CB-212 is advance three phase 3 wire APFC display provide user-friendly interface and ease of access to parameters for manual setting built-in power analyzer allowing the instantaneous display of any electrical parameter (voltage current reactive power harmonics etc. With THD protection function not affected by the harmonics can protect capacitor from harmonic interference. Max 12 step control 5A/250V relay output or 12VDC output. Optional RS-485 communication port easy for user connect to PLC and build SCADA system. Higher measurement accuracy(0.5) and system stability it is cost effective ideal for OEMs and panel builders solution. FEATURES I / U / KW / KVAR / HZ / COS measurement and display 93*70 LCD display Anti-harmonic design Max 12 steps capacitor control
CD-212 is ready for operation with its preset functions immediately after installation without any modifications or adjustments. With smart switching control identifies the power of the connected capacitor stages and connects or disconnects them in an optimized manner as required by the actual mains conditions. This guarantees that optimum power factor correction is achieved with the minimum number of switching operations. Dynamic compensation response time less than20ms work with static contactor provide zero-crossing switching and harmonic protect function Suitable for welding steel rolling machinery cranes oil field pumping units wind power generation piling machines and other varies equipment with large instant impact system. With RS485 communication port can control extra 3 sets CD-212 build Max 48 step control. FEATURES Automatic detect electrical network system status, do not need special configuration Large size TFT LCD display, one screen can show more info than segment LCD screen Various automatic protection functions can make sure capacitor bank long term working With basic electrical parameter measurement and display (I / U / KW / KVAR / KVA / HZ / COS) Provide power quality statu display (Current & Voltage wavefrom and 2-31th Harmonic) Record past 4 days site Power factor trend, display in visualization graph
CP-PF series meter using on single phase or 3- phase system measure cos Ï?i, has a moving coil meter movement that shows by an electronic circuit the phase shift between voltage and current (cos. Ï?). Scales are available between 90° and 360° phase shift, as well as capacitive and inductive. FEATURES M4 screw connections with clamps make this easier Clamping the connecting wires. Housing use matiral match UL94V-0 standard All fastenings suitable for shaking and shock resistance. Accept special customization requirements
CP-W and CP-var analog power meter consists of a moving coil meter with installed transducers which measures the active / reactive power in a sinusoildal or not sinusoidal current circuit and which transformes it into an analogue signal. This is then passed to the moving coil movement. FEATURES M4 screw connections with clamps make this easier Clamping the connecting wires. Housing use matiral match UL94V-0 standard All fastenings suitable for shaking and shock resistance. Accept special customization requirements MODELS Ordering info Measurement range (Include CT/VT ratio) Overload (Amp/voltage reading) Accuracy class Operation frequency Marine use or not
KLY meters are direct acting analog electrical measuring instruments. They are mainly used on the distribution, control panel of power plant and other different apparatus to measure current, voltage, frequency, power, power factor, synchroscopes. Phase sequence and other non-electric values The digital meters measure and display the current, voltage, frequency, power, power factor in electric power network and automation control system Operating Temperature KLY Series:-25C~+55C CP Series:-20C~+40C Storage Temperature -40C~+70C
CP-PF series meter using on single phase or 3- phase system measure cos Ï?i, has a moving coil meter movement that shows by an electronic circuit the phase shift between voltage and current (cos. Ï?). Scales are available between 90° and 360° phase shift, as well as capacitive and inductive. FEATURES M4 screw connections with clamps make this easier Clamping the connecting wires. Housing use matiral match UL94V-0 standard All fastenings suitable for shaking and shock resistance. Accept special customization requirements
DCEM energy meter is an advanced solution for multi-channel DC system. It can visually display voltage, current, power data and energy cumulative data. With a panel keypad, it can set voltage display parameters and the DC shunt parameters. With RS485 communication interface, DCEM can be connected to the monitoring center. It is a high-performance automatic meter suitable for UPS system detect, Solar energy plant monitor, industrial and mining enterprises, civil construction, building automation etc. Features ·External Hall sensors for isolation current input, higher safety security ·Max 4 channels energy detect & display. ·Multi-use LCD screen for volt / amp / energy data. ·Built-in isolation circuitry can measure the maximum 1KV voltage signal. ·Provide 4 channels DI port, 2 channel DO for control. ·Provide RS485 port for remote communication.
