FDR-3411 Liquid petroleum products hydrocarbon analyzer Scope Liquid petroleum products hydrocarbon analyzer is based on ASTM D1319 ISO3837 DIN5179 NFM07020 IP131 GB / T11132 standards for design and manufacture. Determination applies to a boiling point below 315 degrees Celsius petroleum hydrocarbon fractions. Features Liquid petroleum hydrocarbon analyzer product safety: 1, a unique convex protection design, high security level, completely isolated from human contact space with ultraviolet light to ensure the safety of the operator. 2, using the current security system, when laboratory voltage instability, the current is too large, can automatically cut off power to protect the safety of personnel and equipment. Liquid petroleum products hydrocarbons analyzer accuracy: 1, the British imported precision column, ensure the accuracy of results, accuracy. 2, using high-precision voltage regulation system to ensure the stability of airflow pressure. 3, supporting the use of imported silica gel staining, the experimental procedure, segmented stained obviously, to ensure the accuracy of test results. Liquid petroleum hydrocarbon analyzer product interoperability: 1, automatic shock system, adjustable oscillation amplitude size 2, independent Friends magnetic slider labeled pointer manner, mark staging easy to operate, convenient 3, Friends customize automatic cleaning system, eliminating manual cleaning of complicated. Technical Parameters 1, the gas flow control valve regulating precision voltage regulator 2, the vibration mode of vibration of the vibrator respectively 3, operating mode double tube; imports Precision adsorption column 4. Analysis of the inner diameter of 1.6 ~ 1.65mm 5, sections within the accuracy of the analysis did not change more than 100mm 0.3mm 6, 365mm wavelength ultraviolet light source, lamp 1220mm
FDR-3571 Octane analyzer (Motor / Research Method) Scope The octane number of gasoline (petrol label) is a contract value, which means the antiknock properties of gasoline, it is the most important quality index of gasoline vehicles, it is one of the core content in oil specification analysis. It is determined by comparing with standard fuel in the standard engine test under specified operating conditions. It can conform to the ASTM D 2699, ISO 5164, ASTM D2700 standards, there are two method: Motor method and Research method. Features 1, the instrument uses a computer touch screen operation, human-friendly communication interface 2, the screen interface can display real-time experimental parameters of the indicators change, at any time monitoring 3, automatic & jog operation adjust the compression ratio, with a limit protection 4, the instrument can use two kinds of operation methods: interpolation and compression ratio method 5, the instrument can automatically generate test reports, and can automatically print the results 6, the instrument is equipped with SE air filtration system, it can provide standard, clean, dry and constant temperature gas; 7, the professional knock signal sensor FDT-DS uses the industry standard, it is more stable and reliable; 8, the instrument is equipped with a special Friend Company's knock detection system, which ensures that the knock signal of the zero, magnification, stable regulation of stability, the repeatability and precision of the instrument are less than 0.2 / R octane number. 9, it uses a magnetic induction ignition, so that the ignition time in the test is more accurate. 10, the instrument is equipped with FAD security protection system, which is used for emergency protection under abnormal conditions to protect the safety of operators; 11, the instrument uses a user-friendly design, customers can also be based on demand, self-matching low-temperature test tank and cooling water circulation system. Technical Parameters 1, measuring range: 50 to 100 octane number; 2, there are two method: Motor method and Research method, it can improve the user's investment effectiveness; 3, cylinder bore: 65mm; 4, the cylinder stroke: 100mm; 5, engine displacement: 0.33L; 6, the compression ratio range: 4: 1 to 12: 1; 7, the engine speed range: 900 ± 9r / min (Motor method) 600 ± 6r / min (Motor method) 8, the machine rated power: 8000W 9, power supply: 380 ± 10% VAC, 50 ± 1Hz 220 ± 10% VAC, 50 ± 1Hz
