Disposable plastic cpda-1 blood bag mainly compose collection bag,best sale bags and relevant anticoagulant. Single cpda-1 blood bag is used for collection, preservation and transfusion of whole blood, Multi-cpda-1 blood bag is mainly used for collecting whole blood land for separation, preservation and transfusion of red blood cell, plasma and platelet etc.
Sterile Urine bag for single use Size: 1000ml Product structure: plastic protector for conical fitting, conical fitting, soft tube, pouch for storing drug, plastic protector, two way connector etc. Product instruction: The products are made by medical polymer materials. Sterilized by EO gas; sterile, non-toxic, pyrogen free. Technical indication: Pouches of the products are used for storing rubbish fluid conveniently in surgical clinic. Scope for use: The products are used for surgical drainage storage in clinic
Sterile insulin syringe for single use ( with needle) Sizes: 0.5ml, 1ml. SPEC: U-40, U-80 Product structure: barrel, plunger, piston, and sterile hypodermic needle Product instruction: The products are made by medical polymer materials. Sterilized by EO gas; sterile, non-toxic, pyrogen free. The needles on barrels are dead space, without residual volumn, ultra thin wall needle cannula, highly sharp needle point, clear and accurate graduation. This makes easy identification, no counting and accurate medication dosage. And the double-wall sealed package makes easy bringing safe use. Technical indication: in accordance with GB15810 Scope for use: The products are used for the injection of insulin drug.
Sterile Vacuum blood collection tube for single use: Sizes: 1ml, 2ml, 3ml;, 5ml, 10ml. SPEC: non-additive, additive. Product structure: test tube, piston, plastic cap. Product instruction: The products are made by medical glass, or highly transparent medical plastic materials. The products are matched with vacuum blood collection sets, and used as per the theory of negative pressure, and suck blood into the storage tube by the connecting tube, and can step the way of one vacuum blood collection needle with more storage tubes. Technical indication: Additive dosage of the products are accurate, blood sample capacities are also accurate. Scope for use: The products are used for collecting blood in clinic
Sterile infusion set for single use Model: infusion set: GB8368 IS-V infusion set: GB8368 IS-NV Product structure: plastic protector for spike, spike, air-inlet, soft tube, drip chamber, flow regulator, fluid filter, and injection site for adding fluid drugâ?¦etc. Product instruction: The products are made by medical polymer materials. Sterilized by EO gas; sterile, non-toxic, pyrogen free. The products are made by medical soft materials surface is sound and transparent. Technical indication: in accordance with GB8368 and ISO8536-4. Scope for use: The products are used for intravenous gravity infusion.
Safety Slide Insulin Syringe EO Sterilization Refer Standards EN ISO 8537:2007 Sterile single-use syringes, with or without needle, for insulin. EN ISO 9626:1991 / AMD. 1: 2001 Stainless steel needle tubing for the manufacture of medical devices AMENDMENT 1. ASTM F88/F88M-09 Standard Test Method for Seal Strength of Flexible Barrier Materials. ASTM F1140/F1140M -13 Standard Test Methods for Internal Pressurization Failure Resistance of Unrestrained Packages. ISO 10993-7:2008 Biological evaluation of medical devices - Part 7: Ethylene oxide sterilization residuals. USP 37- NF32 2014: U.S. Pharmacopeia National Formulary.
Insulin Syringe EO Sterilization Refer Standards ISO 9626: 1991 + AMENDMENT 1 2001 Stainless steel needle tubing for the manufacture of medical devices. ISO 8537:2007 Sterile single-use syringes, with or without needle, for insulin. ISO 10993-7:2008 Biological evaluation of medical devices - Part 7 : Ethylene oxide sterilization residuals. ASTM F 1140/F 1140M-13 Standard test methods for internal pressurization failure resistance of unrestrained packages. USP 37-NF 32 Bacterial Endotoxins Limit. ISO 11737-2:2009 Sterilization of medical devices - Microbiological methods - Part 2: Test of sterility performed in the definition, validation and maintenance of a sterilization process. ISO 11135-1:2007 Sterilization of health care products - Ethylene oxide - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices.