New 194J series Smart Power Manager is the more powerful meter than 194Y series power analyzer. With higher precision and more measurement parameters. This meter is the latest series meter developed in 2015 by Blue Jay tech. It is the ideal choice for monitoring and controlling of power distribution systems. Application ·Provide remote fire alarm. ·Temperature data reading. ·Harmonic analyze. ·Remote data reading. ·Alarm station with voltage-free digital inputs. Features ·Class 0.2 power and energy ·Current measuring .../5 or .../1 A ·Backlit LCD display ·Expandable input / output modules (up to 3 modules) ·With RS-485 Modbus/RTU Communications ·Measured varies of power parameter. (Max demand/unbanlance/crest factor/K factor...) ·Optional 2 channel Digital Input (DI) and 3 channel Digital Output (DO) ·Record and read multi- tariffs ratio, Up to 3 months ·Provide max 50 lists SOE record function ·ITF Technology: galvanic insulation protection inputs outputs ·Universal series power supply (85-265VAC/DC)
Three phase electrical network power quality detection device, provide energy consumption and generate; THD (Total Harmonic Distortion); Harmonic individual data reading. Build-in 4 tariffs energy logger function, with onboard memory can record last three month energy data, free to set max 12 segment record period, can be use as a commercial billing unit. Application ·Applied to the control of general switch boards and low, medium and high voltage connection points. ·Harmonic analyze. ·Remote data reading. ·Alarm station with voltage-free digital inputs. Features ·Class 0.5S power and energy ·Current measuring .../5 or .../1 A ·Backlit LCD display ·Expandable input / output modules (up to 3 modules) ·With RJ45 Ethernet port support Modbus-TCP Communications ·With 2 channel Pulse Output (PO) for active energy&reactive energy counting ·Optional 1 channel Analog Output (AO) ·Optional 4 channel Digital Input (DI) and 2 channel Digital Output (DO) ·Record and read multi- tariffs ratio, Up to 3 months ·ITF Technology: galvanic insulation protection inputs outputs ·Universal series power supply (85-265VAC/DC)
BJ-192/193 series especially developed for indication and supervision of the three-phase circuit, replaces an analogical display meter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of single phase and three-phase networks, it is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password. Title goes here. ·Class 0.5(192 series)/0.5S(193 series) electrical parameter measurement ·Current measuring .../5 or .../1 A ·Measurement function cover: Current, Voltage, total three-phase power, power factor, frequency ·RJ45 Ethernet MODBUS-TCP Communications ·Expandable input / output modules (1 modules) ·ITF Technology: galvanic insulation protection inputs outputs ·Large character LED Screen display ·Optional various install sizes
Modular DIN Rail Products offer a wide range of functions to be integrated in electrical installations with significant benefits for the user. It is designed for high level performance and are safe and fast to install. Blue Jay have a complete range of DIN-mounted electricity meters for different applications, together with a wide range of communication options. The meters are quick and easy to install due to their DIN-rail mounting. It is highly accurate, durable, reliable, lower power consumptive, without reversion, creep proof, anti-tanmpering and bilateral recoring with strong overloading capability. It conforms to the related Chinese requirement of GB/T17215.321-2008 and International requirement IEC62053-21 also pass EMC and LVD. Real-time measurement: voltage, current, power, power factor, frequency, Time-of-use metering of forward and reverse active energy, four-quadrant reactive energy; Maximum 4 tariffs; with 1 active pulse output; Automatic settlement function (with a storage of 12 months history records); Optional Event logging function (power on, power down, zero clearing, demand clearing, programming, timing events); Optional 2 channels switching value inputs, 1 electromagnetic relay outputs; Optional 1 channel 12V, 50 mA DC power supply output; Voltage and current ratio range: 0.0000~9999.9999; Abundant programmable alarm outputs; RS-485 supporting Modbus RTU protocol and DL/T645 protocol, self-adaptive; Indication prompts for voltage broken phase, inverse phase sequence, communication and other status; Configurable cyclic display items; Completely enclosed design, dust proof and antifogging. Interface electrical performance: Optocoupler relay output interface: AC/DC 250V,100mA Switching value input interface: Conductor Resistance 1.2KΩ Transmitter output interface
The 19D-301 three-phase DIN-rail energy meter is an intelligent device for medium and low voltage systems (6-35KV and 0.4KV). It integrates data collection and control functions, provide LCD display show three-phase AC power measurement and calculation, consumption energy value. In addition, 19D-301 also provide optional function, user can choose multi-tariff record, Maximum Demand record, relay alarm output(1 channel) for different site condition. RS485 port support MODBUS-RTU or DL/T645-2007 protocol (can be customized). features: 1.- Central display area: mainly displays measurement data. Energy, current, voltage, power, power factor, frequency, timer (depends one different sub-model, display value may parts of above parameter). 2.- Four LED indicators: Show meter condition (accept customized). 3.- Four keys button: for user set operation.
