Features Rugged construction providing shock, dust and moisture resistance Dual monitor position with automatic image orientation Automatic arc calibration and iber identiication User-selectable iber clamping method sheath clamp or fiber holders Auto-start tube heater feature Color LCD display with anti-relective coating for excellent visibility in bright sunlight Simultaneous battery charge and splicer operation Long life battery (up to 160 splice/heat cycles per charge) Detachable work table incorporated into the transit case Data and video download software and splicer upgrade software included; software upgrades through PC application via the internet Green friendly RoHS & WEEE compliant Specifications Model FSM-60S Applicable Fibers SM(G.652),MM(G.651), DS(G.653),NZ-DS(G.655) Cladding Diameter 80 um to150 um Coating Diameter 100 um to 1000 um Fiber Cleave Length 8 to 16mm with 250um coating diameter, 16mm with 900um coating diameter Typical Average Splice Loss 0.02dB with Sm, 0.01dB with mm, 0.04dB with DS, 0.04dB with NZDS Splicing Time Typical 9 seconds with standard single-mode fiber Arc Calibration method Automatic, real-time and by using results of previous splice when in AUTO mode, manual arc calibration function available Splicing modes 100 preset and user programmable modes Splice Loss Estimate Based upon dual camera core alignment data Storage of Splice Result Last 2000 results to be stored in the internal memory Fiber Display X or Y, or both X and Y simultaneously. Front or rear monitor display options with automated image orientation Magnification 300X for single X or Y view, or 187X for X and Y view Viewing method Dual cameras with 4.1 inch TFT color LCD monitor Operating Condition 0 to 5,000 m above sea level, 0 to 95 % RH and -10 to 50°C respectively mechanical Proof Test 1.96 to 2.25N Tube Heater Built-in tube heater with 30 heating modes; auto-start function Tube Heating Time Typical 30 seconds with FP-03 sleeve, 35 seconds with FP3(40), 35-55 seconds with Fujikura micro sleeves Protection Sleeve Length 60mm, 40mm, micro Splice Cycles with Battery Typical 160 cycles with power save functions activated Power Supply Auto voltage selection from 100 to 240V AC or 10 to 15V DC with ADC-11, 13.2V DC with BTR-08 battery Terminals USB 1.1 (USB-B type) for PC communication. Mini-DIN (6-pin) for HJS-02/03 and SH-8 tube heater Wind Protection Max. wind velocity of 15m/s. (34 mph) Dimensions (W × D × H ) 136 × 161 × 143 mm; 5.3 × 6.3 × 5.6 inches Weight 2.3 kg (5.1 lbs) with AC adapter; 2.7 kg (5.9 lbs) with BTR-08 battery.
Features Fiber core can be display clearly Single x or y view and x & y view simultaneously Auto check quality of , cleaved end face Auto select best splicing program 9 seconds splice time and 30 seconds heat time Small bulk and light weigh 5 inch color lcd monitor with clear digital image display Simple operation menu Specifications ModelKl-280 Applicable fibersSm(itu-t g.652), mm(itu-t g.651), ds(itu-t g.653), nzds(itu-t g.655) Fiber cleaved length8~16mm(coating diameter: 250µ,m) 16mm(coating diameter: 250 ~ 1000µ,m) Fiber diameterCladding diameter: 80 ~150µ,m coating diameter: 100~ 1000¦ìm Fiber countSingle Fiber aligning method Core , aligning Return loss>60db Actual average splice loss0.02db(sm), 0.01db(mm), 0.04db(ds), 0.04db(nzds) Splicing modeAuto Splicing mode12(templet), 188(user) Typical splicing timeTypical 9 sec, with standard sm fiber Protection sleeve length60mm, 40mm and a series of micro sleeves Storage of splice result5000 results, 3 parameter per result Tension test2n Fiber display and magnification400x(x or y view), 200x(x and y view) Tube heating timeTypical 30 sec Electrode life2500 No.Of splice/heating with batteryTypical 130 cycles (splice/tube heat) with inner li-battery Display screen5 inch color lcd monitor Image change overThe fiber image is turned upside down TerminalsRs 232 Operating condition0 ~ 5000m above sea level, 0 ~ 95%rh and -10 50c, respectively, max. Wind velocity of 15m/s Power supplyAc 100-240v with ac adapter,inner li-battery(6600mah) Dimensions150mm(l) x150mm (w) x160mm (h) Weight3.52 kg including battery.
