Please click here to check who's online and chat with them.

Find Verified Temperature Controllers Indicators Suppliers, Manufacturers and Wholesalers

Top Supplier Cities : Shenzhen   Guangzhou   Shanghai  
Jul-20-06
 
More than 30m communicating distance in room.

Ot protocol

It is widely used for temperature control on domestic appliance such as air-condition, wall hung boiler(combine boiler), etc.
Weekly programmable time zone
Energy saving/cost saving
6 programmable time zone per day
Winter/summer mode
6 different programs to satisfy different requirements
Rf wireless connection,no wire needs to connect to the room thermostat
2 programmable modes.
Jul-03-12
 
Thermostat

Detailed screw type bimetal thermostat description
1:auto reset
2:cremis shell
3.6.3*0.8 terminal
4:CQC UL VDE TUV SGS

Detailed brass screw bimetal thermostat description

fixation of the working temperaturing
reliable snap action
perdurable
less radio interference

Technical parameters:
Electrical parameters: 1)CQC,VDE,UL,CUL AC250V 50~60Hz 5A/10A/15A (Resistance load)
2)UL AC125V 50Hz 15A (Resistance load)
2.Action temperature range: 45~160 (Optional); temperature accuracy:
3.Recovery and action temperature difference: 8~100 (Optional)
4.Connection method: Insert the terminal 250# (bending angle: 0~90deg optional); Insert the terminal 187# (bending angle: 0~90deg optional; thickness: 0.5, 0.8mm optional)
5.Lifespan: over100,000 times
6.Electrical strength: No spark or breakdown for 1min at AC 50Hz 1800V
7.Contact resistance: less than 50m
8.Insulation resistance: less than100M
Junction method: Constant-closed: the contact point disconnects when temperature rises; and contact point connects when temperature falls;
Constant-opened: the contact point connects when temperature rises; and contact point disconnects when temperature falls.
10.Casing protective class: IP00
11.Grounding method: Connection is made between the metal casing of the temperature controller and the metal part of the grounding device.
12.Installation method: installed for KI031 series: general moving ring, mini round moving ring, flat moving ring general aluminum cover with mounting hole, extra length aluminum cover with mounting hole


Structure and application:
KI-32 serial products are the temperature controllers taking bimetallic strip as the temperature-sensing unit. In case of normal operation the electrical appliance, the bimetallic strip is in a free state; the contact point is in a state of close/open. When the temperature reaches the action temperature, the bimetallic strip performs quick action generates caused by internal stress due to heating; open/close the contact point; disconnect/connect the circuit; thus, the temperature is in control. When the electrical appliance is cooled to the recovery temperature, the contact point automatically opens/closes to recover normal operation state.
Widely used in electrical heating appliances like water dispenser, water heater, sandwich bread baker, dishwasher, dryer, sterilizing cupboard, micro-wave oven, electric heating coffee pot, electric cooker, refrigeratory, air-conditioner, laminator, heater of auto seat.


Characteristics:
Stable performance, high accuracy, small size, lightweight, high reliability, long lifespan, less interference to radio

Precautions:
1.When adopting contact temperature sensing installation, the surface of the metal cover is required to be securely contacted with the installing surface of the controlled device. For ensuring the temperature sensing effect, it is required to coat thermal conductive grease or other similar thermal conductive medium on the surface of temperature sensor.
2.For reliable performance, collapse, loose or distorted top part of the cover is prohibited during installation.
3.Liquid inleakage into the controller, crackle in the casing and unauthorized change of external terminal position are prohibited.
4.When the product is used in the circuit with maximum current of 5A, the cable with copper core at section 0. 5-1mm2 is required for connection; When the product is used in the circuit with maximum current of 10A, the cable with copper core at section 0.75-1.5 mm2 is required for connection;
5.The product should be kept in a clean, dry and corrosive gas-free warehouse with good ventilation and at relative humidity below 90%, environment temperature below 40.
Passed certifications :CQC UL VDE TUV SGS.



according to customers' requirements.
Jul-03-12
 
Detailed Product Description
Stable performance, high accuracy, small size, lightweight, high reliability, long lifespan, less interference to radio