BJ194E-9S4, with its four direct access keys and LED displays, helps you use all the parameters in 3P3W or 3P4W LV installation. These parameters can be centralized on a PC or PLC through an RS 235 link using MODBUS protocol. The casing is designed so that the installer can easily fit the meter to the door of a cabinet. Applications 1. Metering of distribution feeders, transformers, generators, capacitor banks and motors 2. Medium and low voltage systems 3. Commercial, industrial, utility Features 1.Class 0.2 or 0.5 power and energy 2.Current measuring .../5 or .../1 A 3.Option RS-232 Modbus/RTU Communications 4.Expandable input / output modules (up to 3 modules) 5.ITF Technology: galvanic insulation protection inputs outputs 6.Universal series power supply
Modular DIN Rail Products offer a wide range of functions to be integrated in electrical installations with significant benefits for the user. It is designed for high level performance and are safe and fast to install. Blue Jay have a complete range of DIN-mounted electricity meters for different applications, together with a wide range of communication options. The meters are quick and easy to install due to their DIN-rail mounting. It is highly accurate, durable, reliable, lower power consumptive, without reversion, creep proof, anti-tanmpering and bilateral recoring with strong overloading capability. It conforms to the related Chinese requirement of GB/T17215.321-2008 and International requirement IEC62053-21 also pass EMC and LVD. Real-time measurement: voltage, current, power, power factor, frequency, Time-of-use metering of forward and reverse active energy, four-quadrant reactive energy; Maximum 4 tariffs; with 1 active pulse output; Automatic settlement function (with a storage of 12 months history records); Optional Event logging function (power on, power down, zero clearing, demand clearing, programming, timing events); Optional 2 channels switching value inputs, 1 electromagnetic relay outputs; Optional 1 channel 12V, 50 mA DC power supply output; Voltage and current ratio range: 0.0000~9999.9999; Abundant programmable alarm outputs; RS-485 supporting Modbus RTU protocol and DL/T645 protocol, self-adaptive; Indication prompts for voltage broken phase, inverse phase sequence, communication and other status; Configurable cyclic display items; Completely enclosed design, dust proof and antifogging.
19D-201 meter is suit for for single-phase measurement, use scenarios such as residential, public facilities, and industrial use. 19D-201 can measure and display various important power parameters, optional communication ports support remote reading and monitoring. Bi-direction metering makes 19D-201 is an excellent choice for solar energy industry. features: -. Detect active/reactive energy, power, frequency, Max demand, voltage, Current and other important power parameters in one screen -. Provide energy import and export measurement (IMP & EXP) -. High light white backlit LCD screen -. Energy pulse output -. RS485 Modbus communication (optional) -. Standard 35mm din rail mounting -. Maximum 100A current access -. Accuracy: Class 1.0s
The MCM400 main for Non - industrial users sub-metering, use ../100mA or 0.333mV CT, split core design easy for install, Din-rail mounting for every style of electrical panel in build. The unit performs real-time metering, measures energy consumption, multi-tariff time-of-use (TOU) and monitors power quality max 4 channels circuit for three phase circuits, with LCD screen and keypad for easy for configuration. RS485 port can send out collected value to remote host. Enable reliable monitoring of building electrical loads with a low installation cost-per-point by combining sub-metering. It is ideal for multi-tenant or departmental metering applications within office towers, condominiums, apartment buildings, shopping centers and other multi-user environments. Features ·Class 0.5 basic parameter and class 1 for active energy ·4 channels three phase metering ·Current measuring .../1A or .../100mA (optional 333mV) ·Standard 35mm - 4 module DIN rail mounting ·Provide RS-485 MODBUS-RTU Communications ·Build in LCD screen, keypad for configuration ·Optional TOU record for each monitor channel ·Accept customization design
BJ-192/193 series especially developed for indication and supervision of the three-phase circuit, replaces an analogical display meter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of single phase and three-phase networks, it is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password. Features: ·Class 0.5(192 series)/0.5S(193 series) electrical parameter measurement ·Current measuring .../5 or .../1 A ·Measurement function cover: Current, Voltage, total three-phase power, power factor, frequency ·RS-485 MODBUS-RTU Communications ·Expandable input / output modules (1 modules) ·ITF Technology: galvanic insulation protection inputs outputs ·Large character LED Screen display ·Optional various install sizes
BJ-192/193 series especially developed for indication and supervision of the three-phase circuit, replaces an analogical display meter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of single phase and three-phase networks, it is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password. Features ·Class 0.5(192 series)/0.5S(193 series) electrical parameter measurement ·Current measuring .../5 or .../1 A ·Measurement function cover: Current, Voltage, total three-phase power, power factor, frequency ·RS-485 MODBUS-RTU Communications ·Expandable input / output modules (1 modules) ·ITF Technology: galvanic insulation protection inputs outputs ·Large character LED Screen display ·Optional various install sizes
Accuracy Measurement :Current Class:0.5 Input Measurement: Wiring: 3-phase 4-wire Ratio value: AC 1A AC5A Overload: Sustained: 1.2times; Instantaneous:10times/5s Power consumption:
Especially developed for indication and supervision of the low-medium voltage three phase electrical network measurement also can be used in DC circuit. It can replaces other analogical panel meter reducing installation manpower and optimizing the used one of spaces in the panel. Features: ·Class 0.5(192 series)/0.5S(193 series) electrical parameter measurement ·Current measuring .../5 or .../1 A ·Measurement function cover: Current, Voltage, total three-phase power, power factor, frequency ·RS-485 MODBUS-RTU Communications ·Expandable input / output modules (1 modules) ·ITF Technology: galvanic insulation protection inputs outputs ·Large character LED Screen display ·Optional various install sizes