Serum Blood Collection Tube Golden Vac serum blood collection tube promises to provide non-polluting and non-different original blood specimen for medical test. After centrifugation, serum can be separated from blood cells and fibrin effectively. Serum tube includes 3 kinds of tubes: 1. Plain Tube with red cap, 2. Pro-coagulation Tube with red cap, 3. Gel&Clot Activator Tube with yellow cap Plain Tube aims to obtain serum specimen forbiochemistry, immunology and serology tests in clinical inspection. Its main merit is that serum separate out of blood cells and fibrin naturally, so its physico-chemical properties are keeping nonpolluted. The intact serum is suitable for a wide range of laboratory operation, routine clinical chemistry, immunology and serology. Item No . GD020A , Specification Red cap, Plain, 13*75mm, 2ml Item No . GD030A , Specification Red cap, Plain, 13*75mm, 3ml Item No . GD040A , Specification Red cap, Plain, 13*75mm, 4ml Item No . GD050A , Specification Red cap, Plain, 13*75mm, 5ml Item No . GD060A , Specification Red cap, Plain, 13*100mm, 6ml Item No . GD070A , Specification Red cap, Plain, 13*100mm, 7ml Item No . GD090A , Specification Red cap, Plain, 16*100mm, 9ml Item No . GD100A , Specification Red cap, Plain, 16*100mm, 10ml Item No . GD090AR , Specification Rubber stopper, Plain, 16*100mm, 9ml Item No . GD100AR , Specification Rubber stopper, Plain, 16*100mm, 10ml
Whole Blood Collection Tube Golden Vac whole blood collection tube promises to provide non-polluting and non-differential original blood specimen for medical test, does not require separation of plasma or cells. It includes 2 kinds of tubes: EDTA Tube with Purple cap, ESR Tube with black cap. EDTA Tube is widely used for clinical haematology test, especially for routine blood examination. Our automatic sampling instrument finely and accurately spray additives onto the interior tube wall, to ensure the mixing speed and the anticoagulation effect. EDTA Tube is very convenient to use for it can be directly put on the analyzer to detect without openning the cap. Item GD020EK3 , Specification Purple cap, EDTA K3, 13*75mm, 2ml, Item GD030EK3 , Specification Purple cap, EDTA K3, 13*75mm, 3ml, Item GD040EK3 , Specification Purple cap, EDTA K3, 13*75mm, 4ml, Item GD050EK3 , Specification Purple cap, EDTA K3, 13*75mm, 5ml, Item GD060EK3 , Specification Purple cap, EDTA K3, 13*100mm, 6ml, Item GD070EK3 , Specification Purple cap, EDTA K3, 13*100mm, 7ml, Item GD080EK3 , Specification Purple cap, EDTA K3, 16*100mm, 8ml, Item GD090EK3 , Specification Purple cap, EDTA K3, 16*100mm, 9ml, Item GD0100EK3 , Specification Purple cap, EDTA K3, 16*100mm, 10ml, Item GD080EK3R , Specification Rubber stopper, EDTA K3, 16*100mm, 8ml, Item GD090EK3R , Specification Rubber stopper, EDTA K3, 16*100mm, 9ml, Item GD0100EK3R , Specification Rubber stopper, EDTA K3, 16*100mm, 10ml, Item GD020EK2 , Specification Purple cap, EDTA K2, 13*75mm, 2ml, Item GD030EK2 , Specification Purple cap, EDTA K2, 13*75mm, 3ml, Item GD040EK2 , Specification Purple cap, EDTA K2, 13*75mm, 4ml, Item GD050EK2 , Specification Purple cap, EDTA K2, 13*75mm, 5ml, Item GD060EK2 , Specification Purple cap, EDTA K2, 13*100mm, 6ml, Item GD070EK2 , Specification Purple cap, EDTA K2, 13*100mm, 7ml, Item GD080EK2 , Specification Purple cap, EDTA K2, 16*100mm, 8ml, Item GD090EK2 , Specification Purple cap, EDTA K2, 16*100mm, 9ml, Item GD0100EK2 , Specification Purple cap, EDTA K2, 16*100mm, 10ml, Item GD080EK2R , Specification Rubber stopper, EDTA K2, 16*100mm, 8ml, Item GD090EK2R , Specification Rubber stopper, EDTA K2, 16*100mm, 9ml, Item GD0100EK2R , Specification Rubber stopper, EDTA K2, 16*100mm, 10ml, Item GD035EK3G , Specification Purple cap, EDTA K3 + Separate Gel , 13*75mm, 3.5ml, Item GD060EK3G , Specification Purple cap, EDTA K3 + Separate Gel , 13*100mm, 6ml, Item GD085EK3RG , Specification Rubber stopper, EDTA K3 + Separate Gel , 16*100mm, 8.5ml, Item GD085EK3G , Specification Purple cap, EDTA K3 + Separate Gel , 16*100mm, 8.5ml,