Features Color LCD monitor & 256 magnification Compact & light weight Reversible monitor with control panel on each side Max. Wind velocity of 15m/s. 8 sec. Splice time, 40 sec. Tube-heat time Simultaneous x and y views Large capacity internal battery System test ensures the best working condition User programmable Auto check fiber end face Auto calibrate parameters Store 8000 groups of splice results Multiple language options Specifications ModelDvp-730 Applicable fibersSm, mm, ds, nz-ds, edf Cladding diameter100 to 150um Coating diameter100 to 1000um Fiber cleaved length8-22mm (standard) Splicing modeAuto & manual Average splice loss0.02db(sm), 0.01db(mm), 0.04db(ds), 0.04db(nzds) Return loss 60db Environment conditions-25-+50(operation temperature), 0-95%rh(humidity), 0-5000m (altitude) Storage environment-40-+80(temperature), 0-95rh (humidity) Protection sleeve length20mm, 40mm, 60mm Tension test2.0n (standard) LanguageEnglish, chinese, korea, russian, spanish etc. InterfaceRs232 interface & video output Power supplyAc adaptor: 85-260v input voltage Internal battery: 12v voltage, 10ah, up to 200 times of continuous splices and heatsdc adaptor: 12v voltage, optional multipurpose external battery Dimensions170(w)140(h)170(d)mm Weight3.3kg.
Fiber patch cord Fiber optic accessories.
Steel cable reel.
Model: gztgl-12 Fiber diameter: 10.0mm Fiber material: pmma Cable diameter: 12.0mm Cable material: transparent pvc Solid core side glow cable is produced by jacketing with transparent pvc cover for uv protection. 100m/spool
Fiber optic patch cord Applications 1. CATV 2. Metro 3. Test equipment 4. Active device termination 5. Local area networks (lans) 6. Premise installations 7. Telecommunication networks 8. Data processing networks 9. Wide area networks (wans) Features 1. Low insertion loss and high reflection loss 2. Good durability 3. Compliant standard: IEC & ROHS 4. Good exchangeability 5. High temperature stability 6. Customization, I. E.: print company name on the connector and adapter. 200 piece per carton, 0.0587 cbm per carton 12kg per carton.
Features: 1. FTTH project usable 2. Field installable 3. Fast, easy, accurate 4. Cost effective 5. Portable 6. Installation less than 2 minutes 7. Reliable and superior optical performance 8. Cable Tensile test complies with Telcordia GR-326-CORE Application: 1. Distribution frames 2. Maintenance or emergency restoration of fiber networks 3. Patch panels 4. FTTH Outlets 5. Field word.
Features: Uitra-end insertion loss and associated loss of polarization Goodspectral uniformity Wide wavelength bandwidth A wide range of working environment High reliability Small size Applications: Can be widely used for FTTX Passive Optical Network (OPN) Cable TV Network (CATV) Other optical signal splitter system Standard compliance: Telcordia GR-1209-CORE Telcordia GR-1221-CORE YD/T1117-2001 Performance Index Type Unit 1 X 2 1 X 4 1 X 8 1 X 16 1 X 32 1 X 64 Optical Fiber diameter um 9/125 um¡¨º¡¡ìsmf-28¡¨º© wavelength nm 1260~1620 Insertion Loss dB ¡¨º¼3.8 ¡¨º¼7.3 ¡¨º¼10.6 ¡¨º¼13.7 ¡¨º¼16.9 ¡¨º¼21 Uniformity dB ¡¨º¼0.6 ¡¨º¼0.8 ¡¨º¼1.0 ¡¨º¼1.4 ¡¨º¼1.6 ¡¨º¼1.9 PDL Loss dB ¡¨º¼0.20 ¡¨º¼0.20 ¡¨º¼0.30 ¡¨º¼0.30 ¡¨º¼0.30 ¡¨º¼0.35 Directivity dB ¡¨º¾55 Return Loss dB ¡¨º¾50 Operation Temperature ¡æ -40~ +85 Storage Temperature ¡æ -40 ~ +85 Type Unit 2X 2 2 X 4 2 X 8 2X 16 2 X 32 2 X 64. ABS box.