FDR-3601 Cetane Number and Octane Number analyzer Scope Octane meter meets the requirements of: ASTM D 2699-86, ASTM D 2700-86. Cetane Number meter meets the requirements of: ASTM D 4737-03, ASTM D 613, EN ISO 5165 Measuring principle: By analyzing the characteristics of the insulating charge permeability octane gasoline and diesel fuel cetane number and electromagnetic induction measured out. By measuring the dielectric properties of the sample, with the presence of known parameter memory compared so as to determine the results Features 1, innovative silicon quartz crystal polymer material ring-type detection probe, detection resolution more sensitive and can detect tiny changes in dielectric parameters 2, the annular intensive multi-probe testing, real-time detection of the sample parameters, controlled by strict anti-spreader, the unique design of multi-point dynamic coefficient of self-calibration technology and precision mechanical structure, the result is more accurate 3, innovation introduced the US imports XECOM data processing chip, powerful, fast and accurate processing of data can be stored experimental results 4, display real-time detection of gasoline octane number RON, MON and antiknock index (AKI), as well as pour point diesel fuel cetane index 5, SA intelligent battery management system, long standby time on a single charge can be used for 1000 hours to facilitate customers to carry, Outdoor Detection Technical Parameters 1, test items: gasoline octane number, cetane number and solidifying point 2, detection range: octane: 40-120 (accuracy 0.5), cetane number: 20-100 (accuracy 1) 3, the detection time:
Scope Liquid hydrocarbons traces of water analysis has been connected with the cylinder capillary water bath gasification were analyzed by reduction method. This is a more feasible approach. Flash vaporization injector is our new design, manufacture products, using SCM control, aided by high-precision mass flow meter, able to quickly and accurately control the flow rate and totalized flow, such as olefins successfully solved this trace water analysis a technical problem. And its easy operation, accurate measurement to obtain full recognition by the industry. The instrument used liquid hydrocarbons pretreatment prior to analysis, the liquid sample is converted to other components, constant temperature, constant pressure, can control the flow of gaseous hydrocarbons in order to facilitate the determination. This product is suitable for sample preparation prior to analysis of various items of the following: 1. Ethylene, propylene and butene isomers in trace analysis of water; 2. Various types of olefin polymerization grade or liquefied petroleum gas in trace oxygen, trace sulfur analysis; 3. Various types of polymer grade olefins trace of carbon monoxide, carbon dioxide analysis; 4. Liquid hydrocarbon composition analysis. 5. As for the permanent gases: nitrogen, hydrogen, air and other trace water analysis. Features 1, the use of large-screen LCD, the friendly man-machine communication interface 2, real-time display the contents of the various parameters, user-friendly real-time understanding of experimental data 3, using imported flow meter control program, more accurate experimental data 4, Friends single chip control system, instrumentation stable 5, can be configured to trace moisture, dew point, chromatography and other devices, widely used Technical Parameters 1, the display mode: LCD large-screen LCD displays. 2, Display: instantaneous flow, cumulative flow, instantaneous flow presets, preset totalizer, metal bath gasification chamber temperature, preset temperature. 3, the instantaneous flow rate range: 0-1000SCCM (ml), users can request custom processing. 4, the cumulative flow range: 0-99999SCCM (ml), users can request custom processing. 5, flow measurement accuracy: ± 1.0% (F.S). 6, the gasification chamber temperature range: room temperature -100 . 7, the temperature measurement accuracy: 0.5 . 8, the use of the environment: temperature 5 -35 ; humidity below 75%. 9, the use of power: 220V ± 10%, 50Hz ± 1Hz.
Industrial Measurement Instrument..
