SBM cone crusher
7*100, 1*200 drawer. 3*3 seperation in the drawer. Powder coating. 565*600*1000hmm, weight: 70kg, volume: 0.4
Features heel bracket adjustable for any foot size Leg band with pads for comfort Adjustable springs&nylon adapter straps Upper and below struct tube for enstension&rubber feet to prevent slipping Used in decoration or construction, also can be used in entertainmentperformance Safety and efficiency for are improved Stilts-1523 1)Height:380mm-585mm, Net weight:5.80kg.2)Material:Aluminium or Magnesium Stilts-1830 1)Height:460mm-765mm, Net weight:6.20kg.2)Material:Aluminium or Magnesium Stilts-2440 1)Height:610mm-1020mm,Net weight:7.20kg.2)Material:Aluminium or Magnesium
Wrench
Item no.: arx-831l 7 inch air angle grinder (safety lever type) Free speed....................7, 000rpm Disc size........................7 inch Standard spindle size.....5/8" x 11unf Option spindle size.........M14 x 20pitch Air inlet..........................3/8"pt Air hose.........................3/8f+ (10mm)
Tool kit
DIN933 Bulk in carton
Electric drills, angle grinders, screw drivers, drill bit, sharpenersrotary tools circular saws mini carving, drilling kit cut-off machines, marble cutterother tools.
EMI receiver system for EMI (Electromagnetic Interference) radiation conduction or conducted emissions testing. The EMI-9KB EMI receiver is made of full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem. The test results are according to the international format test report. The EMI Test System EMI-9KB fully meets CISPR15:2018, CISPR16-1, GB17743, FCC, EN55015 and EN55022.System Configurations: EMI-9KC Test System includes: EMI-9KC EMI Receiver built-in Attenuator (9K-1GHz), LISN Artificial Network Power, CDNE-M316 Coupling/Decoupling Network for Emission, Isolation Transformers, Attenuator and cables. EMI-9KB Test System includes: EMI-9KB EMI Receiver (9K-300MHz), LISN Artificial Network Power, CDNE-M316 Coupling/Decoupling Network for Emission, Isolation Transformers, Attenuator and cables. EMI-9KA Test System includes: EMI-9KA EMI Receiver (9K-30MHz), LISN Artificial Network Power, Isolation Transformers, Attenuator and cables.Option instruments to work with the EMI-9KC, EMI-9KB and EMI-9KA EMI receivers: LISUN LSP-500VARC/LSP-1KVARC Pure Sine Wave AC Power Source for EUT LISUN SDR-2000B Magnetic Shielding Cabinet for the EMI Receiver System LISUN VVLA-30M Three Loop Antenna to test 9k-30MHz radiation LISUN AB-CLP Absorbing Clamp to test the home applications & motor tools LISUN VOL-CP RF Current Probe to the conducted disturbance voltageSpecification: Detection frequency range: 9kHz~1GHz (EMI-9KC), 9kHz~300MHz (EMI-9KB), 9kHz~30MHz (EMI-9KA) Frequency stability: 1 10^-6 Frequency resolution: (9kHz~150kHz) 30Hz; (150kHz~30MHz) 1kHz Test Tolerance: ±2 dB Measure and Detection method: PK, QP and AV Measure range: 20dB V~140dB V Frequency scanning step frequency: 20Hz~2MHz Sweep bandwidth: 200Hz; 9kHz; 120kHz Connect PC via USB cable and software can run on Win7, Win8, Win10, Win11
According to IEC60695-2-2, IEC60695-11-5 and GB/T-5169.5, ZY-3/ZY-3S needle flame test equipment is applied in the production and quality control department of lighting products, hyperpiesia electrical apparatus, domestic appliance, machine electric appliance, electrical machine, power tool, electronic instrument, electrician instrument and technical equipment. Also, the apparatus is suitable for the industry of insulation material, engineering plastics and solid combustible material.Specifications: Angle of burner: 45�° (when in test) / 0�° (when adjust the flame height) Needle flame burning time: 0~999.9s ±0.1s (adjustable, 30s in general) After-flame time: 0~999.9s ±0.1s, auto record and pause manually Height of flame: 12mm±1mm (gauge is included) Gas: 95% butane Test range of temperature: 0~1000 The temperature rises from 100 ±2 to 700 ±3 within 23.5 seconds ±1s Thermocouple: 0.5mm