Introductionú¦ 1. Advanced SCM control system enables K3030 system to run steadily. 2. Simple internal design also contributes to steady system running 3. 1448 points waveform fitting is for every cycle, reaching the leading position at home, as has significantly improved the amplitude-frequency Characteristic and voltage-current transient/instantaneous response for the system, with the current transient response of 20 ª¦s. And the transient voltage response of 30 ª¦s, obviously exceeds the China national standard (200 ª¦s). Excellent transient response can be more suitable for the development trend of the new rapid digital type protection relay. 4. 20-digit serial D/A Converter is adopted, and the serial D/A Converter has better linearity and precision than the parallel D/A, greatly increasing the precision of voltage and current signal. 5. 40-220V/0.6A auxiliary DC power supply is under control of software, the power supply can individually provide working power to the protection device or other equipments. Ripple coefficient is less than 0.1% and accuracy is 0.5% Remarkú¦ 1.During the test, amplitude value, phase and frequency are continuously and arbitrarily adjustable with simple operation. Be able to test various types of AC/DC voltage relay, AC/DC current relay, frequency relay, power relay, impedance relay, harmonic relay, differential relay and synchronism relay about operate time and operate value by manual or by machine;Faults-Simulation enables users to calibrate fixed values of distance protection device and zero-sequence protection device. And fault simulations also lead to distance relay test of distance protection device and zero-sequence protection device. And K3066 can auto-scan the ratio restraint curve of differential protection in microcomputer and digital transformer as well as Generator-transformer Set. 2.The installation of particular heating radiator contributes to the reliable practicability of K3030.There are four high-power ventilating fans inside the Host. Thermal-shutdown is adopted to ensure the excellent stability & reliability of the amplifier even under long-playing working state along with high current. Current generator provides the function of open-circuit protection and open-circuit alert in itself. While Voltage generator possesses the functions of short-circuit protection, of output testing against waveform distortion, of Auto-recognition & Auto-alarming & Self-lock protection against misconnecting as well as the function of Dynamic Waveform Monitor&Display.. 3.Possess isolated input contacts, and the same case for idle contacts and electric potential contacts; and well adapt to various wiring installation. 4.Four voltage output channel, of which one channel is set as auxiliary DC supply by software, making it more convenient for field debugging. 5.Internal design is of architectural style framework and of shock & impact resistance external box made of high intensity aluminum alloy enables the equipment subject to rigid vibration 6.Be able to work as DC generator to provide Relay Protection Device with DC Voltage Generator(0í¡220V) 7.Direct edition on test report when using PC, and that scanning graph can be added into test report is useful for report analysis. Weight:24KG Dimensions:420ú¿Dú¬í-140 (W)í-360 (H) mm
Hour meter This hour meter is mechanical type.Widely applied in each kind of machine, equipment and device(such as environmental protection equipment generator etc). Used for to demonstrate the machine, the equipment, the device accumulation operating time. It is mechanical type accumulation, the longest time for accumulation time can be 11 years. It still can maintain the data after the power cut. Itemno. Bz142-1 bz142-2 bz142-3 Operating voltage ac 24-450v ac 24-450v dc 10-80v Ferquency 50hz 60hz Time range 0-99, 999.99h Dimension 48 x 48 x 40mm Net weight 50g Mounting insert type
Description: Contact rating:3a, 3c Contact material:sliver alloy Contact capacity:10a 220vac/28vdc Nominal coil power: 1.4w, 2.5va 385*190*300mm n.W:14kg
JR28(LR2-D) series thermal relay is suitable for using in the main circuits rated voltage up to 660V,rated current 93 A, AC 50Hz or 60Hz,for over-voltage protection of AC motor. The relay has the differential mechanism and temperature compensation and can plug in CJX2(LC1-D) series AC contactor, also be independently fixed. Specifications: LR2-D13, D23,D33
JRS1(LR1-D) series thermal relay is suitable for using in the circuits rated voltage up to 600V,rated current 93A.AC 50Hz or 60Hz for over-voltage protection of AC motorú«The relay has the differential mechanism and temperature compensation and can plug in CJX2(LC1-D) series AC contactor, also be independtly fixedú« Specification: LR1-D09, D40,D63,D80 Rated voltage: 220, 380, 415, 440, 660V Rated current: 0. 1~0. 16, 0. 16~0. 25, 0. 25~0. 40, 0. 40~0. 63, 0. 63~1, 1~1. 6, 1. 6~2. 5, 2. 5~4, 4~6, 5. 5~8, 7~10, 10~13, 13~18, 18~25, 23~32, 30~40, 38~50, 48~57, 57~66, 63~80A
JRS2(3UA) series thermal overload relay are suitable for overload and phase-failure protection of AC motors with frequency of 50/60Hz,voltage up to 690-1000v,current up to 0.1-400A under 8-hours duty or uninterrupted duty. Several functions provided by these relays are: phase-failure protection, temperature compensation, ON/OFF indication and manual/automatic reset. The relays can be mounted onto contactors or installed as single units.