I. Introduction SS-600C Hot & Wet Waste Incineration CEMS System developed and produced by Senshang Instruments is to monitor the total air pollutant emissions from stationary sources in waste incineration power plant, to measure SO2, NO, NO2, CO, CO2, HCL, NH3, O2 and H2O, as well as simultaneously to measure particles content, gas flow, gas pressure, gas temperature and so on. The hot-wet sampling system: All components (probe, sample line, pump and analyzer sample cell) in contact with the gas stream are maintained above the dew point of the flue gas to prevent condensation of reactive vapors. This approach does not incorporate a gas cooler. The Hot-Wet sampling approach results in a simple and reliable sampling system with high availability. CEMS consists of 1Gas analysis monitoring system. 2Particles monitoring system. 3Gas temperature/pressure/velocity measurement 4Data Analysis System. II. Application fields It is widely applied to the monitoring of flue gas emissions in ultra-low emission field, thermal power plant, industrial kiln / boiler, cement industry, petroleum industry, waste incineration power generation, hazardous waste incineration and other industries. III. Specifications Measurement items Ranges(can be customized) SO2 0-150-750mg/m3 NO 0-200-1000mg/m3 CO 0-500-2500mg/m3 CO2 0-20%vol-40%vol NH3 0-20-100mg/m3 HCL 0-100-500mg/m3 H2O 0-20%vol-40%vol O2 0-5%vol-25%vol Zero drift ±2%F.S./7d Span drift ±2%F.S./7d Linearity error ±1%F.S. Response time 200s Repeatability 0.5% Resolution 0.005mg/m3 Temperature 0-300 Temperature accuracy ±0.5%F.S. Pressure -5-5KPa(relative) Pressure accuracy ±0.5%F.S. Gas flow 0-30m/s Velocity accuracy ±0.5%F.S. Particles 0-5-25mg/Nm3 Particle max error ±1.5%F.S./7d Particle zero drift ±1.5%F.S./7d Particle span drift ±1.5%F.S. IV. Product feature 1.Maximum 8 gas components measurement, able to measure O2 and H2O(humidity). 2.System cabinet modular design, simple operation, less maintenance. 3.Hot & Wet sampling system, no gas condensation, little SO2 and other gases loss. 4.Adopt ultra-low dust monitor to measure particles. 5.Adopt temp/pressure/velocity all-in-one instrument to measure gas T/P/F. 6.The stability and reliability of the system are higher by PLC design. 7.With anti-corrosive material. 8.With auto purging function.
I. Introduction SS-300-HF Extractive Laser Analysis System adopts TDLAS Tunable diode laser absorption spectroscope to measure HF concentration. It adopts special heated sampling probe which is able to work in high-temperature and high dust conditions, and hot & wet sampling system with little gas loss caused by gas condensing. Compare in-situ type gas analyzer, the extractive system has the advantages of no requirement of installation conditions, easy maintenance, little pollution to mirror, suitable for dirty sampling point with high dust. II. Applications field It is used for online monitoring of organic waste gas emissions and organic waste gas recovery for chemical, printing, pharmaceutical, rubber, spray coating, electronic semiconductors, synthetic leather and so on. III. Specifications Monitoring place Gas component Measurement range aluminum oxide outlet HF 0-20ppm(can be customize) 1.Measurement principleTDLAS 2.Sampling methodHot & Wet extractive sampling 3.Sampling pipe materialSUS316 4.Heated tube diameter: ,¸8,?6 5.Power supply AC220V±10%50/60Hz 6.Power consumptionMax 2000W+50W*heated tube length 7.Calibration periodeach 6 months 8.Analogue output4 - 20mA 9.Max load550Ω 10.Alarm outputgas temperature alarm, gas low pressure, gas over pressure alarm. IV. Features 1.Extractive sampling method 2.Easy calibration and calibration 3.Adopts TLDAS principle, little cross-sensitivity, 4.Laser detector with long lifespan 5.Optional sampling probe calibration function. 6.IP 65 protection class. 7.Adopts hot and wet sampling and gas pretreatment with temperature 190â??, preventing HCL gas loss by condensation. 8.Sampling probe with purging function. 9.With lens blow up function, to prevent it dewing.
I. Introduction SS-300-HCL Extractive Laser Analysis System adopts TDLAS Tunable diode laser absorption spectroscope to measure HF concentration. It adopts special heated sampling probe which is able to work in high-temperature and high dust conditions, and hot & wet sampling system with little gas loss caused by gas condensing. Compare in-situ type gas analyzer, the extractive system has the advantages of no requirement of installation conditions, easy maintenance, little pollution to mirror, suitable for dirty sampling point with high dust. II. Applications field It is used for stack outlet in the waste incineration power plant. III. Specifications Monitoring place Gas component Measurement range Waste incineration stack outlet HCL 0-20ppm(can be customize) 1.Measurement principleTDLAS 2.Sampling methodHot & Wet extractive sampling 3.Sampling pipe materialSUS316 4.Heated tube diameter: 86 5.Power supply AC220V±10%50/60Hz 6.Power consumptionMax 2000W+50W*heated tube length 7.Calibration periodeach 6 months 8.Analogue output4 - 20mA 9.Max load4 - 20mA 550© 10.Alarm outputgas temperature alarm, gas low pressure, gas over pressure alarm. IV. Features 1.Extractive sampling method 2.Easy calibration and calibration 3.Adopts TLDAS principle, little cross-sensitivity, 4.Laser detector with long lifespan 5.Optional sampling probe calibration function. 6.IP 65 protection class. 7.Adopts hot and wet sampling and gas pretreatment with temperature 190, preventing HCL gas loss by condensation. 8.Sampling probe with purging function. With lens blow up function, to prevent it dewing.
