Product Introduction It is suitable for evaluating the insulation quality of high voltage transformergenenratorling-distance power cable and busbar under strong interference in the field of high-voltage substation and power plant.Specially used for 110KV and above large capacity transformer and long distance power cable power system Product Characteristics 1.Strict accordance with the safety standards for design with 5 range: 500V 1000V 2500V 5000V 10000V test up to 10T�©. 2.This instrument has the function of automatic calibration and calibrate precision automatly before test 3.Actual test object live voltage measurement functionmeasure leakage currentdischarge automatly. 4.automatic measure and remenber R15Sã??R60S ã??R10min valueAutomatic display polarization index (PI) induced electric absorption test values than (DAR)and test time. 5.Anti-jamming performance is superior the interference current reaches 600 mA still ensure accuracy of test instruments. 6.Automatic discharge:quickly discharge for capacitive test object by advanced high-voltage discharge technology and real-time measurement of discharge voltage (test voltage to 0v) . 7.powered by internal rechargeable lithium battery or ac power supply the real ac and dc dual use does not affect the test accuracy. 8.digital displayautomatic display battery level and undervoltage alarm protection function. 9.Short circuit protection short circuit condition will not burn out the instrument
Product description Single-phase standard power supply is suitable for power department, quality control department, research units, institution of higher learning, electric energy meter, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. It can be as single phase voltage source, current source and power source. Electrical parameters Electrical parameters Accuracy class 0.05%, 0.1% Power supply Single phase AC 85-265V, 50/60 Hz AC Voltage output Range 57.7V / 100 V / 220V / 380V, Switch automatically (max 500V) Adjustment resolution 0.01%, 0.1%, 1%, 10%, AC Voltage output Range 57.7V / 100 V / 220V / 380V, Switch automatically (max Adjustment resolution 0.01%, 0.1%, 1%, 10%, Accuracy 0.05% RG Stability Better than 0.01% RG/1min Distortion degree Better than 0.1% (not capacitive load) Load capacity 40VA Full load regulation rate Less than 0.01% RG Full load regulation time Less than 1ms Temperature drift 8 PPM C Long-term stability 60 PPM/year AC Current output Range Adjustment resolution Accuracy Stability Distortion degree Load capacity Full load regulation rate Full load regulation time Temperature drift Long-term stability 0.1A / 0.25A / 0.5A / 1A / 5A / 10A / 20A / 50A / 100A, Switch automatically 0.01%, 0.1%, 1%, 10%, 0.05% RG Better than 0.01% RG/1min Better than 0.1% (not capacitive load) 40VA Less than 0.01% RG Less than 1mS 8 PPM C 60 PPM/year