Relays Miniature, contact load capacity up to 30a, 40a Terminal types as inserting Coil voltage:6, 12, 24 Contact arrangement:1a, 1b, 1c, 2a, 1u Outline size:29x29x25.6mm Weight:36g
Rated voltage:12v Pins:6 The pins and fixator made of cooper. Packing by buyers needing
Relay Electromagnetic relay: jqx-7ma, jqx-7mb, jqx-008m, jqx-030m, jqx-030mc, jqx-030md, jqx-117m, jqx-128m, jqx-132m, jqx-136m, jqx-136md, jqx-142m, jqx-142ma, jqx-164m, jqx-168m, jqxh-167m, jrc-4m, jrc-5m, jrc-10m, jrc-071m, jrc-089m, jrc-123m, jrc-129m, jrc-131m, jrc-152m, jrc-154m, jrw-3m, jrw-114m, jzc-064m, jzc-064ma, jzc-078m, jzc-084m, jzc-090m, jzc-097m, jzc-098m, jzc-102m, jzc-102ma, jzc-130m, jzc-134m, jzc-158m, jzx-012m, jzx-127m, jzx-127ma, jzc-145m, kjrc-071m, kjrc-105m, kjzc-064ma, kjzc-078m, Thermostat relay :juc-1m, juc-068m, juc-1m-jx, juc-027m, juc-027ma, juw-149m, juc-079f, juc-079fa, juc-079ft, juc-054m, juc-083m, juc-083ma, juc-121f, juc-162f, juc-066m Time relay : jsb-184m Rfcoaxialrelays:, jpt-161m Sealedelectromagnetic relay :jmc-022m, jmc-069m, jmc-099m, jmc-099ma, jmc-104m, jmc-135m, jmc-153m, jmc-157 Special relay: bk15-1 , gk-2, gk-1, gk-3, gk-5, gk-6, jf-1,
Time relay can be widely used in machines and equipment needing self-control of high precision and reliability. It is characteristic of small size, light weight, compact structure, high dependable and efficient,long life,etc.
