Product Introduction:
Lightning Protection Element Tester is suitable for testing the DC parameters of over-voltage protection components such as zinc oxide surge arresters (varistor) cermet two three-electrode discharge tubes and vacuum lightning arresters.
Product Parameters:
Varistor measurement
Technical index Measuring range Maximum error Test Conditions
Microcomputer relay protection tester also known as three-phase microcomputer relay protection tester, three-phase microcomputer relay protection tester is a special power relay protection tester.Three-phase microcomputer relay protection tester has 4 phase voltage 3 phase current output, suitable for various types of relay protection device test.Three-phase microcomputer relay protection tester adopts high speed and high performance digital control processor as control microcomputer, and the software uses double precision algorithm to generate arbitrary high precision waveform of each phase.Because of the integrated structure, each part is closely combined, the data transmission distance is short, and the structure is compact.It overcomes the problem of low number of output waveform points caused by long data communication line and narrow frequency band in the measurement and control instrument directly controlled by laptop computer. Technical parameter : AC current output Phase current output (effective value) 040A Three merge current output (effective value) 0120A Phase electric length time allows work value (effective value) 10A Phase current maximum output power 420VA Maximum output power at the maximum output of three 900VA Working time is allowed when the maximum output of the three mesh is output 10s Frequency range (fundamental) 201000Hz Harmonics 1 20 times AC voltage output Output accuracy Level 0.2 Phase voltage output valid value 0120V Line voltage output valid value 0210V Maximum voltage output value 0240V Phase voltage / line voltage output power 80VA /100VA Frequency range (fundamental) 201000Hz Harmonics 1 20 times volume and weight Dimensions 365*300*165MM Stand-alone weight 15.5KG
Overview Microcomputer relay protection tester also known as three-phase microcomputer relay protection tester, three-phase microcomputer relay protection tester is a special power relay protection tester.Three-phase microcomputer relay protection tester has 4 phase voltage 3 phase current output, suitable for various types of relay protection device test.Three-phase microcomputer relay protection tester adopts high speed and high performance digital control processor as control microcomputer, and the software uses double precision algorithm to generate arbitrary high precision waveform of each phase.Because of the integrated structure, each part is closely combined, the data transmission distance is short, and the structure is compact.It overcomes the problem of low number of output waveform points caused by long data communication line and narrow frequency band in the measurement and control instrument directly controlled by laptop computer. Technical parameter : AC current output Output accuracy Phase current output (effective value) Three merge current output (effective value) 120A Phase electric length time allows work value (effective value) 10A Phase current maximum output power 420VA Maximum output power at the maximum output of three 900VA Working time is allowed when the maximum output of the three mesh is output 10s Frequency range (fundamental) 20 1000Hz Harmonics 1 20 times AC voltage output Output accuracy Level 0.2 Phase voltage output valid value 120V Line voltage output valid value 210V Maximum voltage output value 240V Phase voltage / line voltage output power 80VA /100VA Frequency range (fundamental) 20 1000Hz Harmonics 1 20 times
Overview Light digital relay protection tester characteristics 4 6 8 pairs of 100M Optical Fiber Communication Ethernet interface, can send and receive the sampling value of the IEC61850 9 1 2 frame format, Goose, IEEE 1588 packets more support 24 sets of SV packets 64 groups of Goose packets simultaneously 3 5 pairs of 2 10M fiber serial port, can send and receive IEC60044 7 8 FT3, national network expansion FT3, Xu Ji privately owned FT3 frame format sampling value 12 road simulation small signal output, provides testing of protection devices input for small signals Technical parameter Fiber Ethernet port 4 6 8 pairs 100 Mbits S, ST, Mode, 1310nm IEC61850 9 1 2 Le, Goose, IEEE-1588 Send dispersion
Overview Light digital relay protection tester characteristics; 4/6/8 pairs of 100M Optical Fiber Communication Ethernet interface, can send and receive the sampling value of the IEC61850-9-1 / 2 frame format, Goose, IEEE-1588 packets; more support 24 sets of SV packets +64 groups of Goose packets simultaneously; 3/5 pairs of 2 ~ 10M fiber serial port, can send and receive IEC60044-7 / 8 FT3, national network expansion FT3, Xu Ji privately owned FT3 frame format sampling value " 12 road simulation small signal output, provides testing of protection devices input for small signals; Technical parameter: Fiber Ethernet port 4/6/8 pairs 100 Mbits / S, ST, Mode, 1310nm; IEC61850-9-1 / 2 / Le, Goose, IEEE-1588; Send dispersion:
Product Introduction SF6 intelligent micro water quality tester is developed and designed according to the national power industry standard DL t506 2007 insulation gas humidity measurement method for sulfur hexafluoride electrical equipment and adopts the imported high precision dew point sensor and new digital circuit control technology. It is a high-precision intelligent instrument to measure the trace moisture content in SF6 gas. This instrument adopts intelligent self calibration technology wide measurement range fast response high accuracy good linearity dynamic display of measurement curve. At the same time the instrument also has an automatic dryer which can greatly reduce the measurement time. Technical Parameters Measuring range Dew point value 80 20 Moisture content 0 19999uLL Accuracy of measurement 0.5 60 20 1.0 80 60 The resolution of the Dew point value 0.1 Moisture content 1uLL Response time 20 0.1mpa 63 needs 5s 90 needs 45s 60 20 63 needs 10s 90 needs 240s 20 60 Sampling flow 0.6L min 20 Pressure range 01.0Mpa The use of temperature 20 60 Environmental humidity 0 100 RH Storage temperature 20 80 Charging time 4 hours The whole machine size 250 150 300mm3 The weight of The machine 3.5kg
This product is portable design,used in field to check watt-hour meter error. Accuracy class:0.05. 6.4inch TFT COLOR LCD measured CT variable ratio 0-600V/1MA-12A Check wiring and calculation electricy of compensation.
To test the tensile strength, peeling strength, heat sealing strength, tearing strength, piercing strength, compression strength, bending strength, and cutting strength of the plastic film, composite film, tape, soft packaging material, rubber sheets, paper, non-woven fabrics, and other packaging materials, widely used in industries of plastic films, food, pharmaceuticals, inspection agency, research institute, college and so on.
Product description The Transformer short circuit impedance tester comes with an adjustable power output. Regardless of single phase or three phase transformers, only one connection is required, and the instrument can complete the measurement of all winding pairs. The test and connection are simple. Main technical indicators and conditions of use Measurement accuracy voltage, current 0.2 level Power COS 0.1 0.5 grade, COS 0.1 1.0 grade Impedance COS 0.1 0.5 grade COS 0.1: 1.0 grade Voltage measurement range AC 3V 300V Internal power output range voltage 0 250V, current 0 10A Current measurement range AC 0.2A 20A Working temperature 10 50 Working humidity 0 80 Working power supply AC220V 10 50Hz 1Hz Dimensions 360mm 220mm 150mm Weight of the instrument 20Kg Transformer Short circuit Impedance Tester
Product description 3 phase capacitance and inductance tester is developed for the problems of capacitance value, and it solves the following problems Field measurement capacitor needs dismantling cables, not only the big workload but also easy to damage the capacitor. Low capacitance meter output voltage causes the fault detection rate is low. The instrument has characteristics of small measured workload, fast and simple, stable performance, high measurement accuracy, high fault detection, etc. Reactor inductance measurement. Technical parameters Working power supply Rated voltage power frequency of 220 V10 The rated frequency 50Hz The rated output 2V 20V 500VA Equipment normal working conditions Environmental temperature 10 50 Relative humidity 90 Display and print mode LCD display with Chinese characters Panel high speed printer Shape weight 370 260 220 mm 15 kg 5. Work principle as shown in figure 1 3 phase capacitance and inductance tester Feature The inductance capacitance tester adopts the bridge circuit structure, the standard capacitor and tested capacitor as two arms of the bridge circuit. When conducting the capacitor capacitance value measurement, test voltage applies on the standard capacitor and tested capacitor at the same time. Processor obtains capacitance value of tested capacitor by sensors with acquisition the current signals through the two capacitors after processing. Due to adopting the standard capacitor, tested capacitor synchronous sampling technology, it may not affected by the power supply voltage fluctuation; Combined with the measurement process is fully automatic, which avoids the error due to manual operation, so it has the characteristics of good stability, good repeatability, accurate and reliable, the machine has tested object automatic identification and short circuit protection function.