Name:thermostat
model:KI-31

Technical parameters:
Electrical parameters: 1)CQC,VDE,UL,CUL AC250V 50~60Hz 5A/10A/15A (Resistance load)
2)UL AC125V 50Hz 15A (Resistance load)
2.Action temperature range: 45~160 (Optional); temperature accuracy:
3.Recovery and action temperature difference: 8~100 (Optional)
4.Connection method: Insert the terminal 250# (bending angle: 0~90¡ã optional); Insert the terminal 187# (bending angle: 0~90 optional; thickness: 0.5, 0.8mm optional)
5.Lifespan: 100,000 times
6.Electrical strength: No spark or breakdown for 1min at AC 50Hz 1800V
7.Contact resistance: 50m
8.Insulation resistance: 100m
Junction method: Constant-closed: the contact point disconnects when temperature rises; and contact point connects when temperature falls
Constant-opened: the contact point connects when temperature rises; and contact point disconnects when temperature falls.
10.Casing protective class: IP00
11.Grounding method: Connection is made between the metal casing of the temperature controller and the metal part of the grounding device.
12.Installation method: installed for KI031 series: general moving ring, mini round moving ring, flat moving ring general aluminum cover with mounting hole, extra length aluminum cover with mounting hole

Structure and application:
KI-31serial products are the temperature controllers taking bimetallic strip as the temperature-sensing unit. In case of normal operation the electrical appliance, the bimetallic strip is in a free state; the contact point is in a state of close/open. When the temperature reaches the action temperature, the bimetallic strip performs quick action generates caused by internal stress due to heating; open/close the contact point; disconnect/connect the circuit; thus, the temperature is in control. When the electrical appliance is cooled to the recovery temperature, the contact point automatically opens/closes to recover normal operation state.
Widely used in electrical heating appliances like water dispenser, water heater, sandwich bread baker, dishwasher, dryer, sterilizing cupboard, micro-wave oven, electric heating coffee pot, electric cooker, refrigeratory, air-conditioner, laminator, heater of auto seat.

Characteristics:
Stable performance, high accuracy, small size, lightweight, high reliability, long lifespan, less interference to radio

Precautions:
1.When adopting contact temperature sensing installation, the surface of the metal cover is required to be securely contacted with the installing surface of the controlled device. For ensuring the temperature sensing effect, it is required to coat thermal conductive grease or other similar thermal conductive medium on the surface of temperature sensor.
2.For reliable performance, collapse, loose or distorted top part of the cover is prohibited during installation.
3.Liquid inleakage into the controller, crackle in the casing and unauthorized change of external terminal position are prohibited.
4.When the product is used in the circuit with maximum current of 5A, the cable with copper core at section 0. 5-1mm2 is required for connection; When the product is used in the circuit with maximum current of 10A, the cable with copper core at section 0.75-1.5 mm2 is required for connection;
5.The product should be kept in a clean, dry and corrosive gas-free warehouse with good ventilation and at relative humidity below 90%, environment temperature below 40.
Passed certifications :CQC UL VDE SGS.



according to our custom.
Jul-17-12
 
Basic Info.
Model NO.: KI31
Control Type: Digital
Display Type: Blender
Material: Plastic/ Ceramic
Certification: CE/CQC/CB/UL/cUL/TUV
Usage: Temperauter Control
Type: Temperature Switch
Max Voltage: 250V
Max Current: 16A
Body Material: Bakelite or Ceramic
Temperature Characteristics: Normal Opened or Normal Colsed
Terminal Angle: Horizontal or Vertical
Terminal Type: 6.3mm or 4.8mm
Export Markets: Global

Additional Info.
Trademark: HX
Packing: Carton or According to Customers Requirements
Standard: customized
Origin: Dong Guan,Guang Dong ,China
HS Code: 9032100000
Production Capacity: 3000000 PCS Per Month

Product Description
Technical parameters:
Electrical parameters:
1)CQC, VDE, UL, cUL AC250V 50~60Hz 5A/10A/15A (Resistance load)
2)UL AC125V 50Hz 15A (Resistance load)
2. Action temperature range: -10~260Centigrade (Optional); Temperature accuracy: 10Centigrade
3. Recovery and action temperature difference: 8~100Centigrade (Optional)
4. Connection method: Insert the terminal 250# (bending angle: 0~90¡ã Optional); Insert the terminal 18(bending angle: 0~90¡ã Optional; Thickness: 0.5, 0.8mm optional)
5. Lifespan: ¡Ý 100, 000 times