I. Introduction SS-300-NH3 Extractive Laser Analysis System adopts TDLAS Tunable diode laser absorption spectroscope to measure HF concentration. It adopts special heated sampling probe which is able to work in high-temperature and high dust conditions, and hot & wet sampling system with little gas loss caused by gas condensing. Compare in-situ type gas analyzer, the extractive system has the advantages of no requirement of installation conditions, easy maintenance, little pollution to mirror, suitable for dirty sampling point with high dust. II. Applications field It is used to monitor NH3 after SNR or SCNR process in the waste incineration plant, power plant and so on. III. Specifications Monitoring place Gas component Measurement range SNR or SCNR stack outlet NH3 0-20ppm(can be customize) 1.Measurement principleTDLAS 2.Sampling methodHot & Wet extractive sampling 3.Sampling pipe materialSUS316 4.Heated tube diameter: ø8Ã?6 5.Power supply AC220V±10%50/60Hz 6.Power consumptionMax 2000W+50W*heated tube length 7.Calibration periodeach 6 months 8.Analogue output4 - 20mA 9.Max load4 - 20mA 550© 10.Alarm outputgas temperature alarm, gas low pressure, gas over pressure alarm. IV. Features 1.Extractive sampling method 2.Easy calibration and calibration 3.Adopts TLDAS principle, little cross-sensitivity, 4.Laser detector with long lifespan 5.Optional sampling probe calibration function. 6.IP 65 protection class. 7.Adopts hot and wet sampling and gas pretreatment with temperature 190, preventing HCL gas loss by condensation. 8.Sampling probe with purging function. 9.With lens blow up function, to prevent it dewing.
I. Introduction The SS-700 process VOCs monitoring system is based on the standards of HJ/T80, HJ/T75, HJ/T76 and other related standards, sampling by extraction method, configuration based on advanced gas chromatography, mass spectrometry separation technologies and hydrogen flame Ionization Detectors (FID), photoionization detectors (PID) to measure the composition of volatile organic gases such as total hydrocarbons (THC), non-methane total hydrocarbons (NMHC), aromatic hydrocarbons, esters, etc. According to the composition and detection requirements in the analysis project, it can be configured to meet the requirements of the analysis project and the frequency of analysis. At the same time, the optimization of instrument configuration can be performed to maximize the use of the instrument and ensure the continuity of sample analysis. reliability. The analysis system fully considers sample gas conditions, dew point and other factors, and specifically designs the pretreatment system to prevent the crystallization of components in sample gas from condensing and changing the concentration of components. The instrument uses special column combination, center cutting and back blowing technology and hydrogen flame ionization detector (FID) technology for detection. The FID Hydrogen Flame Ionization Detector is a typical mass detector that measures the mass change rate of a component in a GC gas. The response value is proportional to the mass of a component entering the detector per unit of time. II. Features 1.The system piping is imported clean stainless steel pipe to reduce adsorption; 2.The system adopts full calibration to eliminate the influence of a small amount of adsorption on the measurement. 3.The analytical method is consistent with the calibration method, and it is detected by GC-FID method. 4.The whole process of high-temperature 180 °C with hot sample transmission, high temperature FID detection, to avoid high-boiling VOCs adsorption and condensation, more accurate measurement; 5.Continuously run maintenance-free design, start-up automatic cycle operation, real online analysis; 6.The whole flow path insulation design is 180°C, no water vapor condensation, to avoid corrosion degradation of parts, suitable for high temperature / high humidity / corrosive conditions; 7.Non-methane total hydrocarbons and simultaneous monitoring of benzene, toluene, xylene and other components III. Application fields It is used for on-line monitoring of organized organic waste gas emissions from chemical, printing, pharmaceutical, rubber, spray coating, electronic semiconductor, synthetic leather, organic waste gas recovery.