BV electirc cable (60227 IEC 05) 1) Conductor: Copper (70¡ã C single core solid) 2) Insulation: PVC 3) Sheathed: Non 4) Rated voltage (U0/U): 300/500V 5) Standard: IEC60227-2003 or as per the customers' requests 6) Purpose: For internal wiring 7) The max continuous operating temperature of the conductor: 70¡ã C 8) The ambient temperature for the cable installation: 0¡ã C 9) The bending radius of the cable: (D=cable outer diameter, R=bending radius) A. D 25mm, R 4D B. D>25mm, R 6D" 10) Specifications & Technical Data : Nominal cross- section Con- ductor Type Insulation Thickness Average Overall Diameter Approx Weight Max Conductor Resistance ¦¸ /km Min Insulation Resistance mm 2 mm mm kg/km without coat metal coat M¦¸ /km 0.5 1 0.6 2.4 8.08 36 36.7 0.015 0.75 1 0.6 2.6 10.55 24.5 24.8 0.012 1 1 0.6 2.8 13.28 18.1 18.2 0.011 HS Code: 8544492100 Productivity: 600km/Month Unit Price: Negotiable Shipment Terms: FOB Payment Terms: L/C,T/T,negotiation Minimum Order: 1000 Meter Price Valid Time: From Jan 09,2012 To Jan 09,2013 Insulation Material: PVC Conductor Type: Stranded Conductor Material: Copper Application: Inner House Wiring Type: Insulated Export Markets: North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe. 100m/roll 3roll/bags.
Material: UL Nylon6/6; Neoprene for seal insert, with nut Color: Black, gray, light gray Protection: IP68 Temp. Resistance: -300--80 degrees; Short time 140 degrees suggested clearance hole for non-threaded mounting. Depend on the products.
Specifications: 1) UTP Cat5, Cat5e cable, utp Cat6 cables are available 2) CCC,CE,CB,RoHS approved 3) Sale in Asia,Europe,Africa etc Structure: 1. Conductor: Material: solid or stranded copper Diameter: 23AWG Construction 1/0.57,0.02mm 2. Insulation: Material: HDPE Thickness: 0.24,0.05mm Diameter: 1.04,0.06mm Color: optional Elongation rate: Min.300% Tensile strength: Min.1.22kg/mm2 3. Jacket: Material: PVC Thickness: average:0.50mm Min. at any point:0.40mm Diameter: 6.3,0.3mm Color: to your option Elongation rate: Min.125% Tensile strength: Min.1.41kg/mm2 4. Rip cord& meter mark: optional 5. Standards: CE, CB,CE,ROHS, ISO 9001:2000,IEC Application: 1) Data transmission cable for structure laying electric wires 2) For figure, voice, data and video signal transmission 3) Suitable for all of D-level lines and Cat6 application 4) ISDN, 10M Ethernet, 100M speed Ethernet, KM Ethernet, 4/16Mbit/s Token-Ring, TP-PMD/TP-DDI 125Mbit/s, ATM 155Mbit/s. Carton.
Specifications: 1) Utp Cat5, Cat5e cable, utp Cat6 cables are available. 2) CCC, CE, CB, RoHS approved. 3) Sale in Asia,Europe,Africa etc. Structure: 1. Conductor: Material: solid or stranded copper Diameter: 23AWG Construction 1/0.570.02mm 2. Insulation: Material: HDPE Thickness: 0.240.05mm Diameter: 1.040.06mm Color: optional Elongation rate: Min.300% Tensile strength: Min.1.22kg/mm2 3. Jacket Material: PVC Thickness: average:0.50mm Min. at any point:0.40mm Diameter: 6.30.3mm Color: to your option Elongation rate: Min.125% Tensile strength: Min.1.41kg/mm2 4. Rip cord& meter mark: optional 5. Standards: CE, CB,CE,ROHS, ISO 9001:2000,IEC Application: 1) Data transmission cable for structure laying electric wires 2) For figure, voice, data and video signal transmission 3) Suitable for all of D-level lines and Cat6 application 4) ISDN, 10M Ethernet, 100M speed Ethernet, KM Ethernet, 4/16Mbit/s Token-Ring, TP-PMD/TP-DDI 125Mbit/s, ATM 155Mbit/s. Standard Lot Size
Conductor: Plain annealed flexible copper complying with BS6360, class 5 Insulation: PVC (polyvinyl chloride) Outer sheath: PVC (polyvinyl chloride). Color: Grey Voltage Range: 300/500 volts, Test 3000 volts Core Identification: Black cores with white numbers with green/yellow core. Operating temperature:- 20° C to + 70° C in fixed condition, - 5° C to + 70° C in mobile condition. Bending Radius:10 x Overall Diameter. The type flexible control cable, sometimes referred to as PVC/PVC control cable is ideal in fixed and mobile conditions. For use as a measuring, control and signal cable for the machine tool industry, plant construction, heating and air conditioning. 100m/roll.
