DTDL-8110 Cablefault Test Set is an integrated set of Cablefault Detection and Location Devices. It is applicable for many types of power cable, communication cable and optical cable. It can accurately measure the distance of cablefault and locate the fault point. The system includes: 1) DTDL-8110 Mainframe. 2) DTDL-8032R Receiver. 3) RF Inductive Tracking Rod. 4) Potential Difference Locating Rack with 2 pins. 5) AF Stethoscope and Headphones (for Listening mode). 6) Grounding Pin.
Tgs p/n cs & css (hc-49s&hc-49ss) Dim.(mm) 11.05x4.7xh Frequency 3.20000~100.0mhz Tol.: G¦10 ppm ~ G¦50 ppm Stability: G¦10 ppm ~ G¦50 ppm Drive level: 100 uw max. Aging: G¦5 ppm max.
Tgs p/n com75 ( smd osc 0705) Dim.(mm) 7.0x5.0x 1.75 Frequency 500khz~ 125mhz Main features: Stab.: G¦25ppm to G¦100ppm Supply voltage: 5.0v or 3.0v Output logic: ttl and cmos Rise and fall time: 6ns max. Symmetry: 45/55% Start-up time: 10ms max.
Product description Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard technical parameter 1. Temperature: 2. Relative humidity 3. Rated Primary Current:5-5000A 5A,1A 4.Rated secondary current:5 1A 5 Accuracy Class 0.05S 6. Allow long-term work under the rated current; More than120A across the core. Precautions: 1. The current of standard CT and tested CT must be the same in CT calibration. 2. Follow the given wiring diagram strictly. 3. Test whether the load box is accurate or not before calibrating the transformer. 4. Forbid secondary winding opening during the calibration. 5. Select demagnetization before calibration.The wiring diagram is shown in figure 5. Short out the secondary winding before cutting off the power when the demagnetization is finished. 6.Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Product Introduction Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer. Product Parameters Technical parameters Rated Capacity 80kVA rated voltage 160kV Adjustable inductance range 65~130H Rated frequency 50Hz Rated current 0.5A Adjustable gap range 0~300mm
Product description Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard technical parameter Temperature -5 40 Relative humidity 80% Rated Primary Current 5-5000A 5A,1A Rated secondary current 5A 1A Accuracy Class 0.05S Allow long-term work under the rated current; More than120A across the core. Precautions The current of standard CT and tested CT must be the same in CT calibration. Follow the given wiring diagram strictly. Test whether the load box is accurate or not before calibrating the transformer. Forbid secondary winding opening during the calibration. Select demagnetization before calibration.The wiring diagram is shown in figure 5. Short out the secondary winding before cutting off the power when the demagnetization is finished. Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Product Introduction AC and DC dual purpose AC and DC withstand voltage tester. The winding is theconcentric pagoda and multilayer cylindrical type low-voltagewinding in inner high-voltage winding in outside; Outer cover is portable which has characteristics such as volume smallness weight light the shape prettiness and move convenience and so on. xc control cabinet Technical Paramenters environment temperature 0 40 altitude 100m relative humidity 85% Main product specifications type specification capacity power source output operating mode Refer to the weight anthroposcopy V A V A XC-2 2 1 220 50 0-220 10 manual operation 14 XC-3 3 1 220 50 0-220 15 manual operation 16 XC-5 5 1 220 50 0-220 20 manual operation 18
Overview Microcomputer relay protection tester also known as three-phase microcomputer relay protection tester, three-phase microcomputer relay protection tester is a special power relay protection tester.Three-phase microcomputer relay protection tester has 4 phase voltage 3 phase current output, suitable for various types of relay protection device test.Three-phase microcomputer relay protection tester adopts high speed and high performance digital control processor as control microcomputer, and the software uses double precision algorithm to generate arbitrary high precision waveform of each phase.Because of the integrated structure, each part is closely combined, the data transmission distance is short, and the structure is compact.It overcomes the problem of low number of output waveform points caused by long data communication line and narrow frequency band in the measurement and control instrument directly controlled by laptop computer. Technical parameter : AC current output Output accuracy Phase current output (effective value) Three merge current output (effective value) 120A Phase electric length time allows work value (effective value) 10A Phase current maximum output power 420VA Maximum output power at the maximum output of three 900VA Working time is allowed when the maximum output of the three mesh is output 10s Frequency range (fundamental) 20 1000Hz Harmonics 1 20 times AC voltage output Output accuracy Level 0.2 Phase voltage output valid value 120V Line voltage output valid value 210V Maximum voltage output value 240V Phase voltage / line voltage output power 80VA /100VA Frequency range (fundamental) 20 1000Hz Harmonics 1 20 times
Specification: Measurement range : So2(micro-flow ndir):0-2000 ppm No(micro-flow ndir): 0-2000 ppm Co(micro-flow ndir): 0-5000ppml O2(electrochemistry):0-25% vol Resolution: So2/no/co:1 ppm, o2: 0.01% Precision:ía2% fs Response time:ín15s Dimension:rack type 19 inch 3u Weight:approximately 10kg 3u casing
