Conductor: cu, ccs, cca Insulation: foam pe Shielding layer: al foil Braiding: cu, cca Jacket: pvc 100meter/roll or 305meter/roll in one seperated transparent bag, and twine in individual spool
Foshan sonata offers coaxial cable, lan cable and control/signal cable at competitive price and prompt delivery. Model: rg6, rg11, rg59, utp/ftp/stp cat 5e, cat 6 and more. Conductor: highly conductive annealed copper, copper clad steel (ccs). Insulation: foam pe. Screening: various thickness copper foil/aluminum foil available. Outer jacket: pvc, pe, lsf, ls0h. Customized specifications and materials are welcome. Wide range of packaging solutions is available. 100m/reel, 250m/reel, 305m/reel or customized.
Specification: 1) Conductor material: CU / CCS /CCA 0.8mm /0.9mm/1.0mm/1.02mm/1.13mm 2) Dielectric: 4.8 Foaming PE 3) Foil: Al foil / Copper foil/ bonded foil 4) Braiding dia.: 0.12, 0.15, 0.16mm 5) Wire net No: 32, 48, 120 and up 6) Coverage: 28%, 40%, 60%, 80%, 90% and up 7) Jacket: OD7.0mm.
1.Lenth:1.5m od:3.2 color:black 2.Raw material: 10*0.10ccs 3.Have rosh ul 3c standad 4.Use for sned audio video signal. Nature pack stand export carton.
RF3212A Screw type cable without centre pin Coaxial cable. Model: RF3212A IEC male to IEC female high shielded cable Specifications: Accoding to EN60966-2-4 Description: Specification: Charateristic impedance: 75¡À3 ohm Rrturn loss:£¾12db from 30mhz to 1000mhz Screening factor:£¾85db from 30mhz to 1000mhz.
Insulated power cable, plastic insulated power cable, aerial insulated cable, control cable, aluminum conductors steel- reinforced (ACSR), aluminum stranded conductors, polyvinyl chloride (PVC) insulated wires, various flame- retardant and fire-resistant wires and cables, special cable, etc. Weight/100m(kg).
(1).Application: ABC Cable Primarily used for 120 volt overhead service applications such as street lighting,outdoor lighting,and temporary service for construction.To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75oC for polyethylene insulated conductors or 90oC for crosslinked polyethylene(XLP)insulated conductors. (2).Construction: Code Word Phase conductor Bare Neutral Messenger Nominal Lay Length Weight Per 1000ft. (lbs.) Allowable Ampacities+ Size (AWG) Stranding Insul. Thick. (Mils) Size (AWG) Stranding Rated Strength (lbs.) inches XLP POLY XLP POLY AAC Neutral-messenger Pekingese 6 1 45 6 7 563 10.36 61 61 85 70 Collie 6 7 45 6 7 563 10.36 64 64 85 70 Dachshund 4 1 45 4 7 881 10.36 92 92 115 90 Spaniel 4 7 45 4 7 881 10.36 96 96 115 90 Doberman 2 7 45 2 7 1350 14.88 147 147 150 120 Malemute 1/0 9 60 1/0 7 1990 14.88 234 234 205 160 Wooden Drum.
CE cable :H07V-U/H07V-R/H07V-K Despription: Related temperature :70C Related voltage:300/300V Reference standard: DIN VDE 0281-3-2001 HD21.3S3:1995+A1:1999 Tinned or bare,stranded or solid copper conductor PVC/T11 insulation Application: For power supply and lighting. In rolls.
UL2464 Wire and Cable Applications: As measuring, monitoring and control cable, it is suitable for the places of machine tool manufacturing, complete equipment installation engineering, power station, refrigeratory equipment, OA equipment, data processing system and heating and air-condition system. Properties: Heat resistance, good insulation property, excellent chemical performance, extruding sheath Standards: UL 758 Structure: Conductor: fine strands of tinned copper wire, exellent corrosion resistance. Insulation: special PVC Colour: acc. to UL 758 Sheath: 80 heat-resistant flame-resistant PVC, pass VW-1 flame testing Colour: black (RAL9005) green (RAL6018) Orange(RAL2003) purple(RAL4001) Or refer to customers requirement. Technical data: Rated voltage: 300V Test voltage: 2000V Temperature range: Fixed installation: -40--+80 Flexing installation: -10--+80 The minimum bending radius: Fixed installation: 4×external diameter Flexing installation: 15×external diameter.