6. Electrical strength: No spark or breakdown for 1min at AC 50Hz 1800V
7. Contact resistance: 50M
8. Insulation resistance: 100M
Junction method: Constant-closed: The contact point disconnects when temperature rises; And contact point connects when temperature falls;
Constant-opened: The contact point connects when temperature rises; And contact point disconnects when temperature falls.
10. Casing protective class: IP00
11. Grounding method: Connection is made between the metal casing of the temperature controller and the metal part of the grounding device.
12. Installation method: Installed for KI031 series: General moving ring, mini round moving ring, flat moving ring general aluminum cover with mounting hole, extra length aluminum cover with mounting hole

Office Equipment Snap-action Thermostat
Applications of KSD301 Thermostat
1. Water dispenser, Electric heater, Sandwich toasters, Dishwashers, Dryers, Disinfection cabinet, Microwave ovens, Electric coffee pot, Electric caldron, Refrigerator, Air conditioning gluing machine
2. Office equipment
3. The seat heaters.


1. 250V15A thermostat
2.Plastic body or ceramics body
3.Normal close or normal open
4. VDE TUV UL CE Certificate
Jul-17-12
 
Detailed brass screw bimetal thermostat description

fixation of the working temperaturing
reliable snap action
perdurable
less radio interference
Technical parameters:
Electrical parameters: 1)CQC,VDE,UL,CUL AC250V 50~60Hz 5A/10A/15A (Resistance load)
2)UL AC125V 50Hz 15A (Resistance load)
2.Action temperature range: 45~160 (Optional); temperature accuracy:
3.Recovery and action temperature difference: 8~100 (Optional)
4.Connection method: Insert the terminal 250# (bending angle: 0~90deg optional); Insert the terminal 187# (bending angle: 0~90deg optional; thickness: 0.5, 0.8mm optional)
5.Lifespan: over100,000 times
6.Electrical strength: No spark or breakdown for 1min at AC 50Hz 1800V
7.Contact resistance: less than 50m
8.Insulation resistance: less than100M
Junction method: Constant-closed: the contact point disconnects when temperature rises; and contact point connects when temperature falls;
Constant-opened: the contact point connects when temperature rises; and contact point disconnects when temperature falls.
10.Casing protective class: IP00
11.Grounding method: Connection is made between the metal casing of the temperature controller and the metal part of the grounding device.
12.Installation method: installed for KI031 series: general moving ring, mini round moving ring, flat moving ring general aluminum cover with mounting hole, extra length aluminum cover with mounting hole


Structure and application:
KI-32 serial products are the temperature controllers taking bimetallic strip as the temperature-sensing unit. In case of normal operation the electrical appliance, the bimetallic strip is in a free state; the contact point is in a state of close/open. When the temperature reaches the action temperature, the bimetallic strip performs quick action generates caused by internal stress due to heating; open/close the contact point; disconnect/connect the circuit; thus, the temperature is in control. When the electrical appliance is cooled to the recovery temperature, the contact point automatically opens/closes to recover normal operation state.
Widely used in electrical heating appliances like water dispenser, water heater, sandwich bread baker, dishwasher, dryer, sterilizing cupboard, micro-wave oven, electric heating coffee pot, electric cooker, refrigeratory, air-conditioner, laminator, heater of auto seat.


Characteristics:

Stable performance, high accuracy, small size, lightweight, high reliability, long lifespan, less interference to radio

Precautions:
1.When adopting contact temperature sensing installation, the surface of the metal cover is required to be securely contacted with the installing surface of the controlled device. For ensuring the temperature sensing effect, it is required to coat thermal conductive grease or other similar thermal conductive medium on the surface of temperature sensor.
2.For reliable performance, collapse, loose or distorted top part of the cover is prohibited during installation.
3.Liquid inleakage into the controller, crackle in the casing and unauthorized change of external terminal position are prohibited.
4.When the product is used in the circuit with maximum current of 5A, the cable with copper core at section 0. 5-1mm2 is required for connection; When the product is used in the circuit with maximum current of 10A, the cable with copper core at section 0.75-1.5 mm2 is required for connection.
5.The product should be kept in a clean, dry and corrosive gas-free warehouse with good ventilation and at relative humidity below 90%, environment temperature below 40.
956 Temperature Controllers Indicators Suppliers
Short on time? Let Temperature Controllers Indicators sellers contact you.
Jul-03-12
 