Gas parameter Measurement principle: Micro-flow ndir : so2, no, co, co2 Electrochemistry: o2 Measurement range : So2:0-2000ppm No: 0-2000ppm Co: 0-5000ppm Co2:0-25% O2: 0-25% Resolution: So2/no/co: 1ppm Co2/o2: 0.01% Precision: So2, no, co, co2 : 1%fs O2: 2%fs Temperature parameter Measurement principle: Ambient temperature:thermistor Flue gas temperature: thermocouple Range: Ambient temperature :-10-100íµ Flue gas temperature : -10-600íµ Resolution: Ambient temperature 1íµ Flue gas temperature 1íµ Precision: Ambient temperature ía1íµ Flue gas temperature ía2íµ Pressure parameter: Measurement principle: Diff. Pressure: silicon diff. Pressure chip Ambient pressure: silicon pressure chip Range: Diff. Pressure:-50hpa ...+50hpa Ambient pressure: 70kpa...120kpa Resolution: Diff. Pressure: 1pa Ambient pressure: 0.01kpar Precision: Diff. Pressure: ía2pa or 5%rel Ambient pressure: ía0.5 kpa or 2 % rel.
Specification: Measurement range ch4:0-100%, co2:0-50%, o2:0-25%, h2s:0-9999ppm Precision:co2/ch4:ía2%, o2:ía3%, h2s:ía4% Resolution:ch4/co2/o2:0.01% , h2s: 1 ppm Respond time:less than 20s Warm up: 10min Output: rs232 Power: ac220vía10% 50hzía1hz Weight: 10kg Dimension: rack type19 inch 3u 3u casing
Electronic batteries - er14250(h, m), er14505(h, m), er14335(h, m), er18505(h, m), er26500(h, m), er34615(h, m), cr123a, cr14250, cr14505, cr14335, cr17335, cr18505, cr18650, cr2032, cr26500, , er14252, er20505, er32100, er3265, er14505s, er17335s, er26500s, er34615s, er9v, cr9v.
Product Introduction: Lightning Protection Element Tester is suitable for testing the DC parameters of over-voltage protection components such as zinc oxide surge arresters (varistor) cermet two three-electrode discharge tubes and vacuum lightning arresters. Product Parameters: Varistor measurement Technical index Measuring range Maximum error Test Conditions
Overview In the process of semi finished and finished production of power transformers, before the newly installed transformers are put into operation and according to the state Grid's preventive test rules, it is required to test the transformer's turn ratio or voltage ratio regularly.The traditional variable ratio bridge operation is tedious, the reading is not intuitive, and the necessary conversion, the test result is only one phase change ratio value.The transformer transformer ratio tester overcomes the shortcomings of the traditional transformer ratio bridge test, the screen uses a large screen high resolution LCD screen, convenient to use in the field, with Chinese menu prompt function, simple and intuitive operation, a complete three phase change ratio test, test speed, high accuracy. Technical parameter range 0.910000 The accuracy of reading 0.1 2 words or equal to 500 reading 0.2 2 words 500 3000 Reading 0.3 2 words 3000 The resolution of the 0.9 9.9999 0.0001 100 999.99 0.01 10000 and above 1 10 99.999 0.001 1000 9999.9 0.1 Working power supply AC220V 10 50Hz Instrument weight 3.5kg The use of temperature 10 50 Overall dimensions 260mm l 200mm W 160mmH Relative humidity 90 no dew Feature Full three phase sinusoidal inverter output, the output voltage is automatically adjusted, with soft start, soft stop function, so the test speed is fast, high precision Three-phase transformer, single-phase transformer, PT, Z type transformer ratio, group, polarity test function Blind test function, that is, variable ratio and group test when high and low pressure connection mode is not known; CT variable ratio polarity test function Angle difference test function for single-phase test Tap position can be tested up to 197
Introduction The SF6 gas comprehensive instrument is a three-in-one tester that integrates, concentration, and main crystallization measuring instruments. It concentrates the achievable capabilities into one and completes three functional tests at a time, which greatly reduces the gas emissions in the equipment and effectively protects the environment. , Pollution, while reducing the user's workload and improving work efficiency. It is because the sensor of Finland Vaisala is used; the SF6 gas comprehensive supplementary instrument has sufficient performance, and it uses an efficient absorption sensor. The special instrument adopts the sensor of German HNP; some products adopt the special sensor of imported American Dekang SF6. The SF6 integrated equipment display adopts a large-screen Chinese display, real-time various parameters, intelligent and intelligent operation, massive information, and dual-use rechargeable batteries. Energy saving technology, energy saving and environmentally friendly instruments. The SF6 comprehensive tester adopts the sensor, sensor, SOH2S, CO and other sensors of , and adopts the thermal conductivity type of Sensors and R&D sensors; more advanced ARM development technology, quality sensors, sensors and other precision sensors, equipped with sensors and sensors are more realistic, more simultaneous, and manufactured. The tester uses a color screen screen display, friendly interface, and easy to operate. This type of comprehensive tester uses reliable imported sensors as sensitive components, and at the same time integrates real time measurement, curve display, power management, time system, file system, data query, data understanding and other update functions, and integrates advanced sensor technology. And information technology, humanized operation information technology, humanized operation and perfect functions, you can learn her ability and perfection in printing.
