Product description The impulse voltage generator intelligent measurement and control system is the latest programmable control system and consists of two parts: Automatic control of pulse voltage generator program and automatic analysis of pulse signal measurement. The General Conditions of Use Altitude: 1000m Ambient temperature: 5 40 Relative humidity: 90 20 Use of the environment: indoor Non-conductive dust Grounding resistance 0.5 No fire or explosion hazard Earthquake resistance: 8 magnitude There is no gas that corrodes metal and insulates Impulse voltage generator (2) Supply voltage waveform is the actual sine wave, waveform distortion rate 85% (more than 90% when no load 300PF); (2)Truncated wave: cut-off time (2-6) 10% , zero-crossing coefficient 0.3% (3)Standard operating impulse voltage wave 250 20% s / 2500 60% s, The impulse voltage waveform parameters and their deviations are in line with the requirements of the national GB311 and GB16927 standards.
Overview Three-phase phase volt-ampere meter a high precision instrument for measurement of three-phase electric parameters, it can be used to measure the three phase voltage, current and phase angle, frequency, power, power factor and so on. three-phase digital volt-ampere phase meter adopt high-speed Cortex M3 processor and 24 bits high-speed ADC a for measuring and calculation , A complete graphical interface, true color display with resolution of 320 x 240 and touch screen operation make a friendly man-machine interface. It is easy to carry
Products Introduction Very Low Frequency high voltage generator 30KV combines advanced technologies such as modern digital conversion, full computer control, automatic voltage increase, voltage reduction, measurement and protection. In the automatic upgrade process, human intervention can be taken care of. The main advantages include full electronics, small size, light weight, large-screen LCD display (clear and intuitive), printer output test report, and easy use. Technical Parameter
Product description The impulse voltage generator intelligent measurement and control system is the latest programmable control system and consists of two parts: Automatic control of pulse voltage generator program and automatic analysis of pulse signal measurement. The General Conditions of Use Altitude: 1000m Ambient temperature: -5 40 Relative humidity: 90 20 Use of the environment: indoor Non-conductive dust Grounding resistance 0.5 No fire or explosion hazard Earthquake resistance: 8 magnitude There is no gas that corrodes metal and insulates Impulse voltage generator (2) Supply voltage waveform is the actual sine wave, waveform distortion rate 85% (more than 90% when no load 300PF); (2)Truncated wave: cut-off time (2-6) 10% , zero-crossing coefficient 0.3% (3)Standard operating impulse voltage wave 250 20% s 2500 60% s,
Products Introduction VLF high voltage generator 60KV.The capacity of it is 1/500 of tradition way. Greatly simplify testing procedures, That is why commonly used in the developed , s ministry of electric power entrust Wuhan high voltage research institute to drafting 35Kv and below XLPE insulated power cable ultra-low frequency (0.1Hz) voltage withstand test methods for promoting this approach. The instrument is developed according to made of this need. It can be widely used in cable, large-scale high-pressure rotary motor, power capacitors into AC voltage withstand test. Power capacitance of single-core XLPE insulated cable (F/km) 0.1Hz -60KV Ultra-Low Frequency High Voltage Generator Model Rated Voltages Load capacity Fuse Weight Useful VLF-60 60kV (peak ) 0.1Hz,0.5F 25A Control 6 HV TANK-30 HV TANK-II33 25KV and below the cable
NetSure501 A41 NetSure701 A41 Embedded High-Frequency Switching Mode Power System Series Emerson NetSure701 A41-S3 48V 200A Rectifier Power System.
Emerson/Vertiv Netsure701 A41-S10 Telecom Power Supply System Rectifier R48-2000A3/R48-2000E3. Original new Emerson 9U 200A power supply NetSure701 A41-S10 network psu.
Emerson Embedded DC Power System Netsure531 A41-S2 Emerson/Vertiv Netsure 531A41-S2 Telecom Power Supply System Rectifier R48-2000A3/R48-2000E3.
Flatpack S Intrepid Series 1U High-Efficiency DC Power System APPLICATIONS The Eltek Flatpack S 1U system is a high-efficiency power solution with an optimal footprint for applications where space is limited both in racks and various cabinet installations. The Flatpack S 1U is a one rack-unit high system that delivers 48V DC power to telecom infrastructure that includes: 4G/LTE, FTTx, distributed antenna systems (DAS), microwave broadband, cable broadband, telephony servers and switches, and fiber-optics. PRODUCT DESCRIPTION The compact size of the system makes it perfect for use in 19" or 23" wide racks and cabinets. Built as a plug-and-play system, the Flatpack S 1U reduces installation time and enables cost-effective deployment.
Pearl River SMR3004H communication power supply module SMR3004HE rectifier module
ZTE DCPD6 DC 48V 100A Power Distribution Box
ZTE Embedded Power System ZXDU68 B401
Zxdu68 B301 Embedded Dc Power System
ZTE POWER A Power board for ZTE ZXJ10 PSTN
ZTE ZXDU68 B201 Embedded DC Power Supply 48V 200A
Original ZTE 48V DC Embedded Power System Cabinet ZXCTN6220
Delta 1U Embedded Switching Power Supply System DPS1800-48/30
Wholesale Supply Original 48v 150a Embedded Power System
Original Delta 48V 300A Embedded Power System MCS3000D-48V/50(300A)
MCS1800 -48 VDC/120 Amps, or +24VDC/200Amps, N+1 redundancy Modular design for scalable, cost-effective expansion Front access for simple installation and maintenance High power density Active Power Factor Correction (>. 99PFC) High-efficiency Temperature-compensated float voltage control Alarm Control Unit Low Voltage Battery Disconnect (LVBD) (System equipped with PDU) Remote Monitoring and control