Unit Price: USD 17 Target Region: ORF1ab, N gene Accuracy: 100% Recommended PCR: CFX96 Real Time PCR System (Bio Rad) ABI7500 Real Time PCR System (Thermo Fisher Scientific) Box Size: 10 cm * 6.5 cm Certification: ISO 13485 ISO 9001 Korea GMP European CE USA EUA
Unit Price: USD 12 Target Region: RdRP gene and E gene Accuracy: 100% Recommended PCR: Compatible with major PCR Size: 1 box / L 92* W 86* D 54 cm
Product Details: Number of Reactions(Preps)/Kit : 100 T Brand : RADI Storage Temperature : -25 C to -15 C Sample Material : RNA extracted from Nasopharyngeal and/or Oropharyngeal swab Target : S gene, RdRP gene Cat. No : RV008 The RADI COVID-19 Detection Kit is intended for the presumptive qualitative detection of specific nucleic acid sequences from the genome of the SARS-CoV-2 S gene and RdRP gene from the upper respiratory specimens such as Nasopharyngeal swab, Oropharyngeal swab.
Brand: LAB Genomics Product name: Labgun Covid-19 RT-PCR Kit Order Type: future / at once Product Type: PCR based Detection kit Season: 2020
Application Suspected case test in epidemic area Early test of fever clinic and CDC Screening of primary medical institutions Inspection of floating population in public areas Performance Characterisitics Sample tyep: nasal swab Time to result: 15-20 minutes Sensitivity: 97.70% Specificity: 99.84% Accuracy:98.97% Layperson study statistics 99.84% of non-professionals carried out the test without requiring assistance 99.82% of different types of results were interpreted correctly. Parameters: A Short Test Time: 15 mintues B Accuracy: More than 98.1% C Sensitivity: 96.4% Specificity: 100% D Easy operation: Nasal Swab E One Step solution F Lower cost with high efficiency G Package: 1 Test/Kit, 5 Tests/Kit, 25 Tests/Kit H It can detection for Omicron Virus Price and Minumum Quantity Price FOB in USD: 1.5Minimum Order Qty: 500000 Pieces Production Capacity: 100 Million Boxes Per WeekPackaging: 1,5,20,25,40,100,200 Pcs Per Box Sample: Available. Sample Cost Born By Buyer Product Model And Origin Brand: jwfModel: jwf01 Seller Code: Jwf Standards: Ce Competitive Advantages Lower cost with high efficiency Detection for omicron virus Easy operation Short test time Other Details Omicron covid test kit Covid test kit Omicron test card Covid test card
CORONAVIRUS (SARS COV-2) ANTIGEN DETECTION KIT - Price 2.99 USD ONLY FOB Netherlands Remaining Qty: 60,000 pcs
Angiten-COVID-19 Virus Test Kit (Colloidal Gold) Quantity of box: 25 persons/box Brand: Easysweet NMPA (National Medical Products Administration): Approved CE: with CE mark BfArM: listed Test Method: Antigen Test Result Time: 10-15 mins Sample Type: Nasal Swab Sensitivity: 96.70% Specificity: 100% Accuracy: 98.94% Shelf Life: 24 months Storage Temperature: 2-30 Degree Celsius Country of Origin: Made in China Additional Information: Production Capacity: 1 million Delivery Time: 10-15 days Packaging Details: 25 tests in a pack, 40packs/ carton Angiten-COVID-19 Virus Test Kit is an in vitro diagnostic rapid test for the qualitative detection of SARS-CoV-2 antigen (Ag) in human nasopharyngeal swab specimens from individuals who meet COVID-19clinical and / or epidemiological criteria. It can be used by professional only. Price and Minumum Quantity Price FOB in USD: NegotiableMinimum Order Qty: 10000 Production Capacity: 1000000Packaging: 25 Persons/box Sample: Available. Sample Cost Born By Buyer Product Model And Origin Brand: Easysweet HS Code: 3822009020 Standards: Ce Competitive Advantages Best price with shortest delivery time Best price with shortest delivery time Best price with shortest delivery time Best price with shortest delivery time Other Details Angiten-covid-19 virus test kit (colloidal gold) Angiten-covid-19 virus test kit (colloidal gold) Angiten-covid-19 virus test kit (colloidal gold) Angiten-covid-19 virus test kit (colloidal gold)