3.5mm ST plug to 3.5mm ST jack RCA female to 2RCA male 3.5mm ST jack to 2RCA male.
Supports Measuring Values, Output Tests, and Adaptations on control modules using the new UDS/ODX/ASAM protocol. Adds new UDS addresses and updated ODX data for 2010 models. Includes support for TP1.6 protocol which is required for the 6J Ibiza and speeds up access on many modules in other models. The Select Control Module screen now shows "Installed Modules" rather than "Common Modules" if the car being worked on is new enough to have a proper CAN Gateway. Modified SRI Screen to show more info and force user to select a job before proceeding. Adds drop-box function selection in Basic Settings and Adaptation. Reads Mileage stored in many EDC16 ECUs. New CODES file, now with over 13, 000 fault code and measuring value texts. New USB drivers for enhanced PC compatibility and stability. New firmware for HEX interfaces required for compatibility with 6J Ibiza Updated Label files; better documentation for new and existing models. Compared with the 812, the 908 has its biggest advantage. It lies in that the 908 can match Airbags under the protocol of UDS while the 812 can only read code, erase code and do coding, and it cannot match airbags. Pls check the comparence in the following pictures. The icons of 908 are activated while the ones of 812 are not. The new models that the VW launches now or in the future, such as New Bora and Lavida, will all use UDS protocol. Besides, the VAS5054 in the market nearly doesn't support UDS protocol.
ABC Cable 1) Standard: IEC60502/BS 2627 2) Voltage: 0.6/1kV 3) Certificate: ISO, CCC 4) MOQ: 3KM ABC Cable Aerial bundled cable Standard and application scope: This product is produced in accordance with the standard of IEC60502/BS 2627. The products,Cu core or Al core XLPE or HDPE aerial insulated electric power cable,may be used for the fields where the A.C.rated voltage U(Um) is 0.6/1kV. Using feature: 1) The max. long-term operating temperature of cable conductor(cable having supporting structure): a) XLPE insulation :90¡ãC b) HDPE insulated 75¡ãC 2) When short circuit (the Max. lasting time is not over 5 seconds), the Max.temperature of the cabl: a)XLPE insulated: 250¡ãC b)HDPE insulated 150¡ãC 3) When laying, the temperature should not be lower than -20oC; 4) The permitted bend radius should not be less than the diameter of cylinder that had been used for the bend testing. 5) Cables installed in air; 6) Ambient temperature:40oC 7) Intensity of solar radiation:1000w/m2.
H07RN-F Rubber Insulated & Jacketed Voltage:450/750V Standard:HD22.1/HD22.4 Size:1x1.5-630,2x1.5-95,3x1.5-300,4x1.5-300sqmm Application: The products are used for household electrical appliance, electrical tools and various mobile, electrical equipments of A.C rated voltage 450/750V or lower. Si-rubber is used as connection of appliance in moto, metallurgy, eletrical power, oil-fields, chemistry industrial, also in the process of heating for stimulating the liquid. It have weather-proof character and certain grease-proof character and are suitable for outdoor usage and the occassio with greasy dirt. Also can be used for various mobile electrical devices, bearing strong mechanical force. Standard: It is manufactuerd according to HD22.1 & HD22.4. Size: 1. Single Core: 1.5 to 630sqmm 2. Two Cores: 1.0 to 25sqmm 3. Three Cores: 1.5 to 300sqmm 4. Four Cores: 1.5 to 300sqmm 5. Five Cores: 1.5 o 25sqmm.
PVC Insulated & Sheathed Cable Cu(or Al)/PVC/PVC Standard:IEC 60502-1/BS6346 Voltage:0.6/1kV Certificate:TUV SUD PSB, CCC Standard : It is manufacture under IEC 60502-1/BS6346, also can be made to order. Application: It is used to transmit and distribute power on the power line of A.C. rated voltage 0.6/1kV. Using features: 1. Rated voltage: Uo/U: 0.6/1kV 2. No. of core: Ranging from single core to 5 cores, inlcuding earth core. 3. The highest allowed operating temperature of conductor for long-term working is 70oC. In short-circuit (Max. long-term is no more than 5 seconds), the highest temperature for conductor is no more than 160oC. 4. D.C. resistance of the conductor complies with the stipulations of IEC 60502-1/BS6346. 5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated. 7. Working Frequency Voltage Test: 2.5Uo+2kV/5min without puncture.