I. Introduction SS-2000-HG mercury emission monitoring system for flue gas is a combination of the world's advanced online analytical technology and China's environmental protection monitoring technology. It is based on the company's many years of accumulated experience in the field of gas analysis and adopts multi optical path UV atomic absorption method. The system consists of a sampling unit with heat trace, a valence converter, and an analysis and processing unit. It can realize continuous on-line automatic and accurate measurement of mercury from fixed sources of flue gas. The system uses Cold Vapor Atomic Absorption Spectrometry (CVAAS), which is the most mature and stable analytical method among many mercury analysis methods. This method can only analyze the elemental mercury (Hg0) in the vapor state. CVAAS is based on the principle of selective absorption of ultraviolet light with a wavelength of 253.7 nm using mercury vapor. The low-pressure mercury lamp emits ultraviolet light through a gas chamber filled with sample gas and directly monitors the transmitted light intensity with an optoelectronic receiver to calculate the absorbance. Within a certain concentration range, the mercury concentration is proportional to the absorbance, which is in accordance with Beer-Lambert law. At the same time, oxygen, temperature, pressure, flow rate, humidity and other parameters can be monitored. Charts are generated through the data acquisition and processing system, and data remote transmission interfaces are reserved. The monitoring data can be transmitted to all levels of environmental protection according to the HJ/T212 national standard communication protocol. department. II. Specifications 1. Detection method: Cold Vapor Atomic Absorption (CVAAS) 2. Measurement range: 0-100g/m3, 0-500g/m3 3, detection limit: 0.05g/m3 4, response time T90:
1. Introduction SPF223 sampling probe used in the systems for gas sampling, filtration and heating function, can effectively prevent the condensation of gas samples collected, unique structural design allows for a sampling system is more reliable, more small gas loss rate to ensure system stability and true 2. Features The device and the part of the sample contact are all made of 316L stainless steel material processing, high temperature resistance, strong corrosion resistance. With rain cover can do outdoor work environment. Adopting the isothermal heating body, in the design of compact structure, stable heating temperature. Filter element is made of sintering titanium alloy which has big filter area, high accuracy, small air lock, and can be replaced from the device pulled out completely, simple operation, without tools, greatly shorten the maintenance time, and reduce the labor intensity. Optionally providing a reusable purging / calibration port. Operation is simple, with low temperature alarm. The filter replacement without tools. The switch is convenient, with locked cover. High efficiency filter cleaning system. 3. Specifications Maximum sampling temperature: 300 Maximum working pressure: 6BAR Sampling chamber heating temperature: 140 (factory set, adjustable temperature) Power supply: 220VAC 50/60Hz max 500W Environment temperature: -20~80 Maximum dust load: 100g/m3 Filter accuracy: 5μm (other precision optional, 1-10 m) Filter size: 150*35mm Purging gas interface: OD8/6mm connector Sample gas outlet: OD8/6mm connector The sampling pipe containing: 25 * 1200mmlength is optional Flange size: DN65PN6 The installation of accessories: installation flange & fixing bolts & flange sealed pad
1. Introduction Sampling heated tube is one important part of the environment protection monitoring system, widely used for SCNR, SNR, waste incineration and other emission sampling. 2.Specifications Gas pipe material: PVDF, PTFE, 316L, PFA Black knit anti-scratch layer Air tube size: OD8/6mm,OD6/4mm (optional) Power consumption: 10-100W/M (depending on heating tempeature) Power supply: 220VAC 50HZ Sample gas heated temperature50~220 No breakpoint and cold point all the way Using temperature controller to control heating temperature precisely Excellent heat preservation effect Heated tube external diamete: OD38±2mmOD42±2mm Minimum bending: 0.5m Lowest working temperature: -20 Minimum installation distance: vertical 2m, horizonal 4m.