Thermal relays (1)lr1, lr2 series thermal relay It is suitable for using in the circuits rated voltage up to 660v, rated current 93a ac 50hz or 60hz, for over-voltage protection of ac motor. (2)jrs2 (3ua) series thermal relay It is suitable for using in the circuits rated voltage up to 600-1000v and current up to 630a. Leave factory packing
4 channel power distribution for H51X, H51q for extension rack F-BASE RACK 11 inclusive miniature fuse 5x20, 4 A-T, H
Product Parameter 1. It can output three-phase 0-500a current at the same time. 2. It can synchronously test the action time of thermal relay thermocouple and motor protector. 3. Normally open and normally closed contact detection. 4. Several calibrations can be connected in series at the same time to improve working efficiency. Product Parameter 1. AC current output: 0-500a (customizable) 2. Digital AC ammeter: 4 0.5 class accuracy A. Digital timer Timing length: 0 ~ 999.999 seconds Error: class 0.2 accuracy B. Boundary dimension: 44 30 34cm C. Weight: 7kg
Product Introduction SF6 switch is a widely used high voltage electrical appliance in the power system. SF6 gas density relay is an important element used to monitor the variation of SF6 gas density in the SF6 switch body during operation. Its performance directly affects the operation safety of SF6 switch.Due to the infrequent operation of SF6 gas density relay in the field it is often found that the operation is not flexible and the contact contact is not good after a period of time and some of the temperature compensation performance of the density relay becomes worse. When the ambient temperature changes suddenly the SF6 density relay often misoperates.Therefore DL/T596-2005 "precautionary test regulations for power equipment" stipulates that each SF6 switch user should verify SF6 gas density relay regularly.From the perspective of actual operation it is necessary to carry out regular calibration of SF6 density relay and pressure gauge in field operation. The check pressure sensor with high precision and high speed A/D converter combining with the 32 bit high performance microprocessor can check the performance of A variety of SF6 gas density relay can accurately measure the movement of the signal when the current temperature pressure value arbitrary automatically when the environment temperature of 20 â?? conversion standard pressure and have A print store and U disk offload function at the same time the fault in the process of automatic identification test.Sf6 gas density relay calibrator is convenient to carry simple to operate high test accuracy strong stability and good reliability which reflects the characteristics of "intelligent" instrument.
Product Introduction Single Phase Relay Test Set General TKJB SINGLE PHASE RELAY TEST SET is a portable field testing equipment with excellent performance; Elegance and polished appearance with aluminum alloy chassis and PC panel, within the ARM chip control, LCD screen display voltage and current output stopwatch, it could output a full isolation way for adjustable AC/DC voltage, and AC/DC current and a way for adjustable DC voltage; the output loop with double overload protection with large output capacity ,small volume, light weight, high reliability ,It Suitable for field calibration and test for various relay. Product Characteristics Single Phase Relay Test Set Main Features 1 Output a full isolation way for adjustable DC voltage, Automatic protection for short circuit, overload and out range. 2 Maximum Output Current:0150Aã?? 3 Equipped with LCD digital AC/DC volt-ampere meter, can show the AC and DC voltage and current values, stopwatch, potential, contact state. 4 Internal electric stopwatch; Available electrical contacts, maximum potential 250V; Dual channel measurement. 5 Light-weight design, small-volume, and fully-functional.
Product Parameter 1. It can output three-phase 0-500a current at the same time. 2. It can synchronously test the action time of thermal relay thermocouple and motor protector. 3. Normally open and normally closed contact detection. 4. Several calibrations can be connected in series at the same time to improve working efficiency. Product Parameter 1. AC current output: 0-500a (customizable) 2. Digital AC ammeter: 4 ½ 0.5 class accuracy A. Digital timer Timing length: 0 ~ 999.999 seconds Error: class 0.2 accuracy B. Boundary dimension: 44 30 34cm C. Weight: 7kg
