Please click here to check who's online and chat with them.

Find Verified Telecommunication Infrastructure Equipments Suppliers, Manufacturers and Wholesalers

Top Supplier Cities : Shenzhen   Guangzhou   Shanghai  
Jun-16-21
 
Mold of Communication Box
Sep-13-19
 
SPECIFICATION:
Mobile Standard system: GSM/GRPS
Support Frequency: 900/1800MHz;850/1900MHz
Standby time:7*24 hours
Weight:69g
Size:73*53*19mm

Function:
Fall Detect and auto alarm
SOS button and 2-way call communication
GPS/LBS location
Unit status by SMS
Monitored Battery
Power-on Prompt by SMS
Remote Power-off
Sep-26-08
 
SUNTelecoms SFP Transceiver supports dual data-rate of 1.25Gbps/1.0625Gbps and transmission distance of 80km with SMF (Single-mode Fiber). The SFP Transceiver consist of two sections: The transmitter section incorporates a FP laser, while the receiver section consists of a PIN photodiode integrated with a trans-impedance preamplifier (TIA).

Features:
Hot-pluggable
Compact size, enabling high port density in each hosting device.
High-performance and cost-effective
SFP package with LC connector
1310nm FP laser and PIN photo detector
80Km transmission with Single-mode fiber
+3.3V single power supply and TTL logic interface
LVPECL compatible data input/output interface
Low EMI and excellent ESD protection
Eye safety, laser Class I safety standard, IEC-60825 compliant
Compatible with RoHS
Feb-28-06
 
Heat shrinkable tube
Cb-hft is a halogen-free, flexible, flame retardant heat-shrinkable tubing. This tubing is low smoke generating, abrasion resistant and in case of burning, no dioxin is produced. Cb-hft can be used in any enclosed area where a flame-retardant, halogen-free enviroment is requied, such as metro, skyscraper, mass transit vehicles and ships. The product is ul recognized and the file no is e180908.

Carton
Jun-23-17
 
Applicable fiber SM (ITU-T G.652), MM (ITU-T G.651), DS (ITU-T G.653), NZDS (ITU-T G.655), others(including G.657)
Cladding diameter 80 -150m
Coating diameter 160 -900
Typical splice loss SM 0.02dB, MM 0.01dB, DS 0.04dB, NZDS 0.04dB
Return loss
28 Telecommunication Infrastructure Equipments Suppliers
Short on time? Let Telecommunication Infrastructure Equipments sellers contact you.
Jun-23-17
 
Technical Specifications1
Wavelength (nm) 1310/1550
Dynamic range (dB)2 38/36, 32/30
Pulse width (ns) 5,20,40,80,160,320,640,1280,2560,5120,10240,20480
Event blind zone (m)3 2m
Attenuation blind zone (m)3 9m
Linearity (dB/dB) ±0.05 dB/ dB
Loss threshold (dB) 0.05
Loss resolution ratio (dB) 0.01
Sampling resolution ratio (m) 0.125 to 8
Sampling point 32K
Distance uncertainty (m) ±(1 m + 510-5 distance + sampling interval)
Distance scope (km) 0.3 to180
Typical real-time refreshing duration (s) 0.2
Memory capacity of trace SD Card (2G), > 10000 pieces
Duration of measurement Defined by user; 5sec, 10sec, 15sec, 30sec, 1min, 2min, and 3min are selectable
General specification
Dimension (HWD) 15023566
Weight 1.5kg
Temperature Running temperature -10 to 50
Memory temperature -40 to 70
Relative humidity 0% to 95% (non condensation)
Power supply Lithium battery; continuing working duration ?¥ 8 hours
Warranty period 12 months
Remarks: 1. The technical specification describes the ensured performance of the instrument when using typical PC model connector to measure. Without considering the uncertainty caused by optical fiber refractivity.2. Dynamic range is the data measured under the condition of the maximum pulse width and 3 minutes of average time. Dynamic range is the data measured under the condition of 180km/20480ns/3min.
3. Measuring conditions of blind zone: reflection event is within 4Km, reflection strength < -35dB. Measured by the minimum pulse width.
Jun-23-17
 