Thermostat
Detailed screw type bimetal thermostat description
1:auto rest
2:cremis shell
3.6.3*0.8 terminal
4:CQC UL VDE TUV SGS


Detailed brass screw bimetal thermostat description
fixation of the working temperaturing
reliable snap action
perdurable
less radio interference

Technical parameters:
Electrical parameters: 1)CQC,VDE,UL,CUL AC250V 50~60Hz 5A/10A/15A (Resistance load)
2)UL AC125V 50Hz 15A (Resistance load)
2.Action temperature range: 45~160 (Optional); temperature accuracy:
3.Recovery and action temperature difference: 8~100 (Optional)
4.Connection method: Insert the terminal 250 bending angle: 0~90deg optional); Insert the terminal 187(bending angle: 0~90deg optional; thickness: 0.5, 0.8mm optional)
5.Lifespan: over100,000 times
6.Electrical strength: No spark or breakdown for 1min at AC 50Hz 1800V
7.Contact resistance: less than 50m
8.Insulation resistance: less than100M
Junction method: Constant-closed: the contact point disconnects when temperature rises; and contact point connects when temperature falls
Constant-opened: the contact point connects when temperature rises; and contact point disconnects when temperature falls.
10.Casing protective class: IP00
11.Grounding method: Connection is made between the metal casing of the temperature controller and the metal part of the grounding device.
12.Installation method: installed for KI031 series: general moving ring, mini round moving ring, flat moving ring general aluminum cover with mounting hole, extra length aluminum cover with mounting hole


Structure and application:
KI-32 serial products are the temperature controllers taking bimetallic strip as the temperature-sensing unit. In case of normal operation the electrical appliance, the bimetallic strip is in a free state; the contact point is in a state of close/open. When the temperature reaches the action temperature, the bimetallic strip performs quick action generates caused by internal stress due to heating; open/close the contact point; disconnect/connect the circuit; thus, the temperature is in control. When the electrical appliance is cooled to the recovery temperature, the contact point automatically opens/closes to recover normal operation state.
Widely used in electrical heating appliances like water dispenser, water heater, sandwich bread baker, dishwasher, dryer, sterilizing cupboard, micro-wave oven, electric heating coffee pot, electric cooker, refrigeratory, air-conditioner, laminator, heater of auto seat.


Characteristics:
Stable performance, high accuracy, small size, lightweight, high reliability, long lifespan, less interference to radio

Precautions:
1.When adopting contact temperature sensing installation, the surface of the metal cover is required to be securely contacted with the installing surface of the controlled device. For ensuring the temperature sensing effect, it is required to coat thermal conductive grease or other similar thermal conductive medium on the surface of temperature sensor.
2.For reliable performance, collapse, loose or distorted top part of the cover is prohibited during installation.
3.Liquid inleakage into the controller, crackle in the casing and unauthorized change of external terminal position are prohibited.
4.When the product is used in the circuit with maximum current of 5A, the cable with copper core at section 0. 5-1mm2 is required for connection; When the product is used in the circuit with maximum current of 10A, the cable with copper core at section 0.75-1.5 mm2 is required for connection;
5.The product should be kept in a clean, dry and corrosive gas-free warehouse with good ventilation and at relative humidity below 90%, environment temperature below 40.
Passed certifications :CQC UL VDE TUV SGS.



according to customers' requirements.
Jun-01-12
 
Used on refregirator, icecmaker machine, drier, air-conditioner etc.
Aug-18-09
 
Thermostat control.
Apr-17-12
 
The Apollo touch screen room thermostat is mainly applied the Heat pump, Gas Heating, Electric Heating, and so on systems.

Features:
24VAC or Battery Powered (2 x AAA)
Large Backlit LCD Touch Screen
Security Logic inc Key lock & Limit Control
7 day, 5+2 Day or Manual Operation
Programmable Fan Logic
Heat cool & Heat Pump Logic
Single & Multistage Control
Remote Sensor Inputs
Outside Sensor Inputs
Designed and built by Smart Temp Australia
Comprehensive 3 year Warranty RTB

