Temperature.
PTFE, teflon, thermocouple, thermal resistance.
Heating coil unit.Business development
Thermocouple, temperature sensor, temperature controller.
Temperature instruments.
Hot runner system and related products, temperature controller box, time controller box.
Mold temperature control machine is widely used in various industries such as plastic molding, light guide plate die casting, rubber tires, rollers, chemical reaction kettle, bonding, banburying, etc.The heating power is from 6KW to 90KW, and the temperature control range is 25°C to 280 C. Safety protection system including reverse phase, phase-lack,, protection of power supply, water lack protection, abnormal temperature control protection(detect whether the pipeline is blocked),pumping overload protection, overheating protection, locking the upper limit of temperature control, abnormal temperature sensing element protection, temperature sensing element shutoff protection, emergency stop device ,abnormal alarm buzzer.
Type: k/j/e/n/t Temperature range: 0-350¡æ Probe length: 50~1000mm Probe diameter: 3.0~20.0mm Installation: thread or flange 1 piece per box and 15 boxes per carton
mps and other lighting, improving sensor accuracy. Thinner lead wire is less stiff and more pliable for application on the skin and reduces the interference of ambient air on the temperature reading (the stem effect). The sensor is embedded in the centre of the foam disk to reduce the likelihood of sensor separation from the foam. This feature also decreases the risk of irritation in patients with, sensitive skin. Moq 1000
oam. Pvc applicator and strain relief makes insertion easy while protecting the lead wire from kinks and thinner lead wire is more pliable and provides greater accuracy. Available in pediatric and adult configurations. Box Moq 1000
Description The esophageal/rectal probes provide for accurate measurement of body temperature. The probe can be placed in the esophagus, rectum, nasopharynx, or axilla. The probes are available in both 9fr and 12fr meeting the needs of adult and pediatric patients. Our probes are compatible with all series ysi400 patients monitoring equipment. In addition, our esophageal/real probes can be customized being. A tip-to-end pvc sleeve protects the lead wire from strain, breaks, kinks, and interference from ambient air, enhancing product quality and temperature accuracy. mia equipment providing an accurate, low cost alternative. Box Moq 1000
1.It is made of specular stainless steel(304 in China) and semicirular arcs at corners ensures easy cleaning. 2.Microprocessor temperature controller makes temperature stability. 3.Door temperature controller prevents dewfall on glass door of incubator effectively. 4.Microorganism filter at inlet provides 100% filtrated gases. 5.Main parts are all imported,equipped with CO2 pressure releasing valve.(Special for CO2 incubator) Model HHCP-T(80L)with UV light Electrical Requirement 220V 50HZ Input Power (W) 450 Heating Method Air-jacket Temperature Range(Degree) RT+5~50 Temperature Control (Degree) 0.1 Temperature Stability(Degree) 0.3 CO2 Range 0~20% CO2 Recovery Calibration*1.2min Humidifying Method Natural Evaporization Ambient Temperature(Degree) +5~35 Cubage(L) 80L W*D*H Interior Dimension(mm) 500*400*400 W*D*H Overall Dimension(mm) 570*570*820 Shelves per Chamber 2PCS . Packing Style: Standard Export Packing Style W*D*H Packing Dimension(mm): 710*710*920 Gross Weight: 67KG Net Weight: 51.5KG.
Type: k, e, j, n, s , pt-100 Temperature range: -200 c to 1300 c Size can be customize
Thermocople 1) resist high & low temperature, corrosion , chemicals 2) synthetic fertilizer widely used in large towers, storage tanks, and other devices 3) good appearance and properties 4) good flexibility 5) supper electrical property 6) anti -adhesive 7) all sizes are avilable All size available on customers' requests
Thermocople 1) resist high & low temperature, corrosion , chemicals 2) synthetic fertilizer widely used in large towers, storage tanks, and other devices 3) good appearance and properties 4) good flexibility 5) supper electrical property 6) anti -adhesive 7) all sizes are avilable All size available on customers' requests
Thermostat High control accuracy at the maximum of 0.1; Double pid control functions, capable of controlling heating and cooling; General input, capable of selecting 56 kinds of different input information; A variety of output modes to greatly meet many requirements for load control; Capable of selecting pv (measurement value) or sv (set value) 4-20ma transmission output functions; Capable of selecting external remote control set value functions, which can be used for multiple unit synchronous setup; Output percentage restriction function and manual/automatic non-disturbance switching; Automatic diagnosis function, capable of displaying information on any failures; Capable of selecting this rs485 communication function Automatic diagnosis function, capable of displaying information on any failures; Capable of selecting this rs485 communication function
High control accuracy at the maximum of ía0.1íµ; Double pid control functions, capable of controlling heating and cooling; General input, capable of selecting 56 kinds of different input information; A variety of output modes to greatly meet many requirements for load control; Capable of selecting pv (measurement value) or sv (set value) 4-20ma transmission output functions; Capable of selecting external remote control set value functions, which can be used for multiple unit synchronous setup; Output percentage restriction function and manual/automatic non-disturbance switching; Automatic diagnosis function, capable of displaying information on any failures; Capable of selecting this rs485 communication function
Quality: long using life gurantee Placed postion: 1) Horizontal 2) Upright
Voltage monitor Under/over voltage protection Voltage unbalance protection Phase loss protection Phase reverse protection
Temperature controller Features: High accuracy, reasonable price and easy operation Self-diagnosis function Fuzzy pid autotuning function is supplied as standard 1 ramp 1 dwell, and dwell time Soft start Input/output, isolated Fully configurable for t/c, rtd or linear Adjustable pv offset Heat/cool bimode output 1 alarm standard, optional 3nd alarm with 17 alarm models Pv, sv value, re-transmitter. Remote setpoint Switching power supply, ac85-265v 50/60hz or dc24v Preventive water, dust. (optional) P900 series process controllers 3 control patterns: 1 8-segment, 2 8-segment and 1 16-segment, can be chosen freely. Rs485 communication function, emi/esd protective function Measuring accuracy: ía0.5Ñfs (ía0.2Ñfs available) No need for backup battery, can memory information above 10 years Main technical index: External dimension and holing size (unit: mm