K type Applied with touch screen and remote controlTo save the delivery cost for the oversea market, LISUN designed a compact version needle flame test equipment weighing less than 50kg. (Customer need to prepare additional ventilation system for ZY-3S) What is a needle flame test? The full name of IEC 60695-2-2 is Fire hazard testing Part 2: Test methods Section 2 Needle-flame test. It was prepared by IEC technical committee 89: Fire hazard testing. The following is the related introduction of IEC 60695-2-2 Scope.This section of IEC 60695-2-2 specifies a needle-flame test to simulate effect of small flames which may result from fault conditions within equipment, in order to assess by a simulation technique the fire hazard.It is applicable to electrotechnical equipment, its sub-assemblies and components and to solid electrical insulating material or other combustible materials.What is flame retardant test methods? In the case of horizontal needle flame test HB classification, the sample size is required to be 125mm in length, 13mm in width, and no more than 13mm in thickness. The sample is placed horizontally, the sample clamp is clamped to one end of the sample, and the ignition device is at a 45 degree angle to keep the flame position unchanged. Apply 30±1S to the other end of the sample holder, and place a metal mesh and a freely movable fixed frame horizontally under the sample holder,
Product Description The LS9955/LS9956 Automatic Safety Test System (electrical safety analyzer) combined the following function in one set: Withstand Voltage Test (AC/DC), Insulation Resistance Test (IR), Leakage Current Test (LLC), Grounding Resistance Test (GR) and Power Test. The LS9955/LS9956 Automatic Safety Test System is according to GB4706.1, IEC/EN60335-1, UL60335, GB7000, IEC60598, GB4943, IEC60950 and GB9706.1. It is used for luminaries, home application and motor tools safety test in production line or R&D Lab. Specification: Remote control device and can control by software (Optional) Display all setting parameters and testing results in the same big LCD menu PASS/FAIL limit values can be set. It has alarm sound and indicator light Test mode programmable; 50 groups setting available, 8 test steps per group Quick discharge. Support 50Hz and 60Hz frequency; Electric safety wall detecting feature �¢?�¢ The LS9955 can do test for Withstand Voltage (AC/DC), Insulation Resistance (IR), Leakage Current (LLC) and Ground Resistance (GR) The LS9956 can test for Withstand Voltage (AC/DC), Insulation Resistance (IR), Leakage Current (LLC), Ground Resistance (GR) and Power
Product Description ESD simulator guns (Electrostatic Discharge Generator/Electrostatic Gun/ESD Guns) is in full compliance with IEC 61000-4-2, EN61000-4-2, ISO10605, GB/T17626.2, GB/T17215.301 and GB/T17215.322. What is a ESD test? The static electricity generated by the human body to the object or between two objects may cause the electrical and electronic equipment circuits to malfunction or even be damaged. The ESD generator is designed for the withstanding ESD performance measurement for the assessment of electrical and electronic equipment. ESD61000-2/ESD61000-2A has a LCD touch screen in both English and Chinese. What is an esd simulator gun used for? Electrostatic discharge simulator is highest electrostatic voltage can be up to 30 kv, which is enough to cover the most severe standard grade of electrostatic voltage requirement (the voltage requirements of the grade 4 air discharge electrostatic is 15 KV). The ESD test gun can be used for the most of electrical and electronic equipment for electrostatic discharge test, and also can ensure comparability and reproducibility of test. Specifications: Product Model ESD61000-2 ESD61000-2A Output Voltage 0.1~20kV ±5% 0.1~30kV ±5% Polarity Positive/Negative Positive/Negative Energy Storage Capacitance 150pF ±10% (Replaceable)
