Power Recording Analyzer is designed for power signal record. The power generator test items are integrated at the tester. With those test items users can make motor Power generator No load test, Short circuit test, Motor excitation step response test, motor excitatory de excitation test, motor load rejection test and grid synchronous connection test and also on
Technique index
There are 12channels voltage current sample. The analog range include 10V10V, 200V 200V, 400V 400V and 20mA 20mA. Users can switch the input range from software. Also there is one channel 100mV 100mV which allow the input signal less than 10V.
The voltage and current input range assured errors are as follow
400V 400V assured error less than 0.5V
200V 200V assured error less than 0.2V
10V 10V assured error less than 0.01V
20mA 20mA assured error less than 0.02m
100mV 100mV assured error less than 0.2mV
There are 12 channel wet contacts binary signal input. The valid and allowed input voltage is DC12-200V.
There are 3 channel relay contacts output. The maximum capacity for the contacts is AC220V 1A.
There are 2 USB port used for data export and mouse keyboard input
The LCD is 12.1 inches touch pad input mode. Make the human interface more simple.
The saved space in the tester is 32G for standard configuration
Input resistances for different channels are as follow
High pressure wireless phase detector is a dedicated test high-voltage nuclear phase tester based on national power industry standard norms and market demand, and high-voltage nuclear photographic applies to detecting the two-sided circuit breaker of the ring or dual power supply power network closed loop circuit breaker. Whether it is produced in the same phase.
Before the closed loop two power supply, you must perform a nuclear phase, otherwise a short circuit can occur, suitable for the 6KV ~ 220KV transmission line with the electrical core, the sight can reach 200 meters, and the wall can be used, and it has a test function.
Wireless high-pressure cores use wireless transmission technology, safe and reliable operation, easy to use, in line with national electric power safety equipment quality supervision and testing standards. Compared with the cable core, it is the main advantage that the lead wire connected to both grids (power supply) is removed, and the safety is used to improve the security in a manner that is not subject to any terrain and facility architecture.
Technical parameter:
Phase difference
Error 5
Frequency accuracy 0.1Hz
The voltage grade measured by this product is 6kv-220kv
Transmission distance of the transmitter and receiving host
MLC-V235 Continuous Casting Mold Level Automatic Measurement System
Overview
The automatic control for the molten steel level of the mold is one of the key technologies of continuous casting production. It is very important to reduce the labor intensity of workers, improve production efficiency, improve the quality and output of casting billet, reduce overflow and breakout of steel and improve the management level of steelmaking and continuous casting.
The molten steel is poured into the mold. In order to prevent overflow, the molten steel level must be kept stable. Otherwise, during the casting process, if the level will fluctuate too much, and slag will be involved, forming surface slag inclusion on the surface of the casting billet, affecting the quality of the billet. The test points out that the relationship between the level fluctuation and the depth of casting billet surface slag inclusion is as follows:
The experience has shown that surface slag inclusions can be eliminated when the level fluctuation is within 10mm. At the same time, if the level fluctuation is more than 10mm, the rate of longitudinal cracks on the casting billet surface is 30%. It means that the level fluctuation directly affects the surface quality of the casting billet.
The principle of the system
The eddy current type molten steel level gauge is the key to the system. The system operates reliably and has excellent performance: high temperature resistance, strong anti-interference ability, fast dynamic response (lag time
Transformer oil acid tester is a fully automatic measuring instrument which adopts the extraction method to accurately detect the insulating oil acid value. This instrument can improve the working efficiency and test accuracy, and at the same time ensure the safety of the body by reducing the operator's contact with the samples and reagents.
The acid value is the trace value of potassium sulfate that neutralizes the petroleum acid in 1g of oil, which contains a certain amount of inorganic acid and inorganic acid. The acid value includes organic and inorganic acids contained in the oil. In most cases, oil does not contain mineral acids. Therefore, the oleic acid value actually represents the content of organic acids in the oil. The organic acid contained in the new oil is mainly cyclonic acid. In the oil and in the process of use, the acid value of the oil produced by oxidation is an indicator to measure the degree of refining of the new oil. Whether the oil is running is an important indicator of the continued use of oil quality equipment.
The BPS-K600 continuous casting mould breakout prediction system artificial neural network and combines with traditional artificial intelligence and information processing technology to overcome the defects of traditional logic-based prediction models. It has the functions of self-adaptation, self-organization and real-time learning.
The breakout prediction system has an optimized industrial network structure. According to the distribution and change rules of the temperature field of the mold, it can track and respond to the breakout process in real time. It can learn and judge by itself, and provide early warning information for on-site operations. It can effectively prevent the occurrence of breakout accidents, greatly reducing the cost and improving the safety factor of continuous casting.
The system is suitable for all kinds of continuous casting machines such as square billet, round billet, rectangular billet and slab.
