Compact, space saving design No special tools are needed for assembly Reduce space for storage and transportation High flexibility Designed according to customer needs Dimensions : â?? Height from 300 mm up to 1200 mm â?? Width from 300 mm up to 1000 mm â?? Depth from 200 mm up to 300 mm Protection degree up to IP 65 Can be equipped cable compartment Rated current up to 630A Design and assembled according to IEC 439-1 All routine tests are applied Polyester powder RAL 7032 or 7035 As Reqest Incoming and outgoing from top or bottom Can be recessed Frame Must Be added or wall mounted Applications : Main & outgoing switchboards Motor Starter Load Center up to 72 Lines Available in stainless steel as per Request
Panel Meter
Modular Enclosures Socket
Body : made of cold rolled steel chemically treated and painted with electrostatic powder coating . Bar : made of brass Screws and connecting tools : iron plated with zinc.
Plastic Distribution Box
Legend for panel design Door of low-voltage compartment Opening for locking or unlocking the low-voltage compartment door Option: Capacitive voltage detecting system for feeder and busbar High-voltage door Inspection window for checking the switchingdevice truck Inspection window for reading the indicators Door handle Openings for switchingdevice truck operation Opening for earthing-switch operation Pressure relief duct Busbars Bushings Post insulators Block-type current transformer Opening for locking or unlocking the high-voltage door Opening for mechanical charging of circuit-breaker closing spring Option: Make-proof earthin switch Cable sealing ends Option: Voltage transformer Earthing busbar Low-voltage plug connector Vacuum interrupters
Room planning dimensions
Standard Withdrawable Vacuum Circuit breaker type 3AH equipped with: Tripping Coil, Closing Coil, and Spring Charging Motor. Variations for Circuit Breaker options Range of Operating Voltages Second Trip Coil Undervoltage Release Electrical Lockout Extended Auxiliary Switches for Withdrawable Metering Truck Range of voltages Open delta winding Primary Fuses, DIN style Metering Compartment Standard Withdrawable Voltage transformer, three single phase devices each with a single secondary winding Variations: Voltage Transformer options : Range of Voltages Open-Delta Winding Primary Fuses, DIN style Busbar Compartment Standard Busbar : 800 / 1250 / 2000 / 2500A Droppers: 800 / 1250 / 2000 / 2500A Low Voltage Compartment Standard 700 mm high complete Gear Plate
Plastic Distribution Box
black wire drawing form wire rode high carbon used to many industries like mattresses manufacture lot 50 ton the coil 500 kg and may be increase
This chess board is made from wood with natural seashell pieces which makes it unique. The chess pieces are pharonic like and made from metal, either the color of the pieces are silver and gold for the two teams or brone and silver. The set includes a small handmade wooden box for handling the chess pieces. The whole set is unique and handmade by very skilled artisans. Dimensions: 32 x 32 cm
Lighting And Panels And Bulb And Also Plastic Products
Product title: NS40 Base Type: B00 Barcode: 6224010283107 Ah 20h: 40 EN: 340 Positive Position: R Dimensions (mm): X : X196-Y128-H222
Product title: N80 Base Type: B00 Barcode: 6224010283121 Ah 20h: 80 EN: 680 Positive Position: L Dimensions (mm): X : X305-Y172-H220
Product title: NS25 Base Type: B00 Barcode: 6224010283091 Ah 20h: 25 EN: 215 Positive Position: L Dimensions (mm): X : X196-Y128-H222
Product title: DIN100 Base Type: B03 Barcode: 6224010283084 Ah 20h: 100 EN: 850 Positive Position: R Dimensions (mm): X : X353-Y175-H190
Product title: DIN88 Base Type: B03 Barcode: 6224010283077 Ah 20h: 88 EN: 750 Positive Position: R Dimensions (mm): X : X353-Y175-H190
Product title: DIN55 L-R Base Type: B03 Barcode: 6224010283039 Ah 20h: 55 EN: 470 Positive Position: L&R Dimensions (mm): X : X242-Y175-H190
Nickel Cadmium Batteries up to 800 AH (Ni-Cd battery or Ni-Cad battery) is the most reliable battery system available in the market today It is not surprising, therefore, that the Nickel Cadmium battery has become an obvious first choice for users looking for complete reliability, long cycle life, fast recharge, exceptionally long lifetime, low maintenance, low life-cycle cost, wide operating temperature range, environment friendly. Product Description:- Capacity up to 800 Ah.: block battery capacity is rated in ampere-hours (Ah) and is the quantity of electricity at +20 �°C (+68�°F) which it can supply for a 5-hour discharge to 1.0 V after being fully charged for 7.5 hours at 0.2 C5 A. Cell voltage: The nominal voltage for this electrochemical couple is 1.2 V According to IEC 60623 Standards : There are a number of methods which are used to size Nickel Cadmium batteries for standby floating applications. The method is the IEEE 1115 recommendation (accepted internationally)
Automatic Voltage Regulator (AVR) AVR Automatic Voltage Regulator (AVR) with on Load Tap changer The On Load Tap Changer, automatic voltage regulator (AVR) is used to compensate the voltage drop in the electrical networkâ?? so that customers at the line end receive the same average voltage value as those closer to the source. The voltage value reduction affects the operational quality of the rotating machines and increases the losses due to the high current drawn due to the voltage reduction. It also affects the quality of the illuminating system. EGYTRAFO Group produces the Automatic Voltage Regulator (AVR) with rating up to 630 A & 9 tapping positions. -The AVR is flange mounted (ON TANK) or (IN TANK) type according to the rating of the transformer and a remote tap changer control cubicle (RTCC) Our ranges are up to 630 A, up to 22 KV and more than 5 taping positions on request. Automatic Voltage Regulator (AVR) applications: you can use it as a safely starting machines such as induction motors and synchronous motors Also, boosters to give a small boost to distribution cable for compensating the voltage drop you can get the same advantage of the Variac Automatic Voltage Regulator (AVR) advantages: Increased KVA rating for a given size and mass Less amount of copper Due to the smaller size, the cost is less compared to a two â?? winding transformer The resistance and reactance are less compared to a two â?? winding transformer and hence it has superior voltage regulation The Volt-ampere rating is more compared to a two â?? winding transformer It is possible to get a smooth and continuous variation of voltage