Specifications:
Input Voltage (Hardwired) 20-30 VAC 50/60 Hz
Relay Rating 24 VAC @ 1 Amp Max Per Relay
Battery Power (2) AAA 1.5 V
Operating Temperature 0° C to 55° C
Operating Relative Humidity 0-95% (non-condensing)
Storage Temperature 0° C to 65° C
Size: 125" W x 85" H x 25" D (mm)
LCD Display Size 57 W x 99 H (mm)
Back Light White LED
Short-Cycle Delay Off or 4 minutes
Displayed Temperature Resolution 0.1° C
Set Point Range
Heating 5° C - 49° C
Cooling 6° C - 50° C
Heating and Cooling Limits Fully adjustable
Onboard Sensor NTC type 3 100K
Remote NTC type 3 10K
Warranty 3 years (RTB).
Apr-13-12
 
Thermocouples are manufactured in many different configurations for multitude of applications. Diameters, lengths, sheath material, lead lengths and sensor material are just a few of the variables that go into determining the style of thermocouple when manufactured. The main determining factors of what type thermocouple needs to be used in a application is temperature, environment, response time and accuracy. The junction of the thermocouple can be grounded, ungrounded or exposed. The thermocouple junction may be of many different styles, from tube type to a washer configuration. The lead length may vary depending on the distance of the temperature controller from the thermocouple sensor. The metal that the sensor is constructed of determines the type of thermocouple manufactured.Applications:

Plastic injection molding machinery Food processing equipment Engine and turbine exhaust gas Semiconductor processing Heat treating and metals processing Medical equipment Aerospace industries Packaging equipment Test stands Features
Thermocouple Wires: Cromel-Alumel, Iron- Constant, Copper-Constant, imported Bright & Oxidized finish, SWG 10 to 36. PT/PTRH 10%, 13% . Thermocouple Extension & Compensating Cables: Fiber glass covered, PVC / PVC. Asbestos / Asbestosis, Teflon/Teflon, Insulated, Teflon/Fg/SS Braided single pair, multi pair, Type K, J, T, R, and PT-100 RTD Cables 2 core, 3 core, 4 core , 6 core, Also Teflon /silicon rubber Teflon/shielded/Teflon etc qualities. Thermocouple M.I. Cables: SS 316, 310 & Inconel 600 quality type K, J, Simplex 1mm,1.5mm, Simplex & Duplex 3mm,6mm, 8mm, also PT-100 RTD Thermocouple M I Cables SS 316 quality. 3mm, 5mm, 6mm 4 core Thermocouple Assemblies: Straight, L Type , Rotating type, Inmelt Bolt type, Pencil type, Washer, Holder with Spring. Rotating Type, Adjustable Types etc. Made out of SS tube 4.8mm, 6mm,supplied with Spring & Brass bayonets Single Slot & Double Slot , 10mm id, 12mm id, 14mm id, etc. Thermocouple Brass Parts: ADAPTORS 1/8 BSP, 1/4 BSP, 1/2 BSP, 3/8 BSP Single Pin, Double pin Bayonets.


Carton box and wooden box.
Mar-27-12
 
Various types of thermocouple
Can be widely supplied as
Customer's requirment--good
Erosion-resistant, corrosion-resistant

1) Thermocouples specified for food, health, medicine, and light industries
2) Inert-gas-filled thermocouples and thermocouples for temperature measurement on ships
3) Thermocouples with stainless steel terminal box

Features:
1) Complete stainless steel structure
2) With npt threaded connection and flange
3) Assorts of lengths and diameters
4) Thermo-wells and assembled integrated transmitters are supplied.



Plastic bags and carton box.
Mar-20-12
 
PH-099, designed for simultaneous pH and ORP measurements.
It also reads temperature, which is continuously displayed on the dual level LCD.
It is a waterproof pH, ORP and temperature meter.
All pH readings are automatically temperature compensated(ATC).
Measurements are highly accurate with a unique stability indicator right on the LCD.

The pH electrode, supplied with the meter, is interchangeable and can be easily replaced by the user.
Range : mV 0~1999mV
pH : 0.00 to 14.00 pH
Temperature : 0 to 55
Resolution : mV 1 mV
pH : 0.01 pH
Temperature : 0.1
Accuracy : mV 5mV
pH : 0.1 pH
Temperature : 1
Temperature Compensation : 0 to 50
Electrode : replaceable pH electrode (included);fixed ORP sensor
Power Supply : 4 x 1.5V(AG13)
Environment : 0 to 50
Dimensions : 170 x 40 x 23 mm
Weight : 100 g.
Mar-19-12
 
Thermocouples are manufactured in many different configurations for multitude of applications. Diameters, lengths, sheath material, lead lengths and sensor material are just a few of the variables that go into determining the style of thermocouple when manufactured. The main determining factors of what type thermocouple needs to be used in a application is temperature, environment, response time and accuracy. The junction of the thermocouple can be grounded, ungrounded or exposed. The thermocouple junction may be of many different styles, from tube type to a washer configuration. The lead length may vary depending on the distance of the temperature controller from the thermocouple sensor. The metal that the sensor is constructed of determines the type of thermocouple manufactured.