The composition of the system
Thermocouple: according to the on-site conditions of the mold, water tank, bolts and mold frame to desgin
Mould Oscillation and Deflection Detection Instrument
Overview
The mold is a device that shapes the cast product in continuous steel casting, and it is also the core equipment and key technology of continuous casting machine. The main function of the mould oscillation deflection detection instrument is to detect the the mould oscillation table s oscillation frequency, amplitude, deflection rate, phase, oscillation trajectory curve, etc. Through the detection and adjustment of the detection instrument, the mold moves along the outer arc of the continuous casting machine according to the given amplitude, frequency and waveform deflection characteristics.
The actual oscillation parameters of the mold oscillation table during the operation and production process and the process parameters of the cast products cannot be effectively known without the data detection of the mold deflection detection instrument, so that the operator cannot adjust the mould s production process parameters in real time according to the real-time situation of the on-site production.
The continuous casting mold deflection detection instrument independently developed by our company is suitable for various molds such as slab, square billet, round billet and shaped billet. The system obtains the process parameters such as actual oscillation holographic parameters and negative slip amount of the oscillation table by effectively detecting the movement of the mold. The technicians can formulate the control strategy of the mould according to these actual parameters, and improve the output and quality of the product within a safe and reliable range.
The structure of the instrument
Continuous casting mold oscillation and deflection detection instrument is mainly composed of sensor system, sensor signal conditioning circuit, power supply circuit, synchronous data acquisition module, communication cable, and software data analysis system.
There are three axial acceleration sensors installed in the mold oscillation and deflection detection instrument, one of which is to detect the vertical oscillation signal (Y axis), and the other two are to detect the horizontal oscillation signal (X and Z axis). The signal obtained by the sensor is processed by the preprocessor and the preprocessing module. The oscillation signal and sensor status signal will be filtered and normalized, sent to the synchronous data collector for digitization and feature extraction, and the data is analyzed and processed by the master computer software to obtain various oscillation parameters and process parameters required by users.
Insulation resistance tester with absorption ratio embedded real-time industrial microcomputer operating system, ultra-thin wire-shaped sheets header with the perfect combination of dot matrix liquid crystal display, the instrument is with a variety of voltage output level (250V,500V,1000V,2500V,5000V,10000V), high capacity, strong anti-interference, the pointer and digital synchronous display, AC-DC dual-use, simple operation, automatic calculation of various insulation index (absorption ratio, polarization index), all measured characteristics with the anti-power-down function .
Light digital relay protection tester characteristics; 4/6/8 pairs of 100M Optical Fiber Communication Ethernet interface, can send and receive the sampling value of the IEC61850-9-1 / 2 frame format, Goose, IEEE-1588 packets; more support 24 sets of SV packets +64 groups of Goose packets simultaneously; 3/5 pairs of 2 ~ 10M fiber serial port, can send and receive IEC60044-7 / 8 FT3, national network expansion FT3, Xu Ji privately owned FT3 frame format sampling value " 12 road simulation small signal output, provides testing of protection devices input for small signals;
Frequency conversion series resonance test device is designed and manufactured for alternating-current withstand voltage test of Possessing a wider application scope, it is the ideal withstand voltage equipment for prefecture-level, municipal-level and county-level high-voltage test departements as well as power installation and repair & testing engineering units.
Frequency Conversion Series Resonance Test Device
(I) Technical index
1. Rated voltage:
2. Quality factor under full load in test of fire power generator: Q10 (relating to load)
3. Quality factor under full load in cable test: Q 30 (relating to load)
4. Quality factor under full load in test of main transformer: Q 30 (relating to load)
5. GIS, the quality factor under full load in switch test and other tests: Q 50 (relating to load)
6. Input power supply: single phase of 380V
7. Frequency adjustment range: 20Hz 300Hz
8. Accuracy of system measurement: 1.5
9. The unit possesses protective functions, such as over voltage, over current and zero start.
(II) Description for main configuration and technical data of equipment:
1. One set of variable-frequency power supply:
Rated power: 10kVA;
Input voltage: single phrase of 220V or three phase of 380V 10% and 45 65Hz
Output voltage: 0 400V adjustable
Output voltage frequency: 30 300Hz
0.1Hz adjustable stepping
Instability degree of frequency 0.02%
Output current: 0 25A
2. High-voltage resonane reactor (4sets in all): 27kV/1A
LAG-S200 Ladle Slag Detection System (Vibration Type)
Overview
The continuous casting vibration type ladle slag detection device is used to detect the slag content of the ladle nozzle in the steelmaking continuous casting process, so as to improve the cleanliness of the tundish molten steel and obtain the best yield of the ladle molten steel. The device adopts the principle of vibration detection.
The LAG-S200 continuous casting ladle slag automatic detection system after many years of research with many scientific research institutes, and fully combined with the actual situation on site. It has a real field application value as a continuous casting ladle slag automatic detection system.