Product Description The Portable CCD LED Colorimeter Spectroradiometer has the following versions which can measure different parameters: LISUN Model Function Wave Range LMS-6000 illuminance (lux), E(Fc), Ee(W/m2), Tc (K), Duv Correlated Color Temperature (CCT), Chromaticity Coordinates, CRI, Purity, Peak Wavelength, Dominant Wavelength, Half Bandwidth, Center Wavelength, Centroid Wavelength, Total Color Difference, Brightness Difference, Red-Green Degree, Yellow-Blue Degree, CCT Difference, SDCM Diagram, Spectrum Diagram 380-780nm LMS-6000B LMS-6000 Parameters+Blue Light Hazard Weighted Irradiance according to GB/T20145, CIE S009/E:2002 350-800nm LMS-6000BF LMS-6000 Parameters+Flicker test, Blue Light Hazard Weighted Irradiance according to GB/T20145, CIE S009/E:2002 350-800nm LMS-6000F LMS-6000 Parameters+Flicker test 380-780nm LMS-6000L cd/m2, fL, Tc (K), Duv Correlated Color Temperature (CCT), Chromaticity Coordinates, CRI, Purity, Peak Wavelength, Dominant Wavelength, Half Bandwidth, Center Wavelength, Centroid Wavelength, Total Color Difference, Brightness Difference, Red-Green Degree, Yellow-Blue Degree, CCT Difference, SDCM Diagram, Spectrum Diagram 380-780nm LMS-6000P LMS-6000 Parameters+PAR, PPFD, YPFD, Blue-purple irradiance Eb, Yellow-green irradiance Ey, Red-orange irradiance Er, Ratio of red and blue radiation Erb_Ratio 380-800nm LMS-6000S LMS-6000 Parameters+PAR, PPFD, YPFD, Blue-purple irradiance Eb, Yellow-green irradiance Ey, Red-orange irradiance Er, Ratio of red and blue radiation Erb_Ratio, Rf and Rg according to TM-30 350-950nm LMS-6000UV UV-A, UV-B, UV-C and UV total Radiant Irradiance, UV hazard irradiance, UV spectrum, Dominant Wavelength, Peak signal, Start wavelength, End wavelength. Please click here to see the LMS-6000UV Test Report. 200-400nm LMS-6000SF LMS-6000 parameters+Flicker+Plant Lighting parameters+TM-30 350-950nm LMS-6000I Input and Output Control via RS485 380-780nm LMS-6000C LMS-6000 parameter without PC software 380-780nm Standards: Fully meet CIE 177, CIE-13.3 , Optical-Engineering-49-3-033602, and IEEE. The Chroma Meter Specifications: Spectral resolution: ±0.2nm, Reproducibility: ±0.5nm Accuracy of chromaticity coordinate ( x, y): ±0.005 Illuminance range: 5~200,000lx LCD screen: 5inch high definition IPS capacitive touch screen and resolution is up to 480*854 With 4000mAh rechargeable Li-ion battery which can continuously work for 20 hours Dimensions: 135mm*80mm*23mm Connect to PC via USB cable. English version software can run on Win7, Win8 or Win10
full set of fume hood test kit according to ASHRAE 110 &EN14175. High-sensitivity Trace Gas Leak Detector-Q200 Face Velocity Test Kit SF6 Ejector Kit Small Smoke Generator Kit Large-Volume Smoke Generator Kit Mannequin with stand Software: Compatible with ASHRAE 110-2016 Inner Measurement Plane Test Kit Outer Measurement Plane Test Kit Programmable Rectangular Plate Sample Pump
BOQU Industrial Online Conductivity TDS Meter is equipped with a microprocessor and complete English menu. It has display and menu operation pattern; it is characterized by its intelligent operation, multi-function and high measuring performance and its strong environmental adaptability. It can be widely used for continuous monitoring of the conductivities of solutions used in the following fields: thermal power plant, chemical fertilizer, chemical industry, metallurgy, environmental protection, pharmacy manufacturing, biochemistry, foodstuff and running water. Best 4 tank tds or ph EC monitoring tds meter 1)Instrument for industrial Conductivity,resistivity,salinity,TDSand temperature measurement, such as Waste water, drinking water environmental monitoring, fermentation, food production process etc. 2)Instrument for panel mounted,wall mounted,pipe mounted. 3)Instrument provide 2 ways of 4-20mA ,max load 500�©. 4)Instrument provide 3 ways of relays ,max 5A/250VAC or 5A/30VDC. 5)Instruments provide RS485 Modbus RTU communication.