Applications:
Plastic injection molding machinery
Food processing equipment
Engine and turbine exhaust gas
Semiconductor processing
Heat treating and metals processing
Medical equipment
Aerospace industries
Packaging equipment
Test stands

Features:
Thermocouple Wires: Cromel-Alumel, Iron- Constant, Copper-Constant, imported Bright & Oxidized finish, SWG 10 to 36. PT/PTRH 10%, 13% .
Thermocouple Extension & Compensating Cables: Fiber glass covered, PVC / PVC. Asbestos / Asbestosis, Teflon/Teflon, Insulated, Teflon/Fg/SS Braided single pair, multi pair, Type K, J, T, R, and PT-100 RTD Cables 2 core, 3 core, 4 core , 6 core, Also Teflon /silicon rubber Teflon/shielded/Teflon etc qualities.
Thermocouple M.I. Cables: SS 316, 310 & Inconel 600 quality type K, J, Simplex 1mm,1.5mm, Simplex & Duplex 3mm,6mm, 8mm, also PT-100 RTD Thermocouple M I Cables SS 316 quality. 3mm, 5mm, 6mm 4 core
Thermocouple Assemblies: Straight, L Type , Rotating type, Inmelt Bolt type, Pencil type, Washer, Holder with Spring. Rotating Type, Adjustable Types etc. Made out of SS tube 4.8mm, 6mm,supplied with Spring & Brass bayonets Single Slot & Double Slot , 10mm id, 12mm id, 14mm id, etc.
Thermocouple Brass Parts: ADAPTORS 1/8 BSP, 1/4 BSP, 1/2 BSP, 3/8 BSP Single Pin, Double pin Bayonets.


Wooden box/carton.
Feb-23-12
 
1 RFT8100 wireless temperature and humidity detection system

is composed by wireless temperature detection probes, humidity detection probes and display terminals. Adopting the advanced wireless temperature detection technology, RFT8100 transmits and displays the real time value detected from the local detection probes for the purpose of inspecting temperature and humidity on-site routinely. The alarm relay sends out signal when the temperature and humidity data exceeds or lowers the setting alarm value, and the alarm points can be found quickly by checking the alarm information. RFT8100 also provides curve diagram for checking temperature and humidity variation in short period for equipments management purpose. RFT8100 can achieve the remote monitoring function by transmitting the measured data to DCS monitor centre or equipments management centre thru RS-485 port or Ethernet port.


2 EMC and safety standard

IEC61000-4-2 (GB/T17626.2)
IEC61000-4-8 (GB/T17626.8)
IEC61000-4-4 (GB/T17626.4)
IEC61010-1 (GB/T4793.1).



Exterior Size:91*91*72mm
0.5KGS.
Dec-06-11
 
1. Auto fan
Adjust fan speed automatically according to the temperature
Differential between set value and room temperature
2. Sleeping mode
Adjust the setting temperature automatically according to the
Thermal environmental conditions.
3. Shortcut menu
Enter into the pre-setting temperature directly
4. Key-lock function
To avoid erroneous operations
5. Timer off function
To deactivate the thermostat at your pre-setting time
6. Timer on function
To activate the thermostat at your pre-setting time
7. On/off key
Zero power consumption after switching off
8. Back light(Optional)
Display with backlight, stay on for 15seconds
9. LCD display
Inclined larger size LCD display for better read out
10. Sensor calibration
To ensure accurate temperature measurement
11. Setting min. /max. Allowed temperature
12. Valve indicator
13. Alternate from Cooling/heating by manual
14.18months Guarantee, ISO9001, CE, FCC.
Dec-06-11
 
1.Large LCD screen with blue backlight
2.Setting Temperature Range: 16-35º C,Room temperature:0-50º C
3.Wiring box: 86mm*86mm
4.High grade electronic accessory
5.TX-1008 remote controller is optional(Price is differ)
6.Temperature precision:1º C
7.Locked by remote controller is optional
8.Electric parameter: AC220V±10% 50/60Hz.
Dec-06-11
 
