PVC Insulated & Sheathed Cable
Cu(or Al)/PVC/PVC
Standard:IEC 60502-1/BS6346
Voltage:0.6/1kV
Certificate:TUV SUD PSB, CCC
Standard :
It is manufacture under IEC 60502-1/BS6346, also can be made to order.
Application:
It is used to transmit and distribute power on the power line of A.C. rated voltage 0.6/1kV.
Using features:
1. Rated voltage: Uo/U: 0.6/1kV
2. No. of core: Ranging from single core to 5 cores, inlcuding earth core.
3. The highest allowed operating temperature of conductor for long-term working is 70oC. In short-circuit (Max. long-term is no more than 5 seconds), the highest temperature for conductor is no more than 160oC.
4. D.C. resistance of the conductor complies with the stipulations of IEC 60502-1/BS6346.
5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated.
7. Working Frequency Voltage Test: 2.5Uo+2kV/5min without puncture.
PVC Insulated & Sheathed Power Cables Standards: IEC60502, GB/T12706-2008 Application: It is suitable to be installed in duct, tray or direct burial, with rated voltage of U0/U (0.6/1KV) for transmitting electricity. Service Conditions: 1. Regular nominal cross-sectional areas: 1.5 mm2, 2.5 mm2, 4 mm2, 6 mm2, 10 mm2, 16 mm2, 25 mm2, 35 mm2, 50 mm2, 70 mm2, 95 mm2, 120 mm2, 150 mm2, 185 mm2, 240 mm2, 300 mm2, 400 mm2, 500 mm2, 630 mm2, 800 mm2, 1000 mm2, 1200 mm2 2. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will not be affected by eciencies in the installation.
Cable Standard IS 694:2010, BS 6500 Silent Features - High Flexibility - Excellent resistant to moisture, abrasion, grace, oil - Long Life - Excellent mechanical & electrical properties Technical Data Working Temp : Max.+70�°C Nominal Voltage : 1.1 KV Test Voltage : 3.0 KV Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200, 300 , 500, 1000m. Conductor Flexible Bare or Tinned Bunch Copper as per IS:8130-1984 Insulation PVC as per IS:5831-1984 Sheath PVC as per IS:5831-1984 Core Color As per IS 694 : 2010 2 Core â?? Red & Black 3 Core â?? Red, Black, Green or Red, Yellow and Blue 4 Core - Red, Yellow, Blue and Green or Black Application Ideal For industrial induction motor, power tools, electrical machinery etc.
Control Cable,450/750V, Max.allowable working temperature is 70 Degree. Laid up indoors, in the channels, underground and fixed places where screening is( not) required. Type Designation KVV Copper conductor PVC insulated PVC sheathed control cable KVVP Copper conductor PVC insulated PVC sheathed KVVP2 Copper conductor PVC insulated PVC sheathed KVV22 Copper conductor PVC insulated PVC sheathed steel tape armored control cable KVV32 Copper conductor PVC insulated PVC sheathedsteel wire armored control cable KVVP22 Copper conductor PVC insulated PVC sheathed Cu-wire braid screening steel-tape armoring control cable KVVP2-22 Copper conductor PVC insulated PVC sheathed Cu-tape screening steel-tape armoring control cable
PVC Insulation and Sheath Control Cable
This cables are used as power distribution and transmission at rated voltage of 0.6/1kV. Working temperature: max 70 degree centigrade Short circuit: 5 seconds at max 160 degree centigrade Models: VV: Copper Core, PVC insulated and Sheathed Electric Cable VLV: Aluminum Core, PVC insulated and Sheathed Electric Cable VV22: Copper Core, PVC insulated, Steel tape armoured, PVC Sheathed Electric Cable VLV22: Aluminum Core, PVC insulated, Steel tape armoured, PVC Sheathed Electric Cable VV32: Copper Core, PVC insulated, Fine steel wire armoured, PVC Sheathed Electric Cable VLV32: Copper Core, PVC insulated, Fine steel wire armoured, PVC Sheathed Electric Cable VV42: Copper Core, PVC insulated, Heavy steel wire armoured, PVC Sheathed Electric Cable VLV42: Aluminum Core, PVC insulated, Heavy steel wire armoured, PVC Sheathed Electric Cable ZR-VV: Copper Core, PVC insulated and Sheathed, Flame retardant Electric Cable ZR-VLV: Aluminum Core, PVC insulated and Sheathed, Flame retardant Electric Cable Installation: While installation, the temperature should not lower than 0 degrees Celsius, if the ambient temperature is lower than 0 degrees Celsius, the cable should be preheated. The bending radius should not be smaller than 8 times of diameter of cable. After installation, voltage withstand test for 15 minutes at 8.4kV direct current should be performed.
Application :- The Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with PVC compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The inner & outer sheaths can be PVC, HR PVC, FRLS, HR-FRLS or FR depending upon the application and requirement. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C or +85�°C in HR PVC Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 & 4 core. Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:1554 (Part-1) Packing : 500 / 1000 meters on drums
Application :- The XLPE (Cross Link Poly Ethylene) Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with XLPE compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The outer sheaths can be PVC, HR PVC, FRLS or FR depending upon the application and requirement. Technical Advantage of XLPE Insulation :- Higher current rating, higher short circuit rating (approx 1.2 times that of PVC), thermosetting in nature, higher insulation resistance (1000 times more than PVC cables), higher moisture resistance, better resistance to surge currents, low dielectric losses, better resistance to chemicals and corrosion, longer service life. Comparatively higher cable operating temperature 90�°C and short circuit temperature 250�°C. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +90�°C Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:7098 (Part-1) Packing : 500 / 1000 meters on drums
33kV XLPE Insulation DSTA PVC Sheath Power Cable
Application :- These multi core flexible cables are used for wiring in control panels, machines and various electrical installations in dry and damp interiors specially under typical industrial environmental conditions. Features :- Manufactured from bright annealed 99.97% pure bare copper conductors, these cables offer low conductor resistance. These wires are insulated with a special grade PVC compound formulated and manufactured in-house. The tough robust outer PVC jacket protects it from oils, greases and various chemicals and abrasions, thereby giving long life and electrical safety. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C Sizes : 0.50 to 4.00 Sq. mm in 2 core to 19 cores & 6.00 to 120.00 Sq. mm in 3 core and 4 core. Color Codes : Black and Grey Outer Sheath 2 Core Cables - Red, Black 3 Core Cables - Red, Black & Green (for Earth) 4 Core Cables - Red, Yellow, Blue & Green (for Earth) 5 Core Cables - Red, Yellow, Blue, Black & Grey Specification : IS:694 Packing : In 90 meter coils, higher sizes in drums.