation (Dielectric Loss Angle tgª-) or power factor (cosª+) in heavy electromagnetic interference environment such as in power plants or substations. Also it can be used in laboratory for high accurate test. The test set is all-in-one structure: including precision digital bridge, 12kV/200mA frequency conversion power unit, reference capacitor (CN), and other electronic circuits. An external power supply can expand the test range. True portability is realized by the lightweight. Simple usage is realized by the full automation. High performance is realized by the digital process.
We can also provide the professional solutions and equipments for: withstanding voltage testing, c & tan-delta (power factor) testing, partial discharge (PD) testing and impulse voltage testing.
This is the most advanced automatic version of the c&df sets within our product range. The automatic 12kv 200ma test set integrates the high voltage power source and the measuring bridge into one single compact unit. It is designed to measure dissipation factor and capacitance in heavy electromagnetic interference environment such as in power plants and substations. Using digital filters it eliminates interference signal to specimen signal by a ratio as high as 2:1. It can also be used in laboratory for high accuracy tests on high voltage bushings, transformer windings, shunt reactors, current transformer, capacitor voltage transformer (cvt), grading capacitors of circuit breakers, surge arrestors and generator windings. Dissipation factor range v no limit Df resolution v 0.001% (1 x 10-5) Df accuracy v 1% + 4 digits Capacitance range v 3pf to 50000pf @ 12kv 60pf to 1uf @ 0.5kv Capacitance range accuracy v 1% + 1 digit Test voltage range v 0.5kv to 12kv, 200ma(max) Test voltage resolution v 1v Test voltage accuracy v 1% + 10 digits Input current range v 10ua to 5a Test time v 30s typical Cvt test mode v o/p voltage 3 to 50v, o/p current 3 to 30a Internal hv frequency v 45, 50, 55, 60, 65 hz (single) 45/55hz, 55/65hz (auto multiple frequency measure & avg for interference suppression) Input supply v 1-phase 220v 50hz, +/- 10% (flat pin type, type g electrical plug) Printer v thermal printer Communication port v rs-232. Moq - 1 pc Weight - 35 kgs Dimensions - 45cms x 35cms x 35cms.
Suitable for measuring C & Tan Delta for generators, transformers, bushings, circuit breakers, cables, motors at various test voltages up to 12KV Automatic C & Tan Test Set includes - Bridge Model MLS11DA - HV Supply model HLS12A - Laptop based & necessary cables - User friendly Visual C++ windows based Software.
Decade Resistance Box are precision instruments intended for general laboratory use, R&D and educational purposes. These are used as a multiplier, shunt, substitution resistor, or as an arm for AC or DC bridges. Specifications Metal Film Resistor Accuracy 1% Power Rating 1Wat Maximum Working Voltage 500 Volts.
1) Round type ABS compression sealed case with cap 2) Quick connects combined with cable termination 3) Moisture resistance, high strength, insulation and vibration 4) Applicable to 50 / 60Hz Single Phase AC motors 5) Lowing prices and best quality for long life 6) Bleeder resistor and bracket are available if required 7) Rated frequency: 50 / 60Hz 8) Rated voltage: 275 / 320V AC 9) Rated capacitance: 40 - 200MFD 10) Capacitance tolerance: 0 / +20% 11) Temperature Range: -20 / +55oC 12) Dissipation factor: f_;0.10 13) Testing voltage: T-T 1.2Ur 2s,T-C 2,000V AC 10s 14) Standard: IEC252
Supplier: Capacitance and dissipation factor bridge, tan delta test set, oil breakdown tester, oil resistively and dissipation factor test set, high voltage breakdown tester, standard sf6 gas filled capacitors, insulation resistance testers, transformer oil testing laboratory, on-site testing services
Services: Transformer oil testing laboratory, on-site testing services
The sf6 gas insulated standard capacitor is used together with a c and tan delta measuring bridge as the comparison standard leg of the bridge. It is used as capacitance standard in measuring bridge circuits to measure the dielectric dissipation factor tan-delta, further-more, it can be used as high-voltage capacitor for voltage divider circuits of high-voltage transformer test. Highest long-term stability is guaranteed and proven over 20 years. A wide range of different sizes, values and voltage ranges are available. We can produce 5kv~1600kv. We can also provide the professional solutions and equipments for: withstanding voltage testing, c & tan-delta (power factor) testing, partial discharge (pd) testing and impulse voltage testing.
CL11 Series Polyester Film Capacitor CAPACITANCE RANGE: 0.001~0.47uf Rated voltage: 200v\250v\400v\450v Capacitance tolerance: ¡¾5% Operation temperature: none Leakage current: Dielectric dissipation factor£ºtg¥ä¡Â0.002 (50Hz¢¦100Hz).
Aluminum electrolytic capacitors 1) wide temperature and voltage range 2) capacitance range (uf): -10% ~ 20% 3) high stability 4) small capacitance change 5) low dissipation factor, low leakage current
Specifications Operating temp range -40íµ~+105íµ Capacitance range 0.0022ª¦F~10ª¦F Rated voltage 275VAC Capacitance tolerance í+5%(J)íóí+10%(K)íóí+20%(M) Dissipation factor í_10í-10-4(23íµ f=1KHz) Withstand voltage 4.3UN(10S) Insulation resistance Cí_0.33ª¦F Rsí¦15000Mª+ C>0.33ª¦F Cí-Rsí¦5000S (23íµ 1min).