1.Temperature setpoint:16º C-35º C.room temperature: 0º C-50º C
2.LCD light screen shows the running condition of valve
3.Sleeping function
4.Manual alternate of cool or heat
5.Automatically adjust the wind speed
6.Set output delay time about 0-10 minutes
7.Advanced microcomputer control wafer
8.room temperature control precision 1º C.
9.Shell Material: White ABS flameproof plastic
10.Electric parameter: AC110/220V±10% 50/60Hz
11.Two-line, three-line motorized valve
12.Two-pipe, Four-pipe cooling and heating system.
Oct-17-11
 
MS182 is a smart in-head transmitter module with HART® -protocol. It has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection, and converts various input signals into a standard 4 to 20 mA analog output signal after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short.
Primary Technical Characteristics
Programmable Use PC or the hand operator
Measuring range Set via PC or by the hand operator
Input type RTD, TC, R or Millivolt signal
Convert accuracy 0.1£¥FS
Cold junction accuracy ¡À1(TC)
Output 4¡«20mA/20¡«4mA Electrical isolation output
HART ¨CProtocol output
Max-load £¨V -13V£©/0.025A£¨Current output £©
Limit current 25mA
Response time 1s
Isolated voltage 1500V AC (input/output)
Alarm signal Programmable
Underranging linear drop to 3.8 mA
Overranging linear rise to 20.5 mA
Sensor break or short-circuit:
3.6mA or ¡Ý21.0mA
Power supply 13¡«30V DC
Temperature drift 0.01£¥ FS/1
Long-term stability 0.1 per year or 0.05 £¥per year
Ambient -40¡«+85.
Oct-17-11
 
MS181 is an intelligent temperature transmitter module which can be programmed through a PC with Configuration Kit. It has measurement input for resistance thermometers (RTD) ,thermocouples, resistances or millivolt signals in 2-,3- or 4-wire connection, and converts various input signals into a 4~ 20mA analog output signal after linear processing. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short.
Primary Technical Characteristics
Programmable Use the MS181 programming tool
Measuring range Set via PC
PC Interface USB/RS232
Input type RTD, TC, R or Millivolt signal
Convert accuracy ¡Ü0.1£¥FS
Cold junction accuracy ¡À1(TC)
Output 4¡«20mA/20¡«4mA Electrical isolation output
Max-load £¨V -8V£©/0.025A£¨Current output £©
Limit current ¡Ü25mA
Response time 1s
Isolated voltage 1500V AC (input/output)
Alarm signal Programmable
Underranging linear drop to 3.8 mA
Overranging linear rise to 20.5 mA
Sensor break or short-circuit:
¡Ü3.6mA or¡Ý21.0mA
Power supply 8¡«30V DC
Temperature drift 0.01£¥ FS / 1
Long-term stability ¡Ü0.1 per year or 0.05£¥ per year
Ambient -40¡«+85
Oct-17-11
 
MS183 , a smart 2-wire in-head and dual-input transmitter module with HART® -protocol, has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection and converts various input signals into a standard 4 to 20 mA analog(high selector, average value or D-value) output signal or 2-way digtal output signals with HART® -protocol after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation also is provided between the input and output. A special signal can be set in advance while the sensor burnout or short.
Primary Technical Characteristics
Programmable Use PC or the hand operator
Measuring range Set via PC or by the hand operator
Input type Dual-input ( RTD, TC, R or Millivolt signal)
Convert accuracy ¡Ü0.1£¥FS
Cold junction accuracy ¡À1¡æ(TC)
Output 4¡«20mA/20¡«4mA Electrical isolation output
HART ¨CProtocol output (2-way)
Max-load £¨V -16V£©/0.025A£¨Current output £©
Limit current ¡Ü25mA
Response time 1s
Isolated voltage 1500VAC (input/output)
Alarm signal Programmable
Underranging linear drop to 3.8 mA
Overranging linear rise to 20.5 mA
Sensor break or short-circuit:
¡Ü3.6mA or ¡Ý21.0mA
Automatic switching while sensor damaged
Power supply 16¡«30V DC
Temperature drift 0.01£¥ FS/1¡æ
Long-term stability ¡Ü0.1¡æ per year or 0.05 £¥per year.