1. Standard 4-phase voltage and 3-phase current output with 4-phase voltage and 3-phase current output can conveniently carry out various combination outputs for various types of protection tests. Single-phase voltage can output up to 120V single-phase current up to 40A (10 seconds) current three and can output up to 120A the fourth phase voltage Ux is a multi-function voltage item can be set as 4 kinds of 3U0 or check the same period voltage or a certain voltage value of the case output. 2. Single machine is easy to operate. The single machine is operated by a convenient and flexible rotating mouse through a large LCD screen all of which are displayed in Chinese. It can complete most of the field test verification work can verify all kinds of relays and microcomputer protection and can simulate all kinds of complex transient permanent and transformational faults for the whole group of tests. Boot can be used easy to operate. 3. Double operation mode connected to the computer operation through the Windows platform of the full set of Chinese operating software can carry out a variety of large complex and higher degree of automation verification work can be easily tested and scanned a variety of protection fixed value can be real-time storage test data display vector diagram draw fault waveform online print report etc. 4. Software is so powerful that can complete all kinds of high degree of automation of large complex check work such as three phase differential test auxiliary power fast cutting prepared from the cast test line protection inspection period reclosing etc. can easily test and scanning protection setting various fault playback real-time storage test data show that the vector diagram online printing report etc. 5. Switch quantity contact is rich three - phase for 7 contact input and 2 pairs of empty contact output. The input contacts are compatible with 0 ~ 250V potential contacts and can be identified automatically. Input and output contacts can be expanded according to user needs. 6. Large screen LCD display microcomputer relay protection tester adopts 320Ã??240 lattice large screen high-resolution graphics LCD display all the operation process are set on the display screen the operation interface and test results are displayed in Chinese the display is intuitive and clear. 7. Self-protection adopt reasonable design of heat dissipation structure and have a variety of reliable and perfect protection measures and power soft start and a certain fault self-diagnosis and locking function. 8. With an independent dedicated dc power output the device is equipped with one 110V and 220V dedicated dc power output. 9. High cost performance belongs to the cross - professional joint design products integrated multi - professional advanced scientific and technological achievements. Both large tester performance and small tester price with a high performance ratio.
Product Introduction Single Phase Relay Test Set General TKJB SINGLE PHASE RELAY TEST SET is a portable field testing equipment with excellent performance; Elegance and polished appearance with aluminum alloy chassis and PC panel, within the ARM chip control, LCD screen display voltage and current output stopwatch, it could output a full isolation way for adjustable AC/DC voltage, and AC/DC current and a way for adjustable DC voltage; the output loop with double overload protection with large output capacity ,small volume, light weight, high reliability ,It Suitable for field calibration and test for various relay. Product Characteristics Single Phase Relay Test Set Main Features 1 Output a full isolation way for adjustable DC voltage, Automatic protection for short circuit, overload and out range. 2 Maximum Output Current:0150A 3 Equipped with LCD digital AC/DC volt-ampere meter, can show the AC and DC voltage and current values, stopwatch, potential, contact state. 4 Internal electric stopwatch; Available electrical contacts, maximum potential 250V; Dual channel measurement. 5 Light-weight design, small-volume, and fully-functional.
TKRJ- electronic thermal relay calibration is mainly used for setting and calibration of various thermal relays and motor protection devices. Because of its reasonable design convenient operation and high output power it is widely used in electric test sites of power system railway petrochemical metallurgical and mining enterprises. 1. It can output three-phase 0-500a current at the same time. 2. It can synchronously test the action time of thermal relay thermocouple and motor protector. 3. Normally open and normally closed contact detection. 4. Several calibrations can be connected in series at the same time to improve working efficiency.
Product Introduction Single Phase Relay Test Set General TKJB SINGLE PHASE RELAY TEST SET is a portable field testing equipment with excellent performance; Elegance and polished appearance with aluminum alloy chassis and PC panel, within the ARM chip control, LCD screen display voltage and current output stopwatch, it could output a full isolation way for adjustable AC/DC voltage, and AC/DC current and a way for adjustable DC voltage; the output loop with double overload protection with large output capacity ,small volume, light weight, high reliability ,It Suitable for field calibration and test for various relay. Product Characteristics Single Phase Relay Test Set Main Features 1 Output a full isolation way for adjustable DC voltage, Automatic protection for short circuit, overload and out range. 2 Maximum Output Current:0150Aã?? 3 Equipped with LCD digital AC/DC volt-ampere meter, can show the AC and DC voltage and current values, stopwatch, potential, contact state. 4 Internal electric stopwatch; Available electrical contacts, maximum potential 250V; Dual channel measurement. 5 Light-weight design, small-volume, and fully-functional.