Access Bio Care Start Covid-19 Rapid Antigen Test Kit Product Details: Number of Reactions(Preps) per Kit : 1 Brand : Access Bio Test Method : Antigen Test Result Time (Rapid Kits) : 10 min Sample Type ; Nasal Swab Packaging Size : 20 Test Kits/Box Packaging Type : Box The CareStart COVID-19 Antigen test is a lateral flow immunochromatographic assay intended for the qualitative detection of the nucleocapsid protein antigen from SARS-CoV-2 in nasopharyngeal or anterior nasal swab specimens directly collected from individuals who are either suspected of COVID-19 by their healthcare provider within first five days of symptom onset, or from individuals without symptoms or other epidemiological reasons to suspect COVID-19 when tested twice over two or three days with at least 24 hours and no more than 48 hours between
COVID-19 Rapid Test Kit IgG + IgM (Colloidal Gold) comes in packs of 40 tests and contains: GCMS manufactures COVID-19 antigen test kit, the GENEDIA W COVID-19 Ag which is listed on the EU common list, also with GMP and ISO certifications. GENEDIA W COVID-19 Ag is unaffected based on the in-silicon analysis of the mutations in the nucleocapsid (N gene) of Omicron viruses. Letter of statement is available upon your request. To get over COVID-19 pandemic, especially the recent Omicron breakout, currently we are doing big promotions for three kinds of COVID-19 Ag kit. All are in stock and available right away. 1. Nasopharyngeal 2. Nasal 3. Saliva Price and Minumum Quantity Price FOB in USD: negotiable 0.8 to 1.8Minimum Order Qty: None Pieces Production Capacity: 3,000,000/monthPackaging: 20 Tests/kit, 30 Kits/box, 12 Boxes/pallet Sample: Available. Sample Cost Born By Supplier Product Model And Origin Brand: GENEDIAModel: 643G-S (Saliva) Seller Code: Genedia w covid 19 agHS Code: 3002.15 Standards: Ce Competitive Advantages Allow wider testing with fast test time (10 minutes) All necessary materials provided / no equipment needed Sensitivity: 93.33%, specificity: 100% Free sample. no moq. price is negotiable. customized packing. Other Details 20 tests / kit 24 months from the date of manufacture 2 ~ 30c(35.6 ~ 86f) available for room temperature deliver In stock. fast delivery. 1 x Instructions for Use Manual 40 x Test Cassettes 1 x Buffer 40 x Dropper
Covd-19 IgG/IgM Rapid Test Cassette (Whole Blood/Serum/Plasma) is a solid phase immunochromatographic assay for the rapid, qualitative and dierential detection of IgG and IgM antibodies to 2019 Novel Corona Virus in human whole blood, serum or plasma. Specification.jpg Product: Rapid Diagnostic Test Kit Item: Corona Virus Test Kit Specimen: Whole Blood/Serum/Plasma Format: Strip/Cassette Port of Loading: Shanghai OEM and ODM: OEM/ODM Welcome Shipping: By UPS, FEDEX, DHL, TNT, by air or by sea MOQ for Private label: Low MOQ 1600 boxes, Please contact us. Note: Store this product in a cool and dry place, avoid direct sunlight, stay away from places that children can contact, and avoid eye contact. If you have allergies to this product, please stop using and consult a doctor. COVID-19 Corona Virus Rapid Test Kit11.pngCOVID-19 Corona Virus Rapid Test Kit12.png
High accuracy High quality, with CE certificate. 10 tests per box
GENEDIA W COVID-19 IgM/IgG device is a chromatographic immunoassay kit for the rapid and differential detection of immunoglobulin M (lgM) and immunoglobulin G (IgG) against COVID-19 using serum, plasma and whole blood. Allow wider testing with fast test time (10 minutes) Perform directly at the point of care High capacity to meet the most urgent medical and public health needs Package Unit : 20 Tests/Kit Expiration Date : 24 Months