sell coaxial cable with messenger,messenger wire CCS + FPE + Al foil + braiding + jacket£¬diameter: 1.00, 1.02, 1.25, 1.66,2.15, 2.77mm available 2.dielectric: foamed PE, solid PE available 3.shield: AL foil (bonded/ unbonded), copperized AL foil (bonded/ unbonded) 4.braiding wire: Cu, Al-Mg, TC available braiding wire diameter: 0.12mm, 0.15mm, 0.16mm available braiding net number: 32, 48, 64, 96, 128, etc braiding coverage: 30-95% 5.jacket: PVC, PE color: white, black etc. 6.OEM and client's specification are acceptable. Packing: 1.packing length:100,200,305m/roll; 100,200,300yard/roll;n other length available according to client's request 2.inner packing:wooden drum, plastic drum, plastic bag 3.outer packing:carton,plastic bag 4.other packing available according to client's request.
Structure: Solid bare copper conductor, pe insulation, center cross skeleton, aluminum foil screen, pvc/pe /lsoh sheathed. Standard: Europe celenec en 50173/50167 Usa eia/tia568b International iso/iec 11801/61156 China yd/t 1019-2001. According to client request.
Structure: 1 Specifications: 0.4mm, 0.5mm, 0.6mm, 0.65mm, 0.7mm, 0.8mm Cores; 2c; 4c; 6c; 8c; 10p, 20p, 25p; 50p; 100p, 200, 300pair... Indoor, outdoor telephone cable is avialable. Self supporting, white, black color is ok... 2, a) Conductor: Copper, tinned copper, steel clad copper B) Insulation: PE, PP, PVC C) Screening: Aluminum foil, earth wire, no screening D) Jacket: LDPE, PVC, LOSH 3, Custom colors available upon request 4, Round and flat available 5, Custom specifications and lengths available upon request.
RG6 Coaxial Cable: 1.02CCS/BC+4.57mm Foamed PE+Bonded AL-Foil+0.12mm*80 AL-Mg alloy Braiding+6.9mmPVC Specification : Inner conductor:1.02BC/CCS Dielectric:4.57mm Foamed PE AL-Foil:Bonded AL-Foil;Ordinary AL- Foil, Double-Sided AL- Foil, Single-Sided AL-Foil Braided material: cu;AL-Mg alloy;Copper Clad Aluminum Braided diameter:0.12mm;0.13mm;0.14mm;0.15mm..... Braided net:64;80;96;112.... Braided coverage:50%;60%;70%;80% Jacket:6.8mmPVC ;6.9mmPVC. Characteristics: Impedance:75¡À3.0hms Capacitance(pF/m) :54¡À3.0 Nominal Velocity of Propagation: 85% Return loss(¡ÝdB) : VHF 5-300MHz ¡Ý20dB UHF 300-960MHz¡Ý18dB. Attenuation [@68¡ã F.(20¡ãC.)]: Frequency (MHz) Maximum(dB/100m) 5 1.90 55 5.25 83 6.40 187 9.35 211 10.00 250 10.82 300 11.64 350 12.63 400 13.61 450 14.43 500 15.09 550 16.08 600 16.73 750 18.54 865 20.01 1000 21.49 Applications: 1)CATV-community antenna television 2)CCTV-closed-circuit television 3)DBS-direct broadcasting satellite. 1.Client's specification and designation are welcome. 2.Don't hesitate to contact us! Inquiries and visits are more than welcome. 1)100m/roll,200m/roll,305m/roll 100yard/roll,200yard/roll,300yard/roll (other lengths available client's request) 2)Inner packing:Wooden reel,plastic reel and paper reel available 3)Outer packing:Carton box,pull out box,pallet available (other packing available according to client's request).
5 kv grade single core airfield lighting cables with stranded annealed plain copper conductor xlpe insulated 7 pe or pvc sheathed of size 6 sq.Mm. 500 / 1000 mtrs in non returnable wooden drum with qty tolernce of 5%.
Construction 1)Center conductor: Copper clad steel 2)Dielectric:Foam PE 3)1st shield: Bonded Aluminum Foil(100%) 4)2nd shield:Al-Mg braid(60%) 5)Jacket:PVC. 500ft/1000ft coil in carton.