Product description The Single phase capacitance and inductance tester is specially developed for the problem of measuring the capacitance value of the capacitor on the substation. Technical parameters Instrument measurement range and accuracy Capacitance measurement Measurable capacitance range 0. 1 F 3,300 Measurable capacity range 5 20,000kvar Measurement accuracy 1.0 readings 0.02 F Resolution 0.001 F Current measurement Current measurement range 0 20A Measurement accuracy 3.0 readings 0.05A Resolution 0.01A Inductance measurement Inductance measurement range small inductance mode 0.1mH 5mH large inductance mode 5 mH 50H Inductive reactance measurement range 50m 20K Measurement accuracy 3.0 readings 0.05mH Resolution 0.01mH Resistance measurement Resistance measurement range small resistance mode 50m 1
Overview The transformer integrated test system complies with GB1094, GB / T4776, GB / T5169 and other relevant national standards. With the increase in transmission and electrical power generation and the continuous increase in power grids, the successful transformation of the national city network, the farnet, and the number of online quantities and capacity of power transformers are increasing. Technical parameter: Equipment measurement range and precision Voltage metering range: 50V 500V Voltage metering accuracy: 0.2% Current metering range: 0.1a 5a (can be 0.1A 1A) Current metering accuracy: 0.2%; Power frequency withstand voltage test Leak current: 400mA Input current monitoring instrument Monitoring range: 200A Function: Equipment failure automatic detection function, automatically detect peripherals, such as: the voltage regulator is zero, etc .; Test item: no-load loss measurement, no-load current percentage (automatic conversion to the value of the rated voltage), load loss measurement, the impedance voltage percentage (automatic conversion to the rated current reference temperature) Automatic measurement (voltage ratio measurement, connection group label test), external pressure test (power frequency withstand voltage test), induction pressure test (multiplier multiplier test), insulation resistance measurement, lightning shock test, insulation Oil test (breakdown voltage, flash point, acid value, volume resistivity, moisture, etc.), local discharge test, temperature rise test
Product description Current transformer field tester was developed with high-end testing technology, large-scale electronic circuit design and accord with national related protocol . It has solved the problem of big working intensity,trival operation while on-site test of current transformer, voltage transformer. Meanwhile the product has a reliable performance,and the function is strong. Technical index
Product description Anti Emulsification performance automatic tester meets the requirement of GBT 7305-87 and GBT 7605-87, which adopts 32-bit high-performance microprocessor, high definition color touch screen and digital PID control algorithm to achieve high accuracy of temperature control, good repeatability, automatic lifting of stirrer, simultaneous test of four samples, smart storage and convenient check of test result. Technical index Temperature measurement Platinum resistance Water bath temperature 54 Room temperature 100 can be set arbitrarily Control accuracy 0.1 Stirring speed 1500 15 rmin Number of cylinders 4 Self-check function Stirring device lifting and rotating Display High definition color touch screen Power supply AC 220V 22V Power 1800VA Frequency 50Hz 2.5Hz Ambient temperature 10 35 Ambient humidity 85 Weight about 24kg Profile size 358mm 302mm 858mm Anti-emulsification performance automatic tester
PCB connectors, pin header, female header, box header, ejector header, IC socket, machined pin & female header, IDC socket, dip plug, micro match, PLCC, sata, cable & cable assembly, terminal blocks.