Wavelength(nm) 800~1700nm
Detector InGaAs
Measurement? Range (dBm) -70~+3 -50~+26
Uncertainty ±5%
Calibrated Wavelength(nm) 850,1300,1310,1490,1550,1625
Resolution(dB) 0.01
Optical Connector FC(interchangeable SC,ST) / as well as 2.5mm universal
Power Supply Alkaline Battery(3 AA 1.5V batteries)
Battery Operating Time 240 h with 1.5V Battery(3)
Operating Temperature() -10 ~ +60
Storage Temperature() -25 ~ +70
Relative Humidity 0 to 95% (non-condensing)
Dimension(mm) 200 X90 X50
Weight(g) 285
Jun-23-17
 
Operating wavelength(nm) 1310/1550 (others specify on requests, Max wavelength is 5
Applicable fiber SM ,MM
Laser type FP-LD(others specify on requests)
Maximum Output Power(dBm) -7(can be adjustable, others specify)
Stability(dB, 15min, 20) ±0.1
Stability(dB, 30min, 20) ±0.05
Modulation(Hz) CW, 270, 1K, 2K
Fiber Port FC/PC or FC,SC,ST interchangeable
Alkaline Battery 3XAA, 1.5V
Battery Operating time(h) 45
Operation Temperature() -10+60
Storage Temperature() -25+70
Outline sizemm 200 X90 X50
Weight(g) 285
Jun-23-17
 
Small, light, long battery life
4 motors accurate core alignment
250 times magnification of fiber cores
7s fast splicing, 26s intelligent heating
More than 4000 times electrodes discharging
4400mAh Li-battery, 220 cycles splicing and heating
Inductive automatic heater, not heating without fibers
3 in 1 multi-function clamps, new waterproof structure
Apply to bare fibers, drop cables and jumper wires splicing
Jun-23-17
 
Bare fiber diameter 125m
Outercoat diameter 0.25mm-0.9mm
Fiber type Single tube fiber and Ribbon fiber(exchangeab
Cleaved length 5-30mm
Cleaved angle 0.5°
blade life 48000
Mode Semiautomatic
Dimension 59mm(W)55mm(D)49mm(H)
Weight 257g
Jun-23-17
 
Central Wavelength 650nm±10nm
Emitter Type FP-LD
Output Power 1mw or 10mw
Optical Connector 2.5mm universal connectorFor 1.25mm connectors, FC-1.25mm Hybrid adaptor
can be optional on customer requests
Operating Model Both CW and Pulse(2Hz) available
Power Supply Two AAA alkaline batteries
Battery Operating Time 650nm@1mw 45hours;650nm@10mw15hoursTest with Panasonic LR6 AAA ALKALINE battery
Operating Temperature -10~+60 ()
Storage Temperature -25~+70 ()
Dimension (mm) 115*45*27
Weight 50g(Without Batteries)
Jun-23-17
 
Operating Wavelength 1550nm1310nm Optional
Fiber Type 9/125um SM Fiber
Optical Connector Type FC/PC
Detector Type InGaAs
Peak Power of laser(mw) 60
Max. Displaying Distance Reflection Event(km) 60 (1dB)
Non-reflection Event(km) 20 (2.5dB)
Measurement Unit M
Reflection Event Dead Zone 15m
Distance AccuracyReflection Event ±2m+2*10-4X Distance
Wavelength of VFL Option(nm) 650
Output Power of VFL Option(mW) >=1
Date storage capacity 1000
Communication Port USB
Power Supply Alkaline Battery (3pcs AA 4.5V Batteries)
Battery Operating Time 5000 measurements
Working Temperature() -5~40
Storage Temperature() -10~60
Humidity 0~85%Non-condensation
Dimensions(mm) 200 X 90 X 50
Weightg 320
Jun-23-17
 