The meaning of the system
1. Reduce the amount of tundish slag
2. Improve the purity of molten steel
3. Improve the life of the tundish
4. Reduce sliding nozzle erosion
5. Reduce nozzle blockage
6. Increase the number of continuous pouring furnaces
7. Reduce the amount of residual steel in the ladle when high-quality steel is casting
8. Improve the yield of molten steel
9. Improve the quality of continuous casting billets
In order to improve the purity of the molten steel in the tundish, and improve the quality of the casting billet, especially to improve the quality of the billet in the transition section, and reduce the amount of residual steel in the high-quality ladle, and prolong the life of the tundish lining, and increase the number of continuous casting furnaces, necessary to detect and control the slag in the later stage of continuous casting ladle casting.
The Working principle of the system
The LAG-S200 continuous casting ladle slag automatic monitoring system detects the slag state during the pouring process by receiving the vibration signal of the mechanical operating arm of the ladle nozzle. In the process of molten steel pouring, when molten steel flows through the long nozzle and pours into the tundish, the molten steel impacts the wall of the long nozzle and causes the vibration of the mechanical operating arm used to support the long nozzle. Since the specific gravity of the steelmaking slag is less than half of the specific gravity of the molten steel, it floats on the surface of the molten steel, and the steelmaking slag appears when the molten steel is about to be all poured. At this time, due to the high viscosity and poor fluidity of light steelmaking slag, the impact force of the mixed flow of molten steel and steel slag on the wall of the long nozzle is quite different from that of pure molten steel. The system mainly monitors the ladle slag of the continuous casting by measuring and analyzing the vibration difference of the mechanical operating arm.
The handheld roll gap checker is specially used to measure the length between spherical surface, arc surface and plane (or spherical surface). It is specially suitable for the opening adjustment of the roll gap of the metallurgical continuous casters in various specifications, because the roll gap checker has the advantages of high resolution, accurate measurement, stable data and easy to use. Because the opening accuracy of the roll gap checker will directly affect the quality of the casting block, this roll gap checker is an indispensable testing equipment in the continuous casting equipment, which can fully meet the needs of on-site installation testing and use process verification. When the hand-held roll gap meter smoothly passes through the gap between the guide rolls of the continuous casting machine, the upper measuring contact of the hand-held roll gap checker contacts the inner arc roll and the lower measuring contact touches the outer arc roll. The handheld roll gap checker is used in perpendicular to the roll diameter direction, during the pushing process, when the hand-held roll gap meter is in the tangent plane of the upper and lower rolls, the measured value is the smallest at this time, and this value is the roll gap measurement value. The design of the hand-held roll gap gauge ensures that the upper and lower contacts of the roll gap checker can smoothly pass the measured roll along a straight line during measurement.
During the measurement process, the roll gap measuring instrument automatically compares the measured values, and displays the minimum measured value on the instrument display interface, which is the current measured roll gap value.
The technical parameters
1. Measuring range of instrument type handheld roll gap checker: 180mm - 400mm (the range can be customized)
2. Measuring range of digital hand-held roll gap checker: 120mm - 400mm (the range can be customized)
3. Measuring range of hand-held thin slab roll checker : 60mm - 150mm (the range can be customized)
Insulating boots and gloves withstand voltage device is a power frequency power supply with low voltage working voltage of 220V/50Hz for insulating boots and gloves. According to the principle of electromagnetic induction, the input voltage is changed to the minimum value required for the test. high pressure. Insulating boots (gloves) withstand voltage test device generally consists of a special dedicated test box, an intelligent power frequency withstand voltage console, and a power frequency withstand voltage test transformer.
A special water tank can be customized according to needs to test 6-8 insulated boots or 6 insulated gloves at a time, and display the leakage current of the insulated boots or insulated gloves at the same time. The intelligent power frequency withstand voltage console is equipped with overcurrent protection and zero protection. Time protection and alarm function. The preventive voltage resistance test device for insulating boots and gloves is a special product developed and produced according to the needs of users according to the test procedures of insulating boots (gloves).
The selection has an automatic boost (buck) function, automatically reads the leakage current of each test product, the whole process is automatically completed, and the test data is automatically printed, which effectively solves the previous non-standard test methods, thereby simplifying .Simplifies the test procedure and improves the test speed. More reliable identification of parameters such as leakage current and power frequency withstand voltage of insulating boots (gloves). To ensure the safety of test personnel, it is an ideal pre-treatment of insulating boots (gloves) to protect power frequency withstand voltage test equipment.
Technical Parameters
Input voltage AC220V 50 Hz
Output voltage 0~30kV
Capacity 3kVA
Test number 3 pairs each time
Quality Gloves (insulating boots) test car: 80kg; power frequency withstand voltage test bench: 70kg
Features:
3D software support, 3D image soon construction
Windows XP ultrasound system, quick start up and running, convenient software updating, large capacity and strong stability
Backlight silica gel PBT keyboard, easy for darkroom operation
Auto generating the fetal growth analysis report, and Obstetrics and Gynecology, small parts, cardiology and urology reports, can connect with laser printer for A4 report printing.
Expanded port: Video port, S-Video port, RS-232 port, USB2.0 port, VGA port,DICOM3.0 port
Standard configurations: Main unit, 15 inch LCD screen with rocker, convex probe, laser printer, 3D software
Optional: linear probe, video printer, vaginal probe, puncture guide.