Conductor: Bare stranded copper, IEC 60228, Class 5. Insulation: PVC (polyvinyl chloride) Outer sheath: PVC (polyvinyl chloride). Screen: Polyester tape, TWCB (Tinned Wire Copper Braid) Operating temperature: - 40° C to + 70° C in fixed condition, - 15° C to + 70° C in mobile condition. Bending Radius:15 x Overall Diameter. Flexible data transmission control cable with a Tinned Copper Wire Braid (TWCB). Used in electronic control systems, in voice frequency, signal and data transmission. LiYCY (CY) can be used as a connection cable in office machinery and measurement devices. Suitable for fixed and flexible applications with unrestricted mobility, without forced movement control and without exposure to tensile load. Because these cables have a copper screening they are ideally suitable for interference free transmissions. 100m/roll.
Voltage rating: 300/500V Application:For industrial and wiring installation in air or in cable management systems, embedded in masonry or cement. Not suitable for laying in ground. Construction:Solid or stranded plain copper conductors to VDE0295. PVC insulation, PVC sheath. Insulation colours: Three Core: Green/Yellow, Blue, Brown. Sheath colour: Grey Minimum bending radius: 4D Maximum conductor temperature: 70C. 100m/roll, roll in carton.
Application: Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors. Standards: Generally to BS6500, VDE0250 Conductor: Class 5 flexible plain copper conductors Insulation and sheath: PVC (Polyvinyl Chloride) Sheath Colour: Grey Voltage Rating: 300/500V Temperature Rating:Fixed: -35C to + 70CFlexing: -5C to + 70C Minimum Bending Radius:10 x overall diameter Core Identification: Black with White numbers. (3 cores and above to include Green/Yellow). Coloured cores available. RoHS Compliant. 100m/roll.
Technical Information Voltage Working : 300 / 500V to BS7919 & BS6500 Temperature range : Flexing : -25oC to +60oC Static : - 40oC to + 60oC Bending radius Flexing : 15 x cable diameter Static : 6 x cable diameter Stranding of fine copper wires plain or tinned Rubber insulation :Colored cores acc. to VDE 0293 More than 2 cores with one green / yellow earth conductor. Conductor Identification: Two Core - Brown and Blue Three Core - Brown, Blue and Green / Yellow Four Core - Brown, Grey, Black and Green / Yellow Five Core - Brown, Blue, Grey, Black and Green / Yellow Application of H05RR-F: For connection of electrical appliances when exposed to low mechanical strain in household, offices and for light utilities. Anywhere where there is minimal physical damage expected. 100m/roll.
Fiber optical cable. Tray 100 100 pcs 13.5*27*3 cm Inner box 20 tray/box 2000 pcs 29*29*22 cm Outer box 2 inner box/outer box 4000 pcs 60*31*25.8 cm.
PVC Insulated & Sheathed Power Cables Standards: IEC60502, GB/T12706-2008 Application: It is suitable to be installed in duct, tray or direct burial, with rated voltage of U0/U (0.6/1KV) for transmitting electricity. Service Conditions: 1. Regular nominal cross-sectional areas: 1.5 mm2, 2.5 mm2, 4 mm2, 6 mm2, 10 mm2, 16 mm2, 25 mm2, 35 mm2, 50 mm2, 70 mm2, 95 mm2, 120 mm2, 150 mm2, 185 mm2, 240 mm2, 300 mm2, 400 mm2, 500 mm2, 630 mm2, 800 mm2, 1000 mm2, 1200 mm2 2. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will not be affected by eciencies in the installation.