Model PON power meter
1310nm 1490nm 1550nm
Pass Zone(nm) 12601360 14701505 15351570
Isolation (dB) >40@1490 >30@1310 >40@1310
Isolation(dB) >40@1550 >40@1550 >40@1490
Measurement Range(dBm) -40+10 -40+10 -40+20
Measurement Accuracy
Connatural uncertainty(dB) ±0.5
Linearity(dB) ±0.1
Passing through insertion Loss(dB)
Jun-23-17
 
Applicable fiber SM (ITU-T G.652), MM (ITU-T G.651), DS (ITU-T G.653), NZDS (ITU-T G.655), others(including G.657)
Cladding diameter 80 -150m
Coating diameter 160 900m
Typical splice loss SM 0.02dB, MM 0.01dB, DS 0.04dB, NZDS 0.04dB
Return loss
Jun-23-17
 
Applicable fiber SM(G.652), MM(G.651), DS(G.653), NZDS(G.655), others(including G.657)
Fiber count Single
Applicable fiber dimensions Cladding diameter: 80 -150m, Coating diameter: 160 -900m
Typical splice loss 0.02dB(SM), 0.01dB(MM), 0.04dB(DS), 0.04dB(NZDS)
Return loss >60db
Fiber cleaved length 10-16mm (coating diameter< 250m ), 16mm(coating diameter: 250-1000m )
Splicing program 40 groups
Operate mode Manual, Automatic
Auto-heating Available
Typical splicing time 8 seconds
Tube heating time 26 seconds for 60mm and 40mm shrinkable sleeves
Fiber view magnification 250X(X or Y view), 125X(X and Y view)
Viewing method and display 2 CMOS cameras, 4.3 inch color LCD monitor
Storage of splice result 4000 results
Loss evaluation Available
Tension test 1.8-2.2N
Interface GUI menu interface, easier operation
Battery capacity 5800mAh, typical 180 cycles(splice and tube heat), pluggable inner Li-battery
Power supply Adaptor, input: AC100-240V(50/60HZ)
Electrode life More than 4000 ARC discharges, can be replaced conveniently
Terminals USB 2.0 port, for uploading splice results and upgrading software
Operating condition Altitude: 0-5000m, Humidity: 0-95%, Temperature: -10â??ï½?+50â??;Wind speed: max 15m/s
Dimension 149mm(L)x120mm(W)x127mm(H)
Weight 1.9kg including battery


Applicable fiber SM (ITU-T G.652), MM (ITU-T G.651), DS (ITU-T G.653), NZDS (ITU-T G.655), others(including G.657)
Cladding diameter 80 -150m
Coating diameter 160 -900
Typical splice loss SM 0.02dB, MM 0.01dB, DS 0.04dB, NZDS 0.04dB
Return loss
Jun-23-17
 
Identified Wavelength Range 800-1700 nm
Identified Signal Type CW, 270Hz±5%1kHz±5%2kHz±5%
Detector Type 1mm InGaAs 2pcs
Adapter Type 0.25 , 0.9, 2.0, 3.0
Signal Direction Left & Right LED
Singe Direction Test Range(dBm, CW/0.9mm bare fiber) -46~10(1310nm)
-50~10(1550nm)
Signal Power Test Range(dBm, CW/0.9mm bare fiber) -50~+10
Signal Frequency Display (Hz) 270, 1k, 2k
Frequency Test Range(dBm, Average Value) 0.9, 2.0, 3.0 -30~0 (270Hz,1KHz)
-25~0 (2KHz)
0.25 -25~0 (1KHz,2KHz)
-20~0 (2KHz)
Insertion Loss(dB, Typical Value) 0.8 (1310nm)
2.5 (1550nm)
Alkaline Battery(V) 2pcs AAA batteries
Operating Temperature() -10�+60
Storage Temperature() -25�+70
Dimension (mm) 196X30.5X27
Weight (g) 195
Dec-17-20
Supplier From Shanghai, , China
Jun-23-17
Supplier From Shanghai, China
Sep-09-10
Supplier From Shanghai, China
28 Telecommunication Infrastructure Equipments Suppliers
Short on time? Let Telecommunication Infrastructure Equipments sellers contact you.