1. Introduction ECM1/2 series gas condenser is used in the sample gas pretreatment system to remove moisture from the sample. Precise measurement of gas composition means sample gas under dew point can be stable even under bad environment. ECM condenser is to improve measurement precision and life span. 2. Features Perfect design, only one component: compressor Two-loop system Two-loop heating exchanger Constant temperature adjusting system with patent With temperature display Temperature alarm Dew point stability: 0.2 Environment protection refrigeration without Freon 3. Specifications 1.Ambient Temp045 6.Dew point Temp4Factory set 2.Temp Control Accuracy±0.27.Power supply220VAC 50/60Hz 3.Gas Inlet Temp80 8.Voltage300V, fuse10A 4.Gas flow rate300L/h 9.IP gradeIP20 5Warming-up Time15 min 10.Installationwall mounted or 19?�rack
I. Introduction SS-UV-300 flue gas analyzer (low emission monitoring) based on years of experience in research and development of flue gas analyzer, combined with the field practice of nearly ten thousand successful application cases. A number of techniques of the flue gas analyzer (standard form) are upgraded (many times return room to increase gas absorption optical path, and higher accuracy of spectrometer, convection heat transfer core module temperature control, etc.). The analyzer is based on DOAS and chemometric algorithms (PLS), able to measure concentration of gases including SO2, NO2, NO, O2, NH3, Cl2, O3, H2S, CH3I, etc. It has features of high measure accuracy, outstanding reliability, fast response time and wide applicable scope. All indexes reach or exceed those of domestic & foreign similar products, and fully qualify measurement technology index of low emission monitoring occasions. II. Application fields It mainly used for industrial boilers, industrial furnaces emissions monitoring in power plant, iron & steel factory, cement plant and son. III. Specifications Model Standard Low Emission Ultra-low Emission Range 0-300-3000ppm 0-100-300ppm 0-20-100ppm Linearity ±1.5%F.S. Repeatability ±0.5%F.S. Zero Drift ±2%F.S/7d Span Drift ±2%F.S/7d Response time(T90) 10S 30S 30S Working Temp -10-+40 Preheating time No preheating Approx.10 min Sample Gas Interface 6 Sample Gas Flow 0.5-2L/minFluctuation
I. Introduction The analyzer is based on NDIR (Non-dispersive Infrared) technology able to measure concentration of gases including CO,CH4,CO2,SO2,NO etc. It has features of high measure accuracy, outstanding reliability, fast response time and wide applicable scope. All indexes reach or exceed those of domestic & foreign similar products, and fully qualify measurement technology index of low emission monitoring occasions. II. Application fields It mainly used for industrial boilers, industrial furnaces emissions monitoring in power plant, iron & steel factory, cement plant and son.
Temperature calibration instruments, pressure calibration instruments.
Tungsten carbide products, carbide rods, drill bits, DTH drill bit buttons, drag bit buttons, carbide strips, carbide tips, carbide plates.
High speed centrifuge. Low speed centrifuge, prp centrifuge, refrigerated centrifuge, blood bank & blood bag, mini centrifuge, cyto & cytology centrifuge, rotor and tube, blood card & gel card, crude oil test centrifuge, incubator, PRP kits.Clearing agent, transport, shipping
PQWT-L7000 Hand held Outdoor & Indoor underground water leak detection device water pipe damage heating leakage detection Multi-sensor outdoor and indoor pipeline leak detection series, a new generation of intelligent leak detection equipment independently developed by Hunan Puqi Geological Exploration Equipment Institute, specifically for leaking pressure pipes. It is suitable for water leakage detection of outdoor water pipe, fire pipe, heating system, indoor water pipe and underground heating floor pipe. By collecting and analyzing leakage signal, it can locate the water leakage position and solves the problem of pressure pipe water leak. 1. Smart water leak detector built-in high-sensitivity detection sensor. 2. Multi-function leakage detection of indoor and outdoor water pipe. 3. dual mode to locating the most potential leaking area. 4. Different sensors for different detection needs. 5. Locating results picture can be exported for your professional report making. 6. Free online technical guidance and support.