LSG-6000 Moving Detector Goniophotometer Mirror Type C (updated version for LSG-5000/LSG-3000) is for LED measurement and completely meets LM-79-19 Clause 9.3.1 requirement. For candela intensity distribution, EEI, color temperature distribution and IES, LDT files measurement.
The movable bend of high pressure is an oil-field to fix the in common use tool of the well operation link pipe line, wash. Various models of AQE swivel joints and their repair kits are available, suitable for normal or low temperature, or H2S environments, with sizes ranging from V to 4* and rated WP ranging from 2000psi-20000psi (14MPa-140MPa). JEFA products are available in the models of style 20, style 30, style 40, style 50, style 60, style 70, style 80, style 10, and style 100. We use thread connection and union connection.
The fixture manufacturing can be carried out according to customer drawings The fixture can be designed and manufactured according to customer requirements.
Material: Copper Used For: 1/4 In And 3/8 In Standard Grounding Kit used for 1/4 in and 3/8 in Standard Grounding Kit used for 1/4 in and 3/8 in This type of grounding kit can be used for 1/4 in and 3/8 in corrugated & braided coaxial cable. It was designed according to Commscope (Andrew) GK-242948. Features of this product are installed by the cable ties. It allows it can be used for at least two types of coaxial cable. Standard Grounding Kit Compact structure Faster and easy installation No loose parts
LSG-1800BCCD Goniospectroradiometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800BCCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on. Measurement: Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution, Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR, CCT, CRI, Color Temperature Distribution, Spectrum, (x, y)/(u, v) and etc. Specification: LSG-1800BCCD Goniospectroradiometer=LSG-1800B Goniophotometer System + LPCE-2 Integrating sphere Spectroradiometer System The Europe classical goniophotometer which is fully meet EN13032-1 clause 6.1.1.3 goniophotometer type 1. â?¢ The goniophotometer can do the B-β test with two pillars and C-γ test with single pillar & multi-function jigs â?¢ The accuracy of angle: 0.1° (LSG-1800XCCD/LSG-1800BCCD) and 0.2° (LSG-1700BCCD) â?¢ Work with High Accuracy and quick CCD Spectraidomeeter to measure spatial color parameters. â?¢ Accuracy of chromaticity coordinate: ±0.0005 (under standard A lamp) â?¢ Spectral Range Wavelength: 380nm ~780nm; Accuracy of wavelength: ±0.5nm â?¢ Accuracy of photo detector: CIE Class A (Class L is for option) â?¢ Connect to PC via USB, English version software can be run in Win7, Win8 or Win10 â?¢ The test result can be exported as CIE, IES, LDT and other format files. This kind of format files can be transferred by other illumination and luminaire design software such as DiaLux Max Size for the Testing Lamp (mm) The Max Size for the Testing Lamp Max Weight Non-Flood Lamp Diameter*Depth Flood Lamp (L*M) LSG-1800XCCD Φ 2500*550mm 700*600mm 60Kg LSG-1800BCCD Φ 1600*550mm 700*600mm 50Kg LSG-1700BCCD Φ 1600*580mm 700*600mm 30Kg