COVID-19 IgM/IgG Antibody Detection Kit (Colloidal Gold Immunochromatography) is suitable for the qualitative detection of COVID-19 by detecting SARS-CoV-2 IgM/IgG antibodies in human serum, plasma, or whole blood. Common signs of infection with SARS-CoV-2 include respiratory symptoms, fever, cough, shortness of breath, and dyspnea. In more severe cases, infection can cause pneumonia, severe acute respiratory syndrome, kidney failure, and even death. SARS-CoV-2 can be excreted through respiratory secretions or transmitted through oral fluids, sneezing, physical contact, and through air droplets
The COVID-19 RT-PCR Detection Kit is a real-time RT-PCR test intended for the qualitative detection of nucleic acid from the SARS-CoV-2 in upper and lower respiratory specimens (such as anterior nasal swabs, mid-turbinate nasal swabs, nasopharyngeal swabs, oropharyngeal swabs, sputum, lower respiratory tract aspirates, bronchoalveolar lavage, and nasopharyngeal wash/aspirate or nasal aspirate) from individuals suspected of COVID-19 by their healthcare provider. Testing is limited to laboratories certified under the Clinical Laboratory Improvement Amendments (CLIA) of 1988, 42 U.S.C. 263a, to perform high complexity tests. Results are for the identification of SARS-CoV-2 RNA. The SARS-CoV-2 RNA is generally detectable in upper and lower respiratory specimens during the acute phase of infection. Positive results are indicative of the presence of SARS-CoV-2 RNA; clinical correlation with patient history and other diagnostic information is necessary to determine patient infective status. The agent detected may not be the definite cause of disease. Positive results do not rule out bacterial co-infection with other viruses. Laboratories within the United States and its territories are required to report all positive results to the appropriate public health authorities. Negative results do not preclude SARS-CoV-2 infection and should not be used as the sole basis for patient management decisions. Negative results must be combined with clinical observations, patient history, and epidemiological information. The COVID-19 RT-PCR Detection Kit is intended for use by qualified trained clinical laboratory personnel specifically instructed and trained in the techniques of real-time PCR and in vitro diagnostic procedures. The COVID-19 RT-PCR Detection Kit is only for use under the Food and Drug Administration's Emergency Use Authorization. PRINCIPLE OF DETECTION This product is a fluorescent probe-based Taqman RT-PCR assay system. Firstly, the RNA of SARS-CoV-2 will be reverse transcribed into cDNA by reverse transcriptase, and then PCR amplification will be performed with cDNA as template. During amplification of the template, the TaqMan probe will be degraded due to the 5'-3 polymerase activity and exonuclease activity of Taq DNA polymerase, then the separation of fluorescent reporter and quencher enables the fluorescent signal to be detected by instrument. The ORF1ab gene of SARS-CoV-2 will be detected qualitatively by FAM channel, the N gene of SARS-CoV-2 will be detected qualitatively by JOE channel, the E gene of SARS-CoV-2 will be detected qualitatively by ROX channel, and the internal reference will be detected by CY5 channel. dUTP and UNG enzyme are used in the kit to prevent contamination of the amplified products. Internal reference is used in the kit for quality control starting from sample collection
Indication: Qualitative detection of nucleic acid from SARS-CoV-2 in upper and lower respiratory specimens (such as anterior nasal swabs, mid-turbinate nasal swabs, nasopharyngeal swabs, oropharyngeal swabs, sputum, lower respiratory tract aspirates, bronchoalveolar lavage, and nasopharyngeal wash/aspirate or nasal aspirate) from individuals suspected of COVID-19 by their healthcare provider. Emergency use of this test is limited to authorized laboratories. Authorized Laboratories: Laboratories certified under the Clinical Laboratory Improvement Amendments of 1988 (CLIA), 42 U.S.C. 263a, to perform high complexity tests. This letter is in response to your1 request that the Food and Drug Administration (FDA) issue an Emergency Use Authorization (EUA) for emergency use of your product,2 pursuant to Section 564 of the Federal Food, Drug, and Cosmetic Act (the Act) (21 U.S.C. 360bbb-3). On February 4, 2020, pursuant to Section 564(b)(1)(C) of the Act, the Secretary of the Department of Health and Human Services (HHS) determined that there is a public health emergency that has a significant potential to affect national security or the health and security of United States citizens living abroad, and that involves the virus that causes COVID-19. Pursuant to Section 564 of the Act, and on the basis of such determination, the Secretary of HHS then declared that circumstances exist justifying the authorization of emergency use of in vitro diagnostics for detection and/or diagnosis of the virus that causes COVID-19 subject to the terms of any authorization issued under Section 564(a) of the Act. Having concluded that the criteria for issuance of this authorization under Section 564(c) of the Act are met, I am authorizing the emergency use of your product, described in the Scope of Authorization of this letter (Section II), subject to the terms of this authorization. I. Criteria for Issuance of Authorization I have concluded that the emergency use of your product meets the criteria for issuance of an authorization under Section 564(c) of the Act, because I have concluded that: 1. The SARS-CoV-2 can cause a serious or life-threatening disease or condition, including severe respiratory illness, to humans infected by this virus; 2. Based on the totality of scientific evidence available to FDA, it is reasonable to believe that your product may be effective in diagnosing COVID-19, and that the known and potential benefits of your product when used for diagnosing COVID-19, outweigh the known and potential risks of your product; and, 3. There is no adequate, approved, and available alternative to the emergency use of your product. 4 II. Scope of Authorization I have concluded, pursuant to Section 564(d)(1) of the Act, that the scope of this authorization is limited to the indication above.
Commodity: Covid-19 RT-PCR Detection Kit Spec.96 tests/kit Price:FOB SHANGHAI USD3.30/test, USD316.8/kit $3.60/TEST CIF NY AIRPORT OR OTHER MAJOR AIRPORTS USA OR EUROPE OR S. AMERICA OR MIDDLE EAST Payment: T/T ADVANCE 50% BALANCE BEFORE DEPARTURE OR Sight Irrevocable TRANSFERABLE LC Delivery: By AIR, 50days after receipt and confirmation of LC
Sample Types : Including Nasopharyngeal swab, Oropharyngeal swab, Sputum Controls : Internal control, UNG enzyme and dUTP used to reduce risk of contamination, false positive and false negative results Product Information Upper and lower respiratory specimens such as anterior nasal swabs, mid-turbinate nasal swabs, nasopharyngeal swabs, oropharyngeal swabs, sputum, lower respiratory tract aspirates, bronchoalveolar lavage, and nasopharyngeal wash/aspirate or nasal aspirate. Authorized Laboratories Laboratories certified under the Clinical Laboratory Improvement Amendments of 1988 (CLIA), 42 U.S.C. 263a, to perform high complexity tests. About Emergency Use Authorization (EUA) This test (1) has not been FDA cleared or approved, (2) has been authorized by FDA under an EUA for use by authorized laboratories, (3) has been authorized only for the detection of nucleic acid from SARS-CoV-2, not for any other viruses or pathogens, and (4) is only authorized for the duration of the declaration that circumstances exist justifying the authorization of emergency use of in vitro diagnostics for detection and/or diagnosis of COVID-19 under Section 564(b)(1) of the Act, 21 U.S.C.360bbb-3(b)(1), unless